664770
18
Verklein
Vergroot
Pagina terug
1/40
Pagina verder
Business Networking Solution
Installation Guide
JetStream Stackable L2+/L3 Managed Switch
T2700G-28TQ/T3700G-28TQ
IAbout this Installation Guide
About this Installation Guide
This Installation Guide describes the hardware characteristics, installation methods and the points that should
be attended to during the installation. This Installation Guide is structured as follows:
Chapter 1 Introduction.
This chapter describes the external components of the switch.
Chapter 2 Installation.
This chapter illustrates how to install the switch.
Chapter 3 Lightning Protection.
This chapter illustrates how to prevent lightning damage.
Chapter 4 Connection.
This chapter illustrates how to do the physical connection of the switch.
Chapter 5 Configuration.
This chapter instructs you to configure the switch via Web Interface and CLI commands.
Appendix A Troubleshooting.
Appendix B Specifications.
Audience
This Installation Guide is for:
Network Engineer Network Administrator
Conventions
The figures in Chapter 2 to Chapter 5 are for demonstration purposes only. Your switch may differ in
appearance from that depicted.
This Guide uses the specific formats to highlight special messages. The following table lists the notice icons
that are used throughout this guide.
Remind to be careful. A caution indicates a potential which may result in device damage.
Remind to take notice. The note contains the helpful information for a better use of the product.
Related Document
The User Guide and CLI Reference Guide of the product are provided on the resource CD. To obtain the latest
product information, please visit the official website:
http://www.tp-link.com
JetStream Stackable L2+/L3 Managed Switch
II Contents
Contents
Chapter 1 Introduction —————————————— 01
1.1 Product Overview .......................................................................... 01
1.2 Appearance ...................................................................................... 01
Chapter 2 Installation —————————————— 06
2.1 Package Contents ......................................................................... 06
2.2 Safety Precautions ........................................................................ 06
2.3 Installation Tools ............................................................................. 08
2.4 Installation & Connection Flow ................................................. 08
2.5 Product Installation ....................................................................... 10
2.6 Installing & Removing the Power Supply Module ............... 11
2.7 Installing & Removing the Interface Card (Optional) ........ 12
2.8 Stacking Using Interface Card on Rear Panel .................... 13
Chapter 3 Lightning Protection —————————— 15
3.1 Cabling Reasonably....................................................................... 15
3.2 Connect to Ground ........................................................................ 17
3.3 Equipotential Bonding .................................................................. 18
3.4 Use Lightning Arrester ................................................................. 19
Chapter 4 Connection —————————————— 21
4.1 Ethernet Port ................................................................................... 21
4.2 SFP/SFP+ Port ................................................................................. 21
4.3 Console Port .................................................................................... 21
4.4 Verify Installation ............................................................................ 22
4.5 Power on via Power Supply Module ...................................... 22
4.6 Power on via Redundant Power Supply (Optional) ............. 23
4.7 Initialization ....................................................................................... 24
Chapter 5 Conguration ————————————— 25
5.1 Congure the Switch via GUI ..................................................... 25
5.2 Congure the Switch Using CLI ................................................ 26
Appendix A Troubleshooting ——————————— 31
Appendix B Hardware Specications ———————— 32
JetStream Stackable L2+/L3 Managed Switch
01Introduction
Chapter 1 Introduction
1.1 Product Overview
T2700G-28TQ/T3700G-28TQ is TP-Link’s JetStream Stackable L2+/L3 Managed Switch, supporting
up to 4 SFP+ slots. T2700G-28TQ/T3700G-28TQ is ideal for large businesses, campuses or SMB
networks requiring an outstanding, reliable and affordable 10 Gigabit solution.
T2700G-28TQ/T3700G-28TQ supports stacking of up to 8 units, thus providing flexible scalability
and protective redundancy for your networks. Moreover, aiming to better protect your network,
T2700G-28TQ/T3700G-28TQ’s main power is removable. With the help of TP-Link’s RPS,
administrators can easily change its main power if it encounters some problems without shutting
down the switch, thus enabling your network to really enjoy the benefit of uninterrupted operation.
Supporting advanced features such as OSPF, VRRP, IGMP and PIM DM/SM, T3700G-28TQ can fully
implement resilient scalable networks, and T2700G-28TQ can be upgraded with the addition of a
layer 3 license to provide these layer 3 routing features as well.
Note:
Obtain the T2700G-28TQ Layer 3 License T2700G-28TQ-L1000 via the following steps
Buy a license key from a TP-Link authorized distributor.
Go to T2700G-28TQ page on TP-Link website, use the license key together with the switch S/N
and the MAC address for authentication to download the license T2700G-28TQ-L1000.
1.2 Appearance
Front Panel
The front panel of T2700G-28TQ
/
T3700G-28TQ is shown as the following figure.Here we take
T3700G-28TQ as an example.
Figure 1-1 Front Panel
Console Port
LEDs
10/100/1000Mbps
RJ45 Port
Unit ID LED
SFP Port
SFP+ Port
Console Port
Designed to connect with the serial port of a computer or terminal for monitoring and configuring
the switch.
