794260
27
Verklein
Vergroot
Pagina terug
1/32
Pagina verder
Model:
TCLSS09 (2.5kW Cooling / 2.6kW Heating)
TCLSS12(3.2kW Cooling / 3.2kW Heating)
TCLSS18 (5.0kW Cooling / 5.2kW Heating)
TCLSS24(7.0kW Cooling / 7.5kW Heating)
TCLSS28 (7.8kW Cooling / 8.0kW Heating)
CONTENTS
SAFETY PRECAUTIONS
NAMES OF PARTS
INDOOR UNIT DISPLAY
OPERATING INSTRUCTIONS
PROTECTION
INSTALLATION MANUAL
MAINTENANCE
TROUBLESHOOTING
EMERGENCY FUNCTION & AUTO-RESTART FUNCTION
REMOTE CONTROLLER
....................................................................................................1
.................................................................................................................4
.........................................................................................................5
..............................................6
........................................................................................................7
.............................................................................................10
.........................................................................................................................15
....................................................................................................16
....................................................................................................................25
..........................................................................................................26
1
During the installation of the indoor and outd-
oor units the access to the working area should
be forbidden to children.
Unforeseeable accidents could happen.
Make sure that the base of the outdoor unit is
firmly fixed.
Check that air cannot enter the refrigerant sys-
tem and check for refrigerant leaks when mo-
ving the air conditioner.
SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER
Carry out a test cycle after installing the air co-
nditioner and record the operating data.
The ratings of the fuse installed in the built in-
control unit are T 5A / 250V .
The user must protect the indoor unit with a
fuse of suitable capacity for the maximum in-
put current or with another overload protection
device.
Check that the socket is suitable for the plug ,
otherwise have the socket changed.
Do not install the appliance at a distance of
less than 50 cm from inflammable substances
(alcohol, etc.) Or from pressurised containers
(e.g. spray cans).
If the appliance is used in areas without the
possibility of ventilation, precautions must be
taken to prevent any leaks of refrigerant gas
from remaining in the environment and creat-
ing a danger of fire
Read this guide before installing and using the
appliance.
The appliance must be fitted with means for
disconnection from the supply mains having
a contact separation in all poles that provide
full disconnection under overvoltage
category III conditions, and these means
must be incorporated in the fixed wiring in
accordance with the wiring rules.
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that
they do not play with the appliance.
The air conditioner must be installed by
professional or qualified persons.
The appliance must be installed in accordance
with national wiring regulations.
2
SAFETY RULES AND RECOMMENDATIONS FOR THE USER
Do not try to install the conditioner alone;
always contact specialized technical personnel.
Cleaning and maintenance must be carried out
by specialised technical personnel. In any case
disconnect the appliance from the mains elect-
ricity supply before carrying out any cleaning
or maintenance.
Ensure that the mains voltage corresponds to
that stamped on the rating plate. Keep the swi-
tch or power plug clean. Insert the power plug
correctly and firmly into the socket , thereby
avoiding the risk of electric shock or fire due
to insufficient contact.
Do not pull out the plug to switch off the app-
liance when it is in operation, since this could
create a spark and cause a fire, etc.
If the appliance gives off smoke or there is a
smell of burning, immediately cut off the pow
er supply and contact the Service Centre.
Have repairs carried out only by an authoris-
ed Service Centre of the manufacturer . Inco-
rrect repair could expose the user to the risk
of electric shock, etc.
The prolonged use of the device in such
conditions could cause fire or electrocution.
Never remain directly exposed to the flow of
cold air for a long time. The direct and prolo-
nged exposition to cold air could be dangero-
us for your health .Particular care should be
taken in the rooms where there are children ,
old or sick people.
This appliance has been made for air conditi-
oning domestic environments and must not be
used for any other purpose , such as for drying
clothes, cooling food, etc.
The packaging materials are recyclable and
should be disposed of in the separate waste
bins . Take the air conditioner at the end of its
useful life to a special waste collection centre
for disposal.
Only use the air conditioner as instructed in
this booklet.These instructions are not intend-
ed to cover every possible condition and situ-
ation.As with any electrical household applia-
nce, common sense and caution are therefore
always recommended for installation , operat-
ion and maintenance.
Always use the appliance with the air filter
mounted . The use of the conditioner without
air filter could cause an excessive accumulation
of dust or waste on the inner parts of the device
with possible subsequent failures.
Unhook the automatic switch if you foresee
not to use the device for a long time.
The airflow direction must be properly adjus-
ted.
The user is responsible for having the appliance
installed by a qualified technician , who must
check that it is earthed in accordance with curr-
ent legislation and insert a thermomagnetic cir-
cuit breaker.
Ensure that the appliance is disconnected from
the power supply when it will remain inoperat-
ive for a long period or before carrying out
any cleaning or maintenance.
Selecting the most suitable temperature can pr-
event damage to the appliance.
The flaps must be directed downwards in
the heating mode and upwards in the cooling
mode.
The batteries in remote controller must be
recycled or disposed of properly.
Disposal of Scrap Batteries --- Please disca-
rd the batteries as sorted municipal waste at
the accessible collection point.
3
SAFETY RULES AND PROHIBITIONS
Do not bend , tug or compress the power cord
since this could damage it. Electrical shocks or
fire are probably due to a damaged power cord.
Specialised technical personnel only must repl-
ace a damaged power cord.
Do not use extensions or power board.
Do not touch the appliance when barefoot or
parts of the body are wet or damp.
Do not obstruct the air inlet or outlet of the in-
door or the outdoor unit.
The obstruction of these openings causes a re-
duction in the operative efficiency of the con-
ditioner with possible consequent failures or
damages.
In no way alter the characteristics of the appli-
ance.
