User’s manual
IMPORTANT SAFETY INSTRUCTIONS
1 Read these instructions.
2 Keep these instructions.
3 Heed all warnings.
4 Follow all instructions.
5 Do not use this apparatus near water.
6 Clean only with dry cloth.
7 Do not block any ventilation openings. Install in
accordance with the manufacturer's instructions.
8 Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including amplifiers)
that produce heat.
9 Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. If the provided plug
does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10 Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the point
where they exit from the apparatus.
11 Only use attachments/accessories specified by the
manufacturer.
12 Use only with the cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the
cart/apparatus combination to avoid injury from tip-over.
13 Unplug this apparatus during lightning storms or when
unused for long periods of time.
14 Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been damaged
in anyway, such as cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
Warning!
To reduce the risk of fire or electric shock, do not expose
this apparatus to dripping or splashing and ensure that no
objects filled with liquids, such as vases, are placed on the
equipment.
This apparatus must be earthed.
Use a three wire grounding type line cord like the one
supplied with the product.
Be advised that different operating voltages require the use
of different types of line cord and attachment plugs.
Check the voltage in your area and use the correct type. See
table below:
To completely disconnect this equipment from the AC
mains, disconnect the power supply cord plug from the AC
receptacle.
The mains plug of the power supply cord shall remain readily
operable
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the product.
The lightning flash with an arrowhead symbol
within an equilateral triangle, is intended to alert
the user to the presence of uninsulated
"dangerous voltage" within the product's
enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
This equipment should be installed near the socket outlet
and disconnection of the device should be easily accessible.
Do not install in a confined space.
Do not open the unit - risk of electric shock inside.
Caution:
You are cautioned that any change or modifications not
expressly approved in this manual could void your authority
to operate this equipment.
Service
There are no user-serviceable parts inside.
All service must be performed by qualified personnel.
Voltage Line plug according to standard
110-125V UL817 and CSA C22.2 no 42.
220-230V CEE 7 page VII, SR section
107-2-D1/IEC 83 page C4.
240V BS 1363 of 1984.
Specification for 13A fused
plugs and switched and
switched socket outlets.
IMPORTANT SAFETY INSTRUCTIONS
EMC / EMI.
This equipment has been tested and found to comply with
the limits for a Class B Digital device, pursuant to part 15 of
the FCC rules.
These limits are designed to provide reasonable protection
against harmful interference in residential installations. This
equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on. The user is encouraged to try to
correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the
equipment and receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
For the customers in Canada:
This Class B digital apparatus complies with Canadian ICES-
003.
Cet appareil numérique de la classe B est conforme à la
norme NMB-003 du Canada.
Certificate Of Conformity
TC Electronic A/S, Sindalsvej 34, 8240 Risskov, Denmark,
hereby declares on its own responsibility that the
following product:
VoiceWorksPlus
Harmony | Modeling | Effects Processor
- is covered by this certificate and marked with CE-label
conforms with following standards:
EN 60065 Safety requirements for mains
(IEC 60065) operated electronic and related
apparatus for household and similar general use
EN 55103-1 Product family standard for
audio,video, audio-visual and entertainment lighting
control apparatus for professional use. Part 1: Emission.
EN 55103-2 Product family standard for audio,
video, audio-visual and entertainment lighting control
apparatus for professional use. Part 2: Immunity.
With reference to regulations in following directives:
73/23/EEC, 89/336/EEC
Issued in Risskov, 03 - 2004
Mads Peter Lübeck
Chief Executive Officer
INTRODUCTION
Thank you for purchasing VoiceWorksPlus, a vocal
processing powerhouse designed to enable the singing
musician to produce captivating vocals in recording and
live performance. Everything from exciting harmony
parts to evocative character impersonations to simply
better vocal sound is possible with VoiceWorksPlus.