JetStream Stackable L2+/L3 Managed Switch
02
Introduction
LEDs
LED Status Indication
Power
On The switch is powered on
Off The switch is powered off or power supply is abnormal
Flashing Power supply is abnormal
System
Flashing The switch works properly
On/Off The switch works improperly
RPS
On
Green
Both the Power Supply Module and the redundant power supply
work properly
Yellow
The
Power Supply Module
works improperly, but the redundant
power supply works properly
Off The switch is not connected to any redundant power supply
FAN
Green All the fans work properly
Yellow Not all the fans work properly
Master
On
The switch works as master in the stack system, or does not join
any stack system
Off The switch works as slave in the stack system
Module
On(green) An Interface Card is connected to the switch and works properly
Flashing(yellow) An Interface Card is connected to the switch, but works improperly
Off No Interface Card is connected to the switch
Link/Act
(Port 1-24)
Green
On
A 1000Mbps device is connected to the corresponding port, but no
activity
Flashing Data is being transmitted or received
Yellow
On
A 10/100Mbps device is connected to the corresponding port, but
no activity
Flashing Data is being transmitted or received
Off No device is connected to the corresponding port
21F-24F
On
An SFP transceiver is connected to the corresponding port, and it is
connected to a device, but no activity
Flashing
A 1000Mbps device is connected to the corresponding port and
transmitting data
Off
An SFP transceiver is connected to the corresponding port, but it is
not connected to a device, or no SFP transceiver is connected
25, 26
On
An SFP+ transceiver/cable is connected to the corresponding port,
and it is connected to a 10Gbps device, but no activity
Flashing
A 10Gbps device is connected to the corresponding port and
transmitting data
Off
An SFP+ transceiver/cable is connected to the corresponding port,
but it is not connected to a device, or no SFP+ transceiver/cable is
connected
JetStream Stackable L2+/L3 Managed Switch
03Introduction
LED Status Indication
M1,M2
On
An SFP+ transceiver/cable is connected to the corresponding port
of the Interface Card, and it is connected to a 10Gbps device, but no
activity
Flashing
A 10Gbps device is connected to the corresponding port of the
Interface Card and transmitting data
Off
No Interface Card is connected
No SFP+ transceiver/cable is connected to the installed Interface
Card
An SFP+ transceiver/cable is connected to the corresponding port
of the Interface Card, but it is not connected to a device
Port Feature
Model
10/100/1000Mbps
RJ45 Port
Console
Port
1000Mbps
SFP Port
10Gbps SFP+ Port
T2700G-28TQ 24 1 4 (Combo) 4 (2 fixed + 2 optional)
T3700G-28TQ 24 1 4 (Combo) 4 (2 fixed + 2 optional)
10/100/1000Mbps Port
Port 1-24, designed to connect to the device with a bandwidth of 10Mbps, 100Mbps or
1000Mbps. Each has a corresponding Link/Act LED.
SFP Port
Port 21F-24F, designed to install the SFP transceiver. These four SFP transceiver slots are shared
with the associated RJ45 ports. The associated two ports are referred as a “Combo” port, which
means they cannot be used simultaneously, otherwise only RJ45 port works. The SFP ports
support 1000M SFP module connection only.
SFP+ Port
Port 25-26, designed to install the 10Gbps SFP+ transceiver or SFP+ cables. T3700G-28TQ also
provides an interface card slot on the rear panel to install the expansion card (TX432 of TP-Link
for example). If TX432 is installed, you get another two 10Gbps SFP+ ports.
Unit ID LED
Designed to display the stack Unit ID of the switch. For the switch that does not join any stack
system, it displays its default Unit ID. To modify the default unit number, please logon to the GUI
of the switch and go to Stack→Stack Management→Switch Renumber page.
JetStream Stackable L2+/L3 Managed Switch
04
Introduction
Rear Panel
The rear panel of T2700G-28TQ
/
T3700G-28TQ is shown as the following figure.
Figure 1-1 Rear Panel (1)
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
Grounding
Terminal
Power Supply
Module
Interface Card Slot
RPS Input
Connector
Note:
The Interface Card Slot and RPS Input Connector are shipped with protective covers.
Interface Card Slot
Designed to extend the interfaces. You can select a TP-Link Interface Card (TX432 for example)
for your switch if needed. For how to install an Interface Card, please refer to 3.4 Installing &
Removing the Interface Card.
Grounding Terminal
The switch already comes with lightning protection mechanism. You can also ground the switch
through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed information,
please refer to Chapter 4 Lightning Protection.
RPS Input Connector
Designed to connect the RPS (Redundant Power Supply). You can selected an RPS of TP-Link
(RPS150 for example) for your switch if needed. For how to install an RPS, please refer to 5.6
Power on via Redundant Power Supply.
Power Supply Module
The AC Power Supply Module PSM150-AC is installled in the switch. The malfunctioned PSM150-
AC can be replaced with a TP-Link power supply module of the same model. Its input voltage is
100-240V~ 50/60Hz.