Do not install the appliance in environments
where the air could contain gas , oil or sulphur
or near sources of heat.
Do not climb onto or place any heavy or hot
objects on top of the appliance.
Do not leave windows or doors open for long
when the air conditioner is operating.
Do not direct the airflow onto plants or anim-
als.
A long direct exposition to the flow of cold
air of the conditioner could have negative
effects on plants and animals.
Do not put the conditioner in contact with
water.
The electrical insulation could be damaged
and thus causing electrocution.
Do not climb onto or place any objects on the
outdoor unit
Never insert a stick or similar object into the
appliance. It could cause injury.
Children should be supervised to ensure
that they do not play with the appliance.
If the supply cord is damaged, it must be
replaced by the manufacturer,its service
agent or similarly qualified persons in
order to avoid a hazard.
NAMES OF PARTS
No. Description
1
2
Front panel
Air filter
Optional filter (if installed)
3
Terminal block cover
4
Emergency button
5
6
LED Display
Signal receiver
7
Airflow direction louver
8Deflectors
9
Remote controller
10
Note: the above figures are only intended to be a
simple diagram of the appliance and may not
correspond to the appearance of the units that
have been purchased.
No. Description
13 Air outlet grille
Terminal block cover
14
gas valve
15
liquid valve
16
11
Indoor unit rating label ( )Stick position optional
17
Outdoor unit rating label
12
Ionizer (if installed) generator
13
15
16
17
INDOOR UNIT
4
OUTDOOR UNIT
12-3
6
4-5
9
11 8
10 7
14
DISPLAY HEALTHY
3D
ON/OFF
SWING
FAN
TIMERSUPER
SLEEPMODE
ECO
CLOCK
12
INDOOR UNIT
OUTDOOR UNIT
10
INSTALLATION MANUAL---Information for the installer
CABLE WIRES SPECIFICATION
24
MODEL capacity (Btu/h)
5k 7k 9k 12k 15/18k 22/24k
28/30k/36k
Power supply cable
Connection supply cable
N
L
E
1
2
3
N
L
2
1.0mm
2
1.0mm
2
1.0mm
2
1.0mm
2
0.75mm
2
0.75mm
2
0.75mm
2
1.0mm 2
1.0mm 2
1.5mm
2
2.5mm 2
4.0mm
2
(1.5mm)
2
1.0mm
2
1.0mm 2
1.0mm 2
(1.5mm)
2
1.0mm
2
1.0mm 2
1.0mm 2
(1.5mm)
2
1.0mm
2
1.0mm 2
1.0mm 2
(1.5mm)
2
1.0mm
2
0.75mm 2
0.75mm
2
0.75mm 2
0.75mm
2
0.75mm
2
0.75mm
2
1.5mm
2
1.5mm
2
1.5mm
2
0.75mm
2
0.75mm
2
0.75mm 2
0.75mm 2
0.75mm 2
0.75mm
2
0.75mm 2
0.75mm
2
0.75mm 2
0.75mm
2
0.75mm 2
0.75mm
2
0.75mm 2
0.75mm
2
0.75mm 2
0.75mm
2
0.75mm 2
0.75mm
sectional area
9k 12k 18/22k 24k
Power supply cable
Connection supply cable
N
L
E
1
N
L
sectional area
2
1.5mm 2
2.5mm
2
(1.5mm)
2
1.0mm
2
(1.5mm)
2
1.0mm
2
(1.5mm)
2
1.0mm
2
(1.5mm)
2
1.0mm
2
1.5mm
2
1.5mm
2
1.5mm
2
(1.5mm)
2
1.0mm
2
(1.5mm)
2
1.0mm
2
(1.5mm)
2
1.0mm
2
0.75mm
2
(1.5mm)
2
1.0mm
2
(1.5mm)
2
1.0mm 2
1.5mm
2
(1.5mm)
2
1.0mm
INVERTER TYPE
MODEL capacity (Btu/h)
(AWG16)
AWG18 (AWG16)
AWG18 AWG16
2
1.5mm 2
2.5mm
2
(1.5mm)
2
1.0mm
2
(1.5mm)
2
1.0mm
(AWG16)
AWG18 (AWG16)
AWG18 AWG16
2
1.5mm 2
2.5mm
2
(1.5mm)
2
1.0mm
2
(1.5mm)
2
1.0mm
(AWG16)
AWG18 (AWG16)
AWG18 AWG16
AWG18
(AWG16)
AWG18
AWG18 AWG18 AWG16 AWG14
2
1.0mm 2
1.0mm 2
1.0mm 2
1.5mm
2
2.5mm 2
4.0mm
2
(1.5mm)
2
1.0mm
AWG18
(AWG16)
AWG18
AWG18 AWG18 AWG16 AWG14
2
1.0mm 2
1.0mm 2
1.0mm 2
1.5mm
2
2.5mm 2
4.0mm
2
(1.5mm)
2
1.0mm
AWG18
(AWG16)
AWG18
AWG18 AWG18 AWG16 AWG14
AWG14
AWG14
AWG14
AWG12
AWG12
AWG12
2
0.75mm
2
0.75mm
2
0.75mm
H05RN-F
H05RN-F
H05RN-F
220V 7K , 9K , 12K 15K , 16K , 18K , 22K , 24K , 30K air conditioner indoor unit fuse parameter is 50T, 3.15A
110V 7K , 9K 12k air conditioner indoor unit fuse parameter is 50T, 3.15A,
125V 7K , 9K , 12K air conditioner outdoor unit fuse parameter is 61T, 15A
250V 18K , 22K , 24K air conditioner outdoor unit fuse parameter is 65TS, 25A
27

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw TCL TCLSS12 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van TCL TCLSS12 in de taal/talen: Engels als bijlage per email.

De handleiding is 2.82 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info