FAKTUM – Wireless weather station
╞
2120
Measuring range:
Temperature: outdoor: -40°C…+60°C (-40°F...140°F)
Resolution: 0,1°C (0,2°F)
Humidity: 10%…95%
Resolution: 1%
(show HHH if outside range)
(show LLL if outside range)
Atmospheric pressure
Measuring unit: HPa/mBar, inHg or mmHG
Measuring range: 750mb/hPa – 1100 mb/hPa @ 25°C
22.15 – 32.49 inHG
Batteries
Base station: 2 x AA 1.5V LR6 Alkaline batteries
Remote sensor: 2 x AA 1.5V LR6 Alkaline batteries
DECLARATION OF CONFORMITY
Herewith we declare, that this wireless transmission device does comply with the essentials
requirements of R&TTE Directive 1999/5/EC.
A copy of the signed and dated Declaration of Conformity is available on request via info@tfa-
dostmann.de.
TFA Dostmann GmbH & Co. KG, D-97877 Wertheim / www.tfa-dostmann.de
FAKTUM – Wireless weather station
╞
• Check the transmission of 433 MHz signal from the transmitter to the display unit
(transmission range 30 m free field). Within ferro-concrete rooms (basements,
superstructures), the received signal is naturally weakened.
• If necessary choose another position for transmitter and/or display unit.
• Is the transmission successfully, you can wall mount the transmitter by the hanging
hole.
8. Battery replacement
• When the batteries of the main unit or transmitter are used up, the low battery
icon appears beside the time display (main unit) or beside the temperature display
of the appropriate outdoor transmitter.
• If battery change happened on remote sensor side, then the base station must be
powered up again to relocate the transmitter.
• Use alkaline batteries only. Observe correct polarity. Low batteries should be
changed soon to avoid the damage resulting from a leaking battery. Batteries con-
tain harmful acids. Wear protective glasses and gloves when handling damaged
batteries.
Caution:
Please do not dispose of old electronic devices and empty batteries in household
waste. To protect the environment, take them to your retail store or to appropri-
ate collection sites according to national or local regulations.
9. Maintenance
• Keep it in a dry place.
• Do not expose the instrument to extreme temperatures, vibration or shock.
• Clean it with a soft damp cloth. Do not use solvents or scouring agents.
• Avoid placing the instrument near interference sources/metal frames such as com-
puter or TV sets.
• If the unit does not work properly, change the battery.
10. Liability disclaimer
• The product is not a toy. Keep it out of reach of children.
• The product is not to be used for medical purpose or for public information, but is
determined for home use only.
• The specifications of this product may change without prior notice.
• No part of this manual may be reproduced without written consent of TFA Dost-
mann.
• Improper use or unauthorized opening of housing will mean the loss of warranty.
11. Specifications
Transmission distance in open field: 30 meter max.
Frequency: 433 MHz
Measuring interval sensor: 47 sec
main unit: 10 sec
Measuring unit: °C/°F
Temperature range indoor: -5°C...+50°C (23°F....122°F)
Resolution: 0.1°C (0.2°F)
Humidity: 10%…95%
Resolution: 1%
TFA_No. 35.1101 Anleitung 02.02.2010 10:06 Uhr Seite 11