The AC Power Supply Module is fully hot swappable, helping to ensure no system interruption
during installation or replacement. For how to install/remove the Power Supply Module, please
refer to 3.3 Installing & Removing the Power Supply Module.
Caution:
Please use the provided power cord.
With all the protective covers removed and the Interface Card (TX432 for example) inserted, the rear
panel of T2700G-28TQ/T3700G-28TQ is shown as the following figure.
JetStream Stackable L2+/L3 Managed Switch
05Introduction
Figure 1-2 Rear Panel (2)
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
JetStream Stackable L2+/L3 Managed Switch
06
Installation
Chapter 2 Installation
2.1 Package Contents
Make sure that the package contains the following items. If any of the listed items is damaged or
missing, please contact your distributor.
One Power Cord and one Console
Cable
One Switch
This Installation Guide
Installation Guide
Business Networking Solution
Two Mounting Brackets and the
Fittings
One Resouce CD
2.2 Safety Precautions
To avoid any device damage and bodily injury caused by improper use, please observe the following
rules.
Safety Precautions
Keep the power off during the installation.
Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and
is well grounded.
Use only the power cord provided with the switch.
Make sure that the supply voltage matches the specifications indicated on the rear panel of the
switch.
Ensure the vent hole is well ventilated and unblocked.
Do not open or remove the cover of the switch.
Before cleaning the device, cut off the power supply. Do not clean it by the waterish cloth, and never
use any other liquid cleaning method.
Site Requirements
Temperature/Humidity
40℃
0℃
JetStream Stackable L2+/L3 Managed Switch
07Installation
Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may
lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high
temperature may accelerate aging of the insulation materials and can thus significantly shorten
the service life of the device. For normal temperature and humidity of the device, please check the
following table.
Environment Temperature Humidity
Operating 0
to 40
10% to 90%RH Non-condensing
Storage -40
to 70
5% to 90%RH Non-condensing
Clearness
The dust accumulated on the switch can be absorbed by static electricity and result in poor contact
of metal contact points. Some measures have been taken for the device to prevent static electricity,
but too strong static electricity can cause deadly damage to the electronic elements on the internal
circuit board. To avoid the effect of static electricity on the operation of the Switch, please attach
much importance to the following items:
Dust the device regularly, and keep the indoor air clean.
Keep the device well grounded and ensure static electricity has been transferred.
Electromagnetic Interference
Electronic elements including capacitance and inductance on the device can be affected by
external interferences, such as conducted emission by capacitance coupling, inductance coupling,
and impedance coupling. To decrease the interferences, please make sure to take the following
measures:
Use the power supply that can effectively filter interference from the power grid.
Keep the device far from high-frequency, strong-current devices, such as radio transmitting station.
Use electromagnetic shielding when necessary.
Lightening Protection
Extremely high voltage currents can be produced instantly when lightning occurs and the air in the
electric discharge path can be instantly heated up to 20,000
. As this instant current is strong
JetStream Stackable L2+/L3 Managed Switch
08
Installation
enough to damage electronic devices, more effective lightning protection measures should be
taken.
Ensure the rack and device are well earthed.
Make sure the power socket has a good contact with the ground.
Keep a reasonable cabling system and avoid induced lightning.
Use the signal SPD (Surge Protective Device) when wiring outdoor.
Note:
For detailed lightning protection measures, please refer to Chapter 3 Lightning Protection.
Installation Site
When installing the device on a rack or a flat workbench, please note the following items:
The rack or workbench is flat and stable, and sturdy enough to support the weight of 5.5kg at least.
The rack or workbench has a good ventilation system. The equipment room is well ventilated.
The rack is well grounded. Keep the power socket less than 1.5 meters away from the device.
2.3 Installation Tools
Phillips screwdriver
ESD-preventive wrist wrap
Cables
Note:
These tools are not provided with our product. If needed, please self purchase them.
2.4 Installation & Connection Flow
The switch provides two interfaces to install the swappable Power Supply Module and Interface
Card, and one interface to connect to Redundant Power Supply. The switch has already been
installed with a Power Supply Module PSM150-AC, and you can also self-purchase the Interface
Card/Redundant Power Supply if needed.
The Installation & Connection flow is shown as the following figure.
JetStream Stackable L2+/L3 Managed Switch
09Installation
Figure 2-1 Installation & Connection Flow
Start
Install the switch to the
specied position
Connect to the ground
Install Interface Card?
No
Ye s
Install the Interface Card
Verify installation
Connect to SFP/SFP+
transceivers and cables
Also power on via
RPS?
Connect to RPS
Ye s
No
Power on via Power
Supply Module
End
Caution:
Make sure the power supply of RPS150 is cut o when connecting or disconnecting RPS150
and the switch, otherwise both RPS150 and the switch may work abnormally or even be
damaged.
Note:
The switch can be powered by the Power Supply Module and Redundant Power Supply
simultaneously or individually. If simultaneously, the Power Supply Module and Redundant
Power Supply together will enable your network to enjoy the benefit of uninterrupted
operation.
