TIME BLOCK – Radio-controlled alarm clock
TIME BLOCK – Radio-controlled alarm clock
1312
7.2 Manual alarm setting
Move the FUNCTION switch to AL.SET (ALARM SET).
The hour digit and the alarm symbol (AL) start blinking.
Press UP or DOWN button to adjust hours.
Press MODE button and the setting sequence is shown as follows: Minutes and the snooze
interval, the default setting is 5, from 1 minute to 60. Adjust with UP or DOWN button.
Move the FUNCTION switch to ‘NORMAL’. The alarm setting is finished.
7.3 Activate/deactivate Alarm ON/OFF
Move the ALARM ON/OFF switch to AL.ON (ALARM ON).
AL appears on the display. The alarm is activated.
When the set alarm time is reached the wake-up signal sounds.
Wave hand within 5 inches distance or press the SNOOZE button to activate snooze func-
tion.
For the duration of the pre-set interval function, the alarm will be interrupted up to four
times.
If there is no man-made stop, the clock will alarm lasting 1 minute every snooze interval,
four times totally.
Press any button and the alarm will stop.
Move the ALARM ON/OFF switch to ‘AL.OFF’ (ALARM OFF), the alarm function will stop
working permanently.
7.4 Reading of the temperature, date, the alarm time and the snooze interval
Press the SNOOZE button or wave your hand within 5 inches distance in normal mode to
show the temperature, date, the alarm time and the snooze interval.
7.5 12/24 hour mode
In normal mode, press DOWN button to select 12 (PM appears on the display after 12 h) or
24 hour mode.
7.6 Temperature display
By pressing the UP button the temperature unit can be changed from °C to °F in normal
mode.
8. Brightness
Move the brightness adjusting switch to change brightness in 3 steps (HIGH-MIDDLE-LOW).
9. Reset
If the unit does not work properly use a pin to press RESET button, then the clock will
return to the initial mode.
10. Care and maintenance
Clean it with a soft damp cloth. Do not use solvents or scouring agents. Protect from
moisture.
Keep the instrument in a dry place.
After a test run (11:11 until 00:00 appear on the display) the clock will scan the DCF fre-
quency signal and the DCF symbol flashes on the LCD. When the signal is received success-
fully after 3-10 minutes, the radio-controlled time appears.
Please do not press any keys during signal reception.
If the radio-controlled clock is unable to receive a DCF signal, further attempts will be
made every hour between 2 a.m. and 5 a.m. Therefore no alarm setting is possible
between 2:00 and 2:10, 3:00 and 3:10, 4:00 and 4:10 and 5:00 and 5:10.
Should these attempts fail, a random time will appear on the display and the symbol dis-
appears.
Manual initialization can be helpful. Press MODE button.
In case the clock cannot detect the DCF-signal (for example due to disturbances, transmit-
ting distance, etc.), the time can be set manually. The clock will then work as a normal
quartz clock. (see: Setting of clock and calendar).
Radio-controlled time reception:
The time base for the radio-controlled time is a Caesium Atomic Clock operated by the
Physikalisch Technische Bundesanstalt Braunschweig which has a time deviation of less than
one second in one million years. The time is coded and transmitted from Mainflingen near
Frankfurt via frequency signal DCF-77 (77.5 kHz) and has a transmitting range of approxi-
mately 1,500 km. Your radio-controlled clock receives this signal and converts it to show
the precise time in summer or wintertime. The quality of the reception depends greatly on
the geographic location. In normal cases, there should be no reception problems within a
1,500 km radius around Frankfurt.
Please take note of the following:
Recommended distance to any interfering sources like computer monitors or TV sets is a
minimum of 1.5 - 2 metres.
Within ferro-concrete rooms (basements, superstructures), the received signal is naturally
weakened. In extreme cases, please place the unit close to a window and/or point its front
or back towards the Frankfurt transmitter.
During night-time, the atmospheric disturbances are usually less severe and reception is
possible in most cases. A single daily reception is adequate to keep the accuracy deviation
below 1 second.
7. How to operate
7.1 Manual setting of clock and calendar
Move the FUNCTION switch to ‘T.SET’ (TIME SET).
The hour digits are flashing.
Press UP or DOWN button to adjust hours.
Press MODE button and the setting sequence is shown as follows: Minutes, seconds, year,
month and day. Adjust with UP or DOWN button.
Move the FUNCTION switch to ‘NORMAL’, the time and calendar settings are finished.
The manually set time will be overwritten by the DCF time when the signal is received
successfully.
TFA_No. 60.2508 Anl_08_15 11.08.2015 14:19 Uhr Seite 7
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw TFA 60.2508 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van TFA 60.2508 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 0,27 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info