Features:
Generates up to 4 additional harmony “voices” with a
variety of musical input methods
Exclusive TC-Helicon pitch, timing and energy
humanization that effectively mimics singing groups
Vocal modeling effects such as breathiness, growl, and
resonance help create alternate voice “personalities”
Vocal pitch correction block
TC Electronic Reverb, chorus, tap delay effects & more
Distortion, megaphone and telephone effects
3 band EQ, compressor and gate
Handy top level edit knobs
100 Factory / 100 User presets and MIDI control
Microphone preamp, stereo analog and digital
input/output
Optional footswitch control
We update our manuals and various support materials
on a regular basis. For the most up to date information
we encourage you to visit our website at:
www.tc-helicon.com
We hope you and your fans enjoy VoiceWorksPlus,
The TC-Helicon Team
3
TABLE OF CONTENTS
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Front Panel Descriptions . . . . . . . . . . . . . . . . . . . . . . . . .5
Back Panel Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . .8
Quick Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Editing Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Harmony Editing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Harmony Background and Tips . . . . . . . . . . . . . . . . . . . .19
Lead Voice Model Editing . . . . . . . . . . . . . . . . . . . . . . . . .24
Pitch Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Reverb, Mod and Delay Editing . . . . . . . . . . . . . . . . . . .30
The Transducer Block . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
The Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . .37
Signal Flow Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
MIDI Implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Manual version 1.2
Software version 1.01
VoiceWorksPlus
English Version
Prod No.: 606131011
VoiceWorksPlus can be thought of as a rack full of
vocal processing in one single rackspace unit with a
couple of specialty effects thrown in for good measure.
The specialty effects, vocal harmony and modeling,
offer you the advantages of:
- Producing rich harmony vocals and doubling from
one voice during live performance
- Saving time when recording vocal harmonies
- Changing the characteristics of your singing voice
with modeling to create interesting vocal hooks
and effects
The remaining processing blocks, including the
multieffects, dynamics and EQ add to your list of
advantages allowing you to :
- Make your live performances sound more like a
fully-produced CD
- Make your recordings sound more professional
- Save time preparing for mixes or performances by
using factory presets and settings
See the diagram at right for a rough algorithmic path
overview.
PRODUCT OVERVIEW
4
FRONT PANEL DESCRIPTIONS
1. Power Switch
Press to turn the unit on or off.As the unit shuts down,
it saves any setup data you may have changed.
2.Alphanumeric LED display
This 15 segment LED display shows the current preset
number whenever the EDIT and SETUP buttons are
not lit. There are dots on the bottom line indicating
whether the current preset is in the Factory or User
bank. The legend below the display indicates which dot
represents which bank. When you press the EDIT or
SETUP buttons, this display shows a letter and a
number making up the address of the current edit
screen.
3. Metering LED displays
There are several conditions indicated by these LEDs
and they are described in the following paragraphs.
Output Clip
This LED will light showing the output of the product
has clipped due to internal level overload, possibly
causing audible distortion. This LED can light even
though the Input Clip LED has not. This is because
VoiceWorksPlus has effect blocks such as Harmony for
example, that can potentially add significant level to the
input signal.
Input Clip
Steady flickering of this LED with audio input shows
that the level of the signal received at the input to
VoiceWorksPlus is too high given the input sensitivity
setting. To correct this, reduce the send level to
VoiceWorksPlus from the upstream mixer or enter the
Setup menu to reduce the LineSens (Line input
sensitivity).
Input LED Stack
These LEDs allow you to gauge how much level to
send to VoiceWorksPlus from your mixer. They use
PPM (Peak Program Meter) weighting which is a way to
view signal level when using digital processors. The
range shows logarithmic steps down from 0 dB which
is the maximum allowable level. It's important to adjust
the send level from your mixer within the proper range
shown by these meters. Sending too little audio signal
level contributes to noise buildup and unsatisfactory
performance of the voice algorithms. Too much input
signal level causes distortion. If your mixer is sending
its maximum level and these meters show insufficient
level, or vice versa, you can adjust the Input Sensitivity
setting by pressing the SETUP button and entering the
Setup menu.