JetStream Stackable L2+/L3 Managed Switch
10
Installation
2.5 Product Installation
Desktop Installation
To install the device on the desktop, please follow the steps:
1. Set the device on a flat surface strong enough to support the entire weight of the device with all
fittings.
2. Remove the adhesive backing papers from the rubber feet.
3. Turnover the device and attach the supplied rubber feet to the recessed areas on the bottom at
each corner of the device.
Figure 2-2 Desktop Installation
Feet
Bottom of the Device
Notch
Rack Installation
To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below:
1. Check the grounding and stability of the rack.
2. Secure the supplied rack-mounting brackets to each side of the device with supplied screws, as
illustrated in the following figure.
Figure 2-3 Bracket Installation
Rack-mounting Bracket
Screw
JetStream Stackable L2+/L3 Managed Switch
11Installation
3. After the brackets are attached to the device, use suitable screws (not provided) to secure the
brackets to the rack, as illustrated in the following figure.
Figure 2-4 Rack Installation
Rack
Caution:
Please set 5 to 10cm gaps around the device for air circulation.
Please avoid any heavy thing placed on the device.
Please mount devices in sequence from the bottom to top of the rack and ensure a certain
clearance between devices for the purpose of heat dissipation.
2.6 Installing & Removing the Power Supply Module
The Power Supply Module has already been installed in the switch. Operate as the following steps if
you need to replace the Power Supply Module.
Removing the Power Supply Module
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
grounded.
2. Remove the power cord from the power module and the external power supply system.
3. Use a Phillips screwdriver to loosen the captive screws at both sides of the power supply module
until all spring pressure is released.
4. Pull the handle by one hand towards you along the guide rails, and hold the bottom of the module
by the other hand, until it completely comes out of the switch chassis.
5. In order to better protect the removed power supply module, it is recommended to package it by
an antistatic bag.
6. After removing the PSM150-AC, please install the protective cover as soon as possible to
prevent dust from entering and ensure the normal ventilation in the switch.
Installing the Power Supply Module
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
grounded.
2. If the protective cover has been installed on the power supply module slot of the switch, use
a Phillips screwdriver to loosen the mounting screws of the protective cover and remove the
protective cover, as shown in the following figure.
JetStream Stackable L2+/L3 Managed Switch
12
Installation
Figure 2-5 Removing the Protective Cover
3. Grip the handle of the module by one hand, and hold the bottom of the module by the other hand,
as shown in the following figure. Then gently push the module in along the slot guide rail until the
module is flush with the switch.
Note:
Do not use too much force in the operation. If resistance is encountered or positions of the
power supply module appear larger deection in the operation of installation, you must rst
remove the module and then reinstall the module.
Figure 2-6 Installing the Power Supply Module
Switch
PSM150-AC
Power
PS OK
Fault
4. Tighten the captive screws with a Phillips screwdriver to fix the power supply module in place.
If the screws cannot be tighten, probably because the power supply module is not installed
properly due. Please check carefully.
2.7 Installing & Removing the Interface Card (Optional)
Installing the Interface Card
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
grounded.
2. Use a Phillips screwdriver to loosen the mounting screws of the protective cover on the interface
card slot of the switch and remove the protective cover, similar to the procedure shown in Figure
2-5.
JetStream Stackable L2+/L3 Managed Switch
13Installation
3. Hold the captive screws on the front panel of the interface card, and gently push the interface
card in along the slot guide rail until the interface card is flush with the switch, as shown in the
following figure.
Figure 2-7 Installing the Interface Card
Switch
4. Tighten the captive screws with a Phillips screwdriver to fix the interface card in place.
Removing the Interface Card
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
grounded.
2. Use a Phillips screwdriver to loosen the captive screws at both sides of the interface card until all
spring pressure is released.
3. Pull the interface card towards you along the guide rails, until it completely comes out of the
switch chassis.
4. After removing an interface card, if no new interface card is to be installed, please install the
protective cover as soon as possible to prevent dust from entering and ensure the normal
ventilation in the switch.
Note:
TX432 supports hot plug, so if necessary you can install or remove the interface card when the
switch is operating. However, it is recommended that the power be turned off during installation.
Do not touch the surface-mounted components directly with your hand while the switch is in
operation.
2.8 Stacking Using Interface Card on Rear Panel
You can connect up to 8 switches to form a stack with a single management IP address. Follow
the steps below to connect the switches and configure the stack ports, then the switches will
automatically elect a master unit and establish a stack. Once the stack is established, you can use
any port of any switch in the stack to manage the stack system.
You can use either the SFP+ ports on the front panel or the Interface Card on the rear panel to
create a stack. These two pairs of stack ports cannot be mixedly used in the stack connection.
Here we take stacking using Interface Card for example.
1. Install an Interface Card (TX432 for example) into the Interface Card Slot of each switch, see 3.4
Installing & Removing the Interface Card.
2. Log on to the GUI of each switch, go to Stack
Stack Management
Stack Config page to
enable the stack mode of port M1 and M2 (port 1/1/1 and 1/1/2 on the GUI). Remember to click
Save Cong after the configuration.
