576890
2
Verklein
Vergroot
Pagina terug
1/6
Pagina verder
Digital control thermometer
Digital control thermometer
Thank you for choosing this instrument from TFA.
1. Before you use it
Please be sure to read the instruction manual carefully.
Following the instruction manual for use will prevent damage to the device and loss
of your statutory rights arising from defects due to incorrect use. We shall not be
liable for any damage occurring as a result of not following these instructions. Like-
wise, we take no responsibility for any incorrect readings and for any consequences
which may result from them.
Please take particular note of the safety advice!
Please keep this instruction manual for future reference.
2. Field of operation
Temperature measurement with waterproof cable sensor for food (in accordance with
HACCP and EN13485), handcraft, laboratories, industry, agriculture and hobbies.
3. For your safety
The product is exclusively intended for the field of application described above. The
product should only be used as described within these instructions.
Unauthorised repairs, modifications or changes to the product are prohibited.
The product is not be used for medical purpose or for public information, but is
intended only for home use.
Caution!
ƽ Risk of injury:
Keep this instrument and the battery out of reach of children.
Batteries must not be thrown into the fire, short-circuited, taken apart or recharged.
Risk of explosion!
Batteries can be fatal if swallowed. If a battery has been swallowed, get medical assis-
tance immediately.
Batteries contain harmful acids. Low batteries should be changed as soon as possible to
prevent damage caused by a leaking battery.
Wear chemical-resistant protective gloves and glasses when handling leaked batteries.
ƽ Important information on product safety!
Do not place the unit near extreme temperatures, vibration or shock.
Only the probe is heat resistant up to 70 °C.
Do not immerse the display unit into water. Water can penetrate and cause malfunc-
tion.
4. Components
Display (LCD)
1 Battery low 4 Higher Alarm
2 Alarm symbol 5 Lower Alarm
3 Buzzer Alarm Flashing Icon
5. Installation
Pull off the protection foil on the display. Open the battery cover on the backside of the
instrument by opening the two little screws next to the magnet by a screw driver,
remove the insulation strip and tighten the cover again. The unit is now ready for use.
6. Operation
6.1 Temperature indication
The present temperature in °C or °F measured by the cable sensor is indicated on the
display. Press the +1-switch to change from °C to °F readout.
6.2 ON/OFF button
Press “ON/OFF”-button to switch the instrument on and off. Settings are preserved, for
measurements and alerting the instrument must be switched on.
6.3 Hold/max-min-function
When pressing the “MAX/MIN”-button, the present display is held (HOLD).
Pressing again the “MAX/MIN”-button, the display shows the maximum temperature
since the last reset (MAX).
When pressing the “MAX/MIN”-button again, the display shows the minimum temper-
ature since the last reset (MIN).
To go back to the present temperature display, press the “MAX/MIN”-button once
more.
To reset the maximum and minimum values, hold the “MAX/MIN”-button for 3 sec-
onds, while MAX or MIN is indicated ( ---).
6.4 Upper limit and lower limit temperature alert
To set an upper temperature limit, that means when passing the temperature an alarm
is beeping, press the “AL SET”-button in normal mode. The upper temperature limit
is shown and it is flashing. Set the desired temperature by pressing the +1-button.
Hold and press the button for a fast count. Now you can activate (alarm symbol
appears) or deactivate (alarm symbol disappears) the alarm pressing “MAX/MIN”-
button. Confirm by pressing the “AL SET”-button.
The lower temperature limit
is shown and it is flashing. To set a lower temperature
limit, that means when falling below the temperature an alarm is beeping, press +1-
button. Hold and press the button for a fast count. Now you can activate or deactivate
the alarm pressing “MAX/MIN-button”. Confirm by pressing the “AL SET”-button.
After setting temperature alarm the symbols
▲▼
show, if an upper or lower tempera-
ture alarm is acti-vated.
When passing or falling below the selected temperature limit an alarm signal will
sound for 1 minute, the buzzer alarm icon and the corresponding arrow
or
will
flash. The alarm and the buzzer alarm icon can be turned off manually by pressing any
button.
When temperature is again within the selected limits the alarm signal will stop (within
1 min.) and the buzzer alarm flashing icon disappears. The arrow keeps on flashing
showing that the temperature was higher/lower than the preset value at least once in
the past. Press +1- button and the arrow will stop flashing.
7. Care and maintenance
Clean it with a soft damp cloth. Do not use solvents or scouring agents.
Remove the battery if you do not use the product for a lengthy period.
Keep the instrument in a dry place.
8. Battery replacement
For a long battery life, it is recommend to press the “ON/OFF” button to switch the
instrument off when not in use.
When the battery is used up, the low battery icon appears.
Open the battery cover on the backside of the instrument, insert a new battery CR2032
3V Lithium and tighten the cover again.
9. Troubleshooting
Problems Solutions
No display Ensure battery polarity is correct (+ pole above)
Change battery
Switch on the instrument (ON)
Incorrect display Check the position of the cable sensor
Change battery
10. Waste disposal
This product has been manufactured using high-grade materials and components which
can be recycled and reused.
Never dispose empty batteries and rechargeable batteries in household
waste.
As a consumer, you are legally required to take them to your retail store or
to appropriate collection sites depending to national or local regulations in
order to protect the environment.
The symbols for the heavy metals contained are: Cd=cadmium, Hg=mercu-
ry, Pb=lead.
This instrument is labelled in accordance with the EU Waste Electrical and
Electronic Equipment Directive (WEEE).
Please do not dispose of this instrument in household waste. The user is
obligated to take end-of-life devices to a designated collection point for the
disposal of electrical and electronic equipment, in order to ensure environ-
mentally-compatible disposal.
11. Specifications
Measuring range temperature: -40°C ...+70°C (-40°F...+158°F)
Precision : ±0.5°C @ -20…+25°C,
otherwise ±1°C
Cable: approx. 3m
Resolution: 0.1°C
Protection class: IP 65
Power consumption: 1x CR2032 3V Lithium Button cell battery (included)
Housing dimension: 87 x 17 (29) x 52 (57) mm
Weight: 79 g (only instrument)
This product fulfills the guidelines according to EN 13485.
Suitability: S, T (Stockage, Transport)
Location: A
Accuracy class: 1
Measuring range: -40°C…+70C
In accordance with EN 13485, this instrument is subject to regular inspections as per EN
13486 (recommendation: yearly).
TFA Dostmann GmbH & Co. KG, Zum Ottersberg 12, D-97877 Wertheim.
No part of this manual may be reproduced without written consent of TFA Dostmann. The
technical data are correct at the time of going to print and may change without prior
notice.
www.tfa-dostmann.de 10/12
Kat. Nr. 30.1034
Bedienungsanleitung
Instruction manual
LCD
TFA_No. 30.1034_Anleit_D_GB 30.10.2012 14:17 Uhr Seite 2
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw TFA 30.1034 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van TFA 30.1034 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 0,17 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info