MIDI IN indicator LED
This will light to confirm the MIDI data is received by
VoiceWorksPlus on the correct MIDI channel. To
ensure that it will respond correctly to the incoming
data, check to see that both your sending device and
VoiceWorksPlus are set to the same MIDI channel.
4. Main LCD display
During normal operation (none of the EDIT, SETUP or
STORE buttons are pressed), this display shows the
name of the current preset on the top line and the
main harmony or modeling parameter values on the
lower line. A slight turn of any of the soft knobs will
change the display to show master mix levels. While
the mix levels are shown, the four soft knobs allow
editing of the mix.After a few seconds the display will
revert to preset name. After the EDIT, SETUP or
STORE buttons have been pressed, this display shows
up to four editing parameters on the top line and their
associated values on the bottom. After a parameter
value has been changed, an asterisk (*) will be shown
to the left of the name when you return to normal
operation. This is to warn that you will lose any
changes should you recall another preset unless it is
saved first.
1 2 3 4
5
6
5. Soft knobs overview
During normal operation these controls act as a mixer,
allowing you to quickly modify the global mix levels
without entering an edit menu. Moving any of the
knobs will momentarily switch the LCD display so that
it shows the levels before reverting to the preset name
and the information line.When either the EDIT, SETUP
or STORE buttons have been pressed, the soft knobs
control up to four editing functions from left to right
in the editing menus.
Global LEAD LEVEL control
This adjusts the level of the "Lead" voice. This path is
called Lead because it has no Harmony or Modeling
processing applied. Note that this path may have Pitch
Correction enabled if the Correction switch from the
upper switch group is lit.
Global HARMONY / MODEL LEVEL control
Adjusts the overall level of any harmony voices that are
turned on or the level of the modeled voice depending
on which configuration is chosen in the current preset.
Make sure the Harmony / Model switch above this
knob is lit or this control will have no effect.
Global FX LEVEL control
Adjusts the master level of the Mod , Delay, Reverb
and Transducer effects blocks for all presets. The
individual effects blocks have their own level
adjustment controls which may be turned down
preventing you hearing them when you turn the FX
Level control. Make sure the FX switch above this knob
is lit or the FX Level control will have no effect.
Global OUTPUT LEVEL control
This control raises, lowers or mutes the master output
of VoiceWorksPlus.
6. Block On/Off button group
These 3 buttons allow selective muting of blocks in
each preset to simplify editing.
HARMONY / MODEL button
When this LED is lit, the current preset is configured
to produce harmony or a modeling effect. You can
press this button to disable the current effect and see
what other effects are enabled in the preset.
CORRECTION button
This button allows you to quickly disable pitch
correction when needed.If this button is off in a preset,
turning it on will enable pitch correction with default
settings which may or may not be optimum for your
purpose. In this case you can edit the settings in the
Edit menu at location C0.
FX button
If the FX (effects) button is lit, pressing it will mute all
signal from the Mod, Delay and Reverb blocks . The
Transducer effect will not be muted. If this button is
not lit in a preset, pressing it will patch in a default
effects setting.
7. Mode Button Group
EDIT button
Press this button to enter and exit the preset Edit
menu. All settings relating to the current preset only
are accessed here. The last edit screen you accessed
with the Data Wheel is remembered to reduce time
required to locate specific edit menus.
SETUP button
Press this button to access all of the global audio
settings, MIDI functions, the EQ and Dynamics
processors and preset backup and restore. Press again
to return to recalling presets.
7
5
6 98
FRONT PANEL DESCRIPTIONS
34
IO to I4 - Inputs/Output
I0: Input sensitivity
MicSens (Microphone sensitivity) This allows further
adjustment of microphone input sensitivity. Normal is
best for the majority of microphones. However, the
Low and High settings can be useful for extra high
output or extra low level microphones.