JetStream Stackable L2+/L3 Managed Switch
14
Installation
3. Power off the switches, and then connect a 10G SFP+ cable (TXC432-CU1M/TXC432-CU3M of
TP-Link for example) between each pair of Interface Cards among the switches, thus forming a
ring topology as the following figure shows. A ring topology system provides redundancy and
resiliency to the stack.
Figure 2-8 Stacking Using Interface Card
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
SFP+ cable
4. Power on the switches, then the switches will automatically select a master unit. The Master LED
of the selected switch will be on.
5. You can access to any member of the stack via Web/SSH/Telnet/Console connection, thus to
manage all the switches in the stack.
Caution:
In the process of using TP-Link SFP+ Cables, please never bend them into a radius of
45mm (1.77 inch) or less, because it may permanently damage the SFP+ Cables.
JetStream Stackable L2+/L3 Managed Switch
15Lightning Protection
Chapter 3 Lightning Protection
3.1 Cabling Reasonably
In the actual network environment, you may need cable outdoors and indoors, and the requirements
for cabling outdoors and indoors are different. A reasonable cabling system can decrease the
damage of induced lightning to devices.
Note:
It's not recommended using Ethernet cables outdoors. When cabling outdoors, please use a
signal lightning arrester.
Requirements for Cabling Outdoors
Aerial cabling without safeguard is not allowed.
It’s not allowed cabling down the building to connect network devices in different floors.
Outdoor cables should be buried and paved to the indoor through basement. A piece of steel wire
should be paved underground along the pipe and connected to the lightning protection terminal
of the building for shielding. Before connecting the cable to the device, install a signal lightning
arrester on the corresponding port.
When an aerial cable is set up, the cable should be through a metal pipe (15m long at least) before
coming into the building. The two ends of this metal pipe should be grounded. Before connecting
the cable to the device, install a signal lightning arrester on the corresponding port.
It’s not necessary to pave STP cables through pipes. The shielded layer of STP cable should be
well grounded. Before connecting the cable to the device, install a signal lightning arrester on the
corresponding port.
JetStream Stackable L2+/L3 Managed Switch
16
Lightning Protection
Requirements for Cabling Indoors
When cabling indoors, keep a certain distance away from the devices that may cause high-
frequency interferences, such as down-conductor cable, powerline, power transformer and
electromotor.
The main cable should be paved in the metal raceway of the access shaft. When cabling, keep the
loop area formed by the cable itself as small as possible.
Requirements for the distance between Ethernet cable and other pipelines are shown in the table.
Other Pipelines
Ethernet Cable
Min Parallel Net Length L (mm)
Min Parallel-overlapping Net
Height H (mm)
Down-conductor 1000 300
PE 50 20
Service pipe 150 20
Compressed air pipe 150 20
Thermal pipe (not
wrapped)
500 500
Thermal pipe (wrapped) 300 300
Gas pipe 300 20
The two diagrams below demonstrate parallel net length and parallel-overlapping net height.
Note:
The above minimum net length/height is required when metal raceway is not used. If any
requirements cannot be met, you can add a steel tube or metal raceway for shielding.
Requirements for the distance between Ethernet cable and high-power electric devices are in
following tables.
Cable Pave Way
Min Parallel
Length (mm)
<2kVA powerline
Parallel cabling 130
One is in the grounded metal raceway or metal pipe 70
The both are in the grounded metal raceway or metal pipe 10
2 to 5kVA
powerline
Parallel cabling 300
One is in the grounded metal raceway or metal pipe 150
The both are in the grounded metal raceway or metal pipe 80
>5kVA powerline
Parallel cabling 600
One is in the grounded metal raceway or metal pipe 300
The both are in the grounded metal raceway or metal pipe 150
JetStream Stackable L2+/L3 Managed Switch
17Lightning Protection
Device Min Distance (m)
Switch case 1.00
Transformer room 2.00
Elevator tower 2.00
Air-conditioner room 2.00
3.2 Connect to Ground
Connecting the device to ground is to quickly release the lightning over-voltage and over-current of
the device, which is also a necessary measure to protect the body from electric shock.
In different environments, the device may be grounded differently. The following will instruct you to
connect the device to the ground in two ways, connecting to the grounding bar or connecting to the
ground via the power cord. Please connect the device to ground in the optimum way according to
your specific operation environment.
Connecting to the Grounding Bar
If the device is installed in the Equipment Room, where a grounding bar is available, you are
recommended to connect the device to the grounding bar as shown in the following figure.
Figure 3-1 Connecting to the Grounding Bar
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
Switch (Rear Panel)
Ground Cable
Grounding Te rminal
Grounding Bar
Note:
The grounding bar and the ground cable are not provided with our product. If needed, please
self purchase them.
Connecting to the Ground via the Power Supply
If the device is installed in the normal environment, the device can be grounded via the PE (Protecting
Earth) cable of the AC power supply as shown in the following figure.
