549839
6
Verklein
Vergroot
Pagina terug
1/13
Pagina verder
Dynamic
Read and retain these instructions for future reference
Dynamic 7.0 plus
Dynamic 9.0 plus
SPECIFICATION
Model no. Dynamic 7.0 plus Dynamic 9.0 plus
Cooling capacity 7000 BTU/h 8500 BTU/h
Power/Ampere consumption for
cooling*
780 W / 3,5 A 930 W / 4,3 A
Air volume (max. speed) 260m
3
300m
3
Humidity removal capacity 20 l / day 24 l / day
Power supply 230V/50Hz/1phase
Recommended room size 10~18m
2
14~24m
2
Compressor rotary
Power supply 230V/50Hz/1phase
Refrigerant R 410 A
Refrigerant load* 350 g 390 g
Fan speed 2
Timer 1 ~ 12 hours
Working temperature, thermostat 18 ~ 32
o
C
Net Weight 20,5 kg 21,5 kg
Dimension 310 x 348 x 710 mm (WxDxH)
REMARK:
The data marked with '*' may vary for technical reasons: for greater
precision, please refer to the rating label placed at the back of the unit.
BEFORE USE
CAUTION !
This appliance is not intended for use by persons
(including children) with reduced physical,
sensory or mental capabilities, or lack of
experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Make sure the unit is connected to an earthed,
power supply of the correct rating. (Please refer
to the rating label locating at the back side of the
unit.)
Do not use this product for functions other than
those described in this instruction manual.
Always place the unit on a stable ground base.
(FIG.1)
The unit must always stand or be transported in a
vertical position.
Do not cover or obstruct the appliance’s inlet and
outlet Grilles. (FIG.2)
Do not use the product in a wet room, such as
bathroom or laundry room. (FIG.3)
Keep an air path of at least 36 cm from walls,
furniture and curtains. (FIG.4)
Do not sit or place objects on the unit.
Do not touch the unit with wet or damp hands or
when barefoot.
Do not l
et chemical substances come into contact
with the unit.
Do not use the product in the presence of
inflammable substance or vapour such as
alcohol, insecticides, petrol etc.
Never use the plug to start and stop the unit.
Always use the switch on the control panel.
Turn off the product when not in use.
Always remove the mains plug before carrying
out maintenance.
BEFORE USE
If the electrical socket is different from the plug, have a professionally qualified electrician replace the
socket with a suitable one. Avoid the use of adapter plugs, multiple sockets and / or extension leads. If
their use is necessary, ensure they conform to current safety regulation.
Do not pull the supply cable or place it near a source of heat: always unroll it completely to avoid
dangerous overheating.
If the supply cord is damaged, it must be replaced by the service agent or a similarly qualified person, in
order to avoid a hazard.
Never use the unit without the filter.
Especially, younger, elder, and disabled people are often not aware of the danger that might occur from
the usage of electrical appliances. Therefore, the product should never be used without supervision.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY, IF THE ABOVE INSTRUCTIONS ARE
NOT FOLLOWED.
Energy Save
Please use the unit in the recommended room size.
Do not locate air conditioner where furniture or other objects can obstruct the air flow.
Keep blinds / curtains closed during the sunniest part of the day.
Close the fireplace damper, floor and / or wall registers, so cool air does not escape through the
chimney or duct work.
Keep the filters clean.
Set the unit to maximum cooling and high speed ventilation for the initial start up, then adjust the
unit to a comfortable setting.
Parts
Front Back
1. Display window
2. Control panel
3. Buttons
4. Air outlet
5. Carrying handle
6. Caster
Accessories
13. Outward adaptor - for insertion over hose
and into foam strip (or into hole in the
wall/window).
14. Exhaust hose
15. Foam strip - for filling the open window
space and with hole for connection to
exhaust hose.
16. Foam strip - for filling the open window
space
17. Round cap for filling the hole in
wall/window.
18. Drain tube for continuous
drainage
19. Active carbon filter
20. Remote control
7. Cord storage
8. Air filter
9. Air inlet
10. Exhaust air outlet
11. Air inlet
12. Water stopper/drainage point
INSTALLATION
Installation of the exhaust pipe
This unit is a PORTABLE AIR CONDITIONER. It can be moved from room to room, so the cooling can
follow you anywhere. The mounting is easy, beneath a window or wall. Please refer to either of the
following steps:
1.
Using the foam strips
Connect the supplied foam strips with the exhaust pipe to let hot air flow to the outside. If
necessary cut off the extra part to fit the window.
Feed exhaust hose through the foam strip and insert strip into window gaps as shown and
slide window across so that foam is held securely. This technique may also be used for sash
windows. Note: Take care to maintain protection against intruders.
2. Using the adaptor
Cut a 130mm diameter hole in the wall or window.
Feed exhaust hose through the window or wall and attach the threaded adaptor from the
outside as shown.
When not in use, plug the hole with the cover provided.
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Suntec Wellness Dynamic 7.0 Plus bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Suntec Wellness Dynamic 7.0 Plus in de taal/talen: Engels als bijlage per email.

De handleiding is 0,38 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info