LineSens (Line input sensitivity) Sets the Line input
sensitivity, or maximum input level from 0dBu to 24dBu
to match with your mixer. The factory default setting
of 15dBu is an average output level from most mixers.
Adjust this up or down when you see the input meters
consistently low or in the red.
I1: Digital input gain
Digital In Gain: Here the digital in signal can be
attenuated to reduce clipping. 0dB is unity and is the
ideal setting.
I2: Input source and clock settings
Input: Here you select the Analog or Digital input.
Selecting Analog input will use the input selected via
the front panel (Mic or Line). Digital input will use the
rear S/PDIF connectors. The digital output is always
available regardless of this setting.
ClockSrc: (Clock source) This sets the audio clock
frequency and source. If using the analog inputs, this
parameter is best set to Int(ernal) 44.1. If you are using
the digital input you should set this to sync to
Ext(ernal) clock. If no valid clock signal is recieved via
the digital inputs, an error message will be shown.
I3: Output and bypass mode
Output: Collapses all stereo output to mono if desired.
BypMode: (Bypass mode) This sets how
VoiceWorksPlus operates in Bypass. The Stage setting
preserves any EQ and Dynamics settings you have set
and matches the level of the Dry voice.
The Studio setting removes all effect processing
including the EQ and Dynamics and outputs the lead
signal at full level to the output.
I4: Input on/off controls
Dry VoiceIn: Setting this to Off removes the dry lead
audio from the signal path in any presets that mix in
your dry voice. This is useful when using
VoiceWorksPlus on an auxilliary mixer send and want
100% wet output.
AuxIn: (Auxilliary input) Setting this to Off removes
the dry Aux Input audio from the signal path. This
allows VoiceWorksPlus to produce only 100% wet
effects when receiving an effects send from a mixing
board into the Aux Input. (Only available in analog
input mode if Mic Input is selected)
Q0 to Q4 - EQ/Compressor
The EQ and compressor in VoiceWorksPlus are global
meaning that all presets will be affected once either of
the compressor or EQ has been activated. Be careful
when adjusting these parameters because feedback is
more likely.
Q0: EQ and compressor assignment
DynAssign: (Dynmics assignment) This allows you to
assign dynamic processing (compressor and gate) to
the lead voice, harmony/model voices, both lead and
harmony/model voices or neither. Hint: assigning only
to the lead voice with a medium compressor setting
(threshold: -15dB, ratio:2:1) keeps the lead voice a
consistent volume but keeps harmony levels following
the singers level. This gives control of harmony levels
with mic technique.
EQAssign: (EQ assignment) This allows assignment of
the three band EQ to the lead voice, harmony/model
voices, both lead and harmony/model voices or neither.
Q1: Compressor controls
The compressor in VoiceWorksPlus has automatic
makeup gain to a maximum of +20dB.This means that
the volume level of the signal will be increased for most
volume levels of input with the compressor enabled.
Threshold: Sets threshold at which the compressor
becomes active level from 0 to -60 dB. A moderate
setting of -6 to -15 works well.
Ratio: Sets your compression ratio range from 1.12:1
to 64:1. This sets how much level reduction occurs
once the input signal reaches the threshold you have
set.
Q2: EQ settings
VoiceWorksPlus has a flexible 3 band EQ with
frequency-adjustable high and low shelving bands and a
fully parametric band with Q, frequency and gain
controls.
LoShelf: Sets the knee frequency for the low frequency
shelving boost or cut. Frequency Range: 80Hz to
16kHz
THE SETUP MENU
38

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw TC Helicon Voiceworks Plus bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van TC Helicon Voiceworks Plus in de taal/talen: Engels als bijlage per email.

De handleiding is 0,99 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van TC Helicon Voiceworks Plus

TC Helicon Voiceworks Plus Gebruiksaanwijzing - Deutsch - 44 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info