JetStream Stackable L2+/L3 Managed Switch
18
Lightning Protection
Figure 3-2 Connecting to the Ground
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
Switch (Rear Panel)
AC Power Cord (with PE cable)
Note:
The figure is to illustrate the application and principle. The power plug you get from the package
and the socket in your situation will comply with the regulation in your country, so they may
differ from the figure above.
If you intend to connect the device to the ground via the PE (Protecting Earth) cable of AC
power cord, please make sure the PE (Protecting Earth) cable in the electrical outlet is well
grounded in advance.
3.3 Equipotential Bonding
Equipotential Bonding is the practice of intentionally electrically connecting all earthed systems
to the same grounding grid or connecting the grounding grids of all the earthed systems together
through the ground or overground metal so as to create an earthed equipotential zone. When
lightning occurs, the high voltage produced by lightning current in all systems will meanwhile exist
in their ground cables, and thus all ground cables have the same electrical potential and basically
eliminate the electric strikes between the systems.
The figure below illustrates how to practice equipotential bonding in a network.
JetStream Stackable L2+/L3 Managed Switch
19Lightning Protection
Figure 3-3 Equipotential Bonding
Grounding Terminal Equipotential Bonding Cable
Grounding Bar Ground Cable
When equipotential bonding, please note that the cable should be copper wrapped Kelly with its
area being 6mm
2
at least. The shorter cable the better, and use a grounding bar to establish an
equipotential bonding point.
Note:
The equipotential bonding cable and ground cable are not provided with our product. If
needed, please self purchase it.
3.4 Use Lightning Arrester
Power lightning arrester and signal lightning arrester are used for lighting protection.
Power lightning arrester is used for limiting the voltage surge due to a lightning. If an outdoor AC
power cord should be directly connected to the device, please use a power lightning arrester.
Note:
Power lightning arrester is not provided with our product. If needed, please self purchase it.
Signal lightning arrester is used to protect RJ45 ports of the device from lightning. When cabling
outdoors, please install a signal lightning arrester before connecting the cable to the device.
When purchasing or using a signal lightning arrester, please observe the following rules:
The port rate of the signal lightning arrester should match the rate of the desired port on the device.
If it is not matched, this signal lighting arrester will not work. Purchase a standard lightning arrester.
Install signal lightning arrester near the protected device and connect it to the ground via a shorter
ground cable.
JetStream Stackable L2+/L3 Managed Switch
20
Lightning Protection
Figure 3-4 Equipotential Bonding
Ethernet CableEquipotential Bonding CableGrounding Terminal
Signal Lightning Arrester Device
Note:
Signal lightning arrester is not provided with our product. If needed, please self purchase it.
JetStream Stackable L2+/L3 Managed Switch
21Connection
Chapter 4 Connection
4.1 Ethernet Port
Connect a Ethernet port of the switch to the computer by RJ45 cable as the following figure shows.
Figure 4-1 Connecting the RJ45 Port
RJ45 Cable
RJ45 Port
4.2 SFP/SFP+ Port
Connect an SFP transceiver to the SFP port, or connect an SFP+ transceiver/cable to the SFP+
port. For the switch, if an RJ45 port which is combo with SFP port has a valid link, the associated
SFP port will be disabled and cannot be used.
The following takes SFP Transceiver installation as an example.
Figure 4-2 Inserting the SFP Transceiver
SFP Port
SFP Transceiver
4.3 Console Port
CLI (Command Line Interface) enables you to manage the switch, thus you can load the CLI after
connecting the PCs or Terminals to the console port on the switch via the provided cable.
Connect the console port of the device with your computer by the console cable as the following
figure shown.
JetStream Stackable L2+/L3 Managed Switch
22
Connection
Figure 4-3 Connecting the Console Port
You can also manage the device through the console port, for details please refer to the CLI
Reference Guide on the resource CD.
Note:
The console port is the first port on the left of the front panel.
Please keep the device power off when plugging the console cable.
Do not connect the console port with other ports by RJ45 cable.
4.4 Verify Installation
After completing the installation, please verify the following items:
There are 5~10cm of clearance around the sides of the device for ventilation and the air flow is
adequate.
The voltage of the power supply meets the requirement of the input voltage of the device.
The power socket, device and rack are well grounded.
The device is correctly connected to other network devices.
4.5 Power on via Power Supply Module
After the Power Supply Module (PSM150-AC for example) is installed on the switch, please plug the
female connector of the provided power cord into the power socket of the device, and the male
connector into a power outlet as the following figure shows.
Figure 4-4 Power on via PSM150-AC
Power
PS OK
Fault
PSM150-AC
1
2
JetStream Stackable L2+/L3 Managed Switch
23Connection
Note:
The figure is to illustrate the application and principle. The power cord you get from the
package and the socket in your situation will comply with the regulation in your country, so
they may dier from the gure above.
4.6 Power on via Redundant Power Supply (Optional)
Follow the steps below to connect the Redundant Power Supply (RPS150 for example) to
T3700G-28TQ.
1. Confirm that the power supply of the RPS150 is cut off.
2. Remove the protective covers covering the redundant power socket of RPS150 and the switch,
similar to the procedure shown in .
3. Connect the RPS150 and the switch with DC power cord, as illustrated in Figure 4-5. One end
of the DC power cord is marked by the letters “TOP” and the other end has a positioning card
attached to it. Plug the end with the letters “TOP” into the input socket of the switch with “TOP
facing up and the other end with positioning card into the DC output socket of the RPS150 with
the positioning card facing up.
Figure 4-5 Power on via RPS150
TOP
4
RPS150
Positioning Card
Switch One connector with letters “TOP”
3
4
21
3
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
4. Connect the AC input socket of RPS150 and the power socket with the power cord provided with
RPS150, as shown in Figure 4-6.
JetStream Stackable L2+/L3 Managed Switch
24
Connection
Figure 4-6 Power on RPS150
Caution:
Make sure the power supply of RPS150 is cut off when connecting or disconnecting
RPS150 and the switch, otherwise both RPS150 and the switch may work abnormally or
even be damaged.
4.7 Initialization
After the device is powered on, it begins the Power-On Self-Test. A series of tests run automatically
to ensure the device functions properly. During this time, its LED indicators will respond as follows:
The Power LED indicator will light on all the time.
After keeping off for about one minute, the rest of the LED indicators will flash momentarily, and
then work as the table in 1.2 Appearance shows after the initialization.
JetStream Stackable L2+/L3 Managed Switch
25Conguration
Chapter 5 Configuration
5.1 Configure the Switch via GUI
1. To access the GUI of the switch, open a web browser and type the default management address
http://192.168.0.1 in the address field of the browser, then press the Enter key.
Figure 5-1 Web Browser
Note:
To log on to the GUI of the switch, the IP address of your PC should be set in the same subnet
addresses of the switch. The IP address is 192.168.0.x ("x" is any number from 2 to 254),
Subnet Mask is 255.255.255.0.
2. Enter admin for the default User Name and Password, both in lower case letters. Then click the
Login button or press the Enter key.
Figure 5-2 Login
3. After a successful login, the main page will appear as the following figure, and you can configure
the function by clicking the setup menu on the left side of the screen.
JetStream Stackable L2+/L3 Managed Switch
26
Conguration
Figure 5-3 Main Page of the Switch
5.2 Configure the Switch Using CLI
You can log on to the switch and access the CLI by the following two methods:
Log on to the switch by the console port on the switch.
Log on to the switch remotely by a Telnet or SSH connection through an Ethernet port.
Logon by a Console Port
To log on to the switch by the console port on the switch, please take the following steps:
1. Connect the PCs or Terminals to the console port on the switch by a provided cable.
2. Click Start
All Programs
Accessories
Communications
Hyper Terminal to open the Hyper
Terminal as the following figure shown.
JetStream Stackable L2+/L3 Managed Switch
27Conguration
Figure 5-4 Open Hyper Terminal
3. The Connection Description Window will prompt as Figure 5-5. Enter a name into the Name field
and click OK.
Figure 5-5 Connection Description
4. Select the port to connect in Figure 5-6, and click OK.
JetStream Stackable L2+/L3 Managed Switch
28
Conguration
Figure 5-6 Select the Port to Connect
5. Configure the port selected in the step above as the following Figure 5-7 shown. Configure Bits
per second as 38400, Data bits as 8, Parity as None, Stop bits as 1, Flow control as None, and
then click OK.
Figure 5-7 Port Settings
6. Type in the User name and Password in the Hyper Terminal window, the factory default value for
both of them is admin. The DOS prompt ”Switch>” will appear after pressing the Enter button as
Figure 5-8 shown. It indicates that you can use the CLI now.
JetStream Stackable L2+/L3 Managed Switch
29Conguration
Figure 5-8 Log in to the Switch
Logon by Telnet
To log on to the switch by a Telnet connection, please take the following steps:
1. Firstly CLI commands about configuring Telnet login mode and login authentication information
should be configured through Console connection. For more details please refer to the CLI
Reference Guide on the resource CD. Here we take login local mode as an example.
2. Make sure the switch and the PC are in the same LAN.
3. Click Start and type in cmd in the Search programs and files window and press the Enter button.
Figure 5-9 Open the RUN Window
4. Type telnet 192.168.0.1 in the command prompt shown as Figure 5-6, and press the Enter button.
JetStream Stackable L2+/L3 Managed Switch
30
Conguration
Figure 5-10 Connecting the Switch
5. Type the default user name and password (both of them are admin), then press the Enter button
so as to enter User EXEC Mode.
Figure 5-11 Enter into the User EXEC Mode
For detailed CLI configuration instructions, please refer to the CLI Reference Guide on the resource
CD.
JetStream Stackable L2+/L3 Managed Switch
31Appendix A Troubleshooting
Appendix A Troubleshooting
Q1.
What could I do if I forgot the username and password of the switch?
1. Connect the console port of the PC to the console port of the switch and open hyper terminal.
2. Power off and restart the switch. When you are prompted that “Press CTRL-B to enter the bootUtil” in
the hyper terminal, please press CTRL-B key to enter into bootUtil menu shown as the following figure.
(Please note that there is an extra command for T2700G-28TQ to delete the license file)
3. Enter the number 2 to reset the system. The system will be reset to the factory default settings, and the
default login user name and password are both admin.
Q2.
Why does the Power LED work abnormally?
The Power LED should be lit up when the power system works normally. If the Power LED worked
abnormally, please take the following steps:
1. Make sure that the power cable is connected properly, and the power contact is normal.
2. Make sure the voltage of the power supply meets the requirement of the input voltage of the switch.
Q3.
What could I do if I could not access the web-based conguration page?
You are recommended to check the following items:
1. Check every port LED on the switch and make sure the cable is installed properly.
2. Try another port on the switch and make sure the cable meets the requirement and works normally.
3. Turn off the power. After a while, turn on the power again.
4. Make sure the IP address of your PC is set within the subnet of the switch.
5. If you still cannot access the configuration page, please restore the switch to its factory defaults.
Then the IP address should be set as 192.168.0.x ("x" is any number from 2 to 254) and Subnet Mask as
255.255.255.0.
Q4.
Why does the hyper terminal display abnormally?
Please check as follows:
1. Make sure the power supply is normal and the console cable is properly connected.
2. Check if the console cable is the right type.
3. Ensure the parameters of the hyper terminal are correct: configure Bits per second as 38400, Data bits
as 8, Parity as None, Stop bits as 1, and Flow control as None.
For more troubleshooting help, go to: http://www.tp-link.com/en/support/faq
JetStream Stackable L2+/L3 Managed Switch
32 Appendix B Hardware Specifications
Appendix B Hardware Specifications
Item Content
Standards
IEEE802.3i, IEEE802.3u, IEEE802.3ab, IEEE802.3ad, IEEE802.3ae, IEEE802.3z,
IEEE802.3x, IEEE802.1p, IEEE802.1q, IEEE802.1x, IEEE802.1d, IEEE802.1s, IEEE802.1w
Transmission Medium
10Base-T 2-pair UTP/STP of Cat. 3 or above (maximum 100m)
100Base-TX 2-pair UTP/STP of Cat. 5 or above (maximum 100m)
1000Base-T 4-pair UTP/STP of Cat. 5e and Cat. 6 or above (maximum 100m)
1000Base-SX MMF SFP Module
1000Base-LX MMF or SMF SFP Module
10GBASE-SR MMF SFP+ Transceiver
10GBASE-LR SMF SFP+ Transceiver
Transfer Method Store-and-Forward
MAC Address Learning Automatically learning, automatically aging
Frame Forward Rate
10Base-T: 14881pps/Port
100Base-Tx: 148810pps/Port
1000Base-T: 1488095pps/Port
1000Base-X: 1488095pps/Port
10GBASE-SR:14880952pps/Port
10GBASE-LR:14880952pps/Port
LEDs
Power, System, RPS, FAN, Master, Module, Link/Act, 21F-24F, 25, 26, M1, M2, Unit ID
LED
Operating Temperature 0
to 40
(32
to 104
)
Storage Temperature -40
to 70
(-40
to 158
)
Operating Humidity 10% to 90%RH Non-condensing
Storage Humidity 5% to 90%RH Non-condensing
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user
may be required to take adequate measures.
Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам нормативних
документів та вимогам, що передбачені чинними законодавчими актами України.
Safety Information
When product has power button, the power button is one of the way to shut off the product; when there is no
power button, the only way to completely shut off power is to disconnect the product or the power adapter
from the power source.
Don’t disassemble the product, or make repairs yourself. You run the risk of electric shock and voiding the
limited warranty. If you need service, please contact us.
Avoid water and wet locations.
BSMI Notice
意事
1) 使用原源供只能產品明的使本產品。
2) 清潔本產品之前請先拔掉電源線。請勿使用液體噴霧清潔劑或濕布進行清潔。
3) 注意防潮,請勿將其他液體潑灑到本產品上
4) 開口使用,以確防止開口。
5) 勿將本產品於靠源的地除非有正常的風,否則在密閉置中
6) 請不要私打開機不要嘗試維修本產品,請由授權的專業人士進行此項工作
7) 此為甲類資訊技術設居住環境中使用能會造成射頻擾動,在此種情況使用者會被要求採取某些適當的對策
Industry Canada Statement
CAN ICES-3 (A)/NMB-3(A)
Explanation of the symbols on the product label
Symbol Explanation
AC voltage
Indoor use only
RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic equipment
(WEEE). This means that this product must be handled pursuant to European directive 2012/19/
EU in order to be recycled or dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling organization or to the retailer
when he buys a new electrical or electronic equipment.
Website: http://www.tp-link.com Tel: +86 755 26504400 E-mail: support@tp-link.com
© 2016 TP-Link
7106506849 REV2.0.0
18

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw TP-LINK T3700G-28TQ bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van TP-LINK T3700G-28TQ in de taal/talen: Engels als bijlage per email.

De handleiding is 4,18 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info