SPECIFICATION
Model no. Dynamic 6.0 plus Dynamic 8.0 plus
Cooling capacity 6000 BTU/h 8000 BTU/h
Power/Ampere consumption for
cooling*
680 W / 3,0 A 800 W / 3.6 A
Air volume (max. speed) 260m
3
300m
3
Humidity removal capacity 20 l / day 24 l / day
Power supply 230V/50Hz/1phase
Recommended room size 10~18m
2
14~14m
2
Compressor rotary
Power supply 230V/50Hz/1phase
Refrigerant R 410 A
Refrigerant load* 340 g 380 g
Fan speed 2
Timer 1 ~ 8 hours
Working temperature, thermostat 18 ~ 32
o
C
Net Weight 20,5 kg 24,5 kg
Dimension 310 x 248 x 710 mm (WxDxH)
REMARK:
1. The data marked with '*' may vary for technical reasons: for greater
precision, please refer to the rating label placed at the back of the unit.
29
BEFORE USE
CAUTION !
Make sure the unit is connected to a earthed, power
supply
of the correct rating. (Please refer to the rating
label locating at the back side of the unit.)
Do not use this product for functions other than those
described in this instruction manual.
Always place the unit on a stable ground base.
(FIG.1)
The unit must always stand or be transported in a
vertical position.
Do not cover or obstruct the appliance’s inlet and
outlet Grilles. (FIG.2)
Do not use the product in a wet room, such as
bathroom or laundry room. (FIG.3)
Keep an air path of at least 50 cm from walls,
furniture and curtains. (FIG.4)
Do not sit or place objects on the unit.
Do not touch the unit with wet or damp hands or
when barefoot.
Do not let chemical substances come into contact
with the unit.
Do not use the product in the presence of
inflammable substance or vapour such as alcohol,
insecticides, petrol etc.
Never use the plug to start and stop the unit. Always
use the switch on the control panel.
Turn off the product when not in use.
Always remove the mains plug before carrying out
maintenance.
30
29
BEFORE USE
If the electrical socket is different from the plug, have a professionally qualified electrician replace the socket with
a suitable one. Avoid the use of adapter plugs, multiple sockets and / or extension leads. If their use is necessary,
ensure they conform to current safety regulation.
Do not pull the supply cable or place it near a source of heat: always unroll it completely to avoid dangerous
overheating.
If the supply cord is damaged, it must be replaced by the service agent or a similarly qualified person, in order to
avoid a hazard.
Never use the unit without the filter.
Especially, younger, elder, and disabled people are often not aware of the danger that might occur from the usage
of electrical appliances. Therefore, the product should never be used without supervision.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY, IF THE ABOVE INSTRUCTIONS ARE
NOT FOLLOWED.
Energy Save
Please use the unit in the recommended room size.
Do not locate air conditioner where furniture or other objects can obstruct the air flow.
Keep blinds / curtains closed during the sunniest part of the day.
Close the fireplace damper, floor and / or wall registers, so cool air does not escape through the chimney or duct
work.
Keep the filters clean.
Set the unit to maximum cooling and high speed ventilation for the initial start up, then adjust the unit to a
comfortable setting.
31
Parts
Front Back
1. Display window
2. Control panel
3. Buttons
4. Air outlet
5. Carrying handle
6. Caster
Accessories
13. Outward adaptor - for insertion over hose
and into foam strip (or into hole in the
wall/window).
14. Exhaust hose
15. Foam strip - for filling the open window
space and with hole for connection to
exhaust hose.
16. Foam strip - for filling the open
window space
17. Round cap for filling the hole in
wall/window.
18. Drain tube for continuous
drainage
19. Active carbon filter
20. Remote control
7. Cord storage
8. Air filter
9. Air inlet
10. Exhaust air outlet
11. Air inlet
12. Water stopper/drainage point
32
INSTALLATION
Installation of the exhaust pipe
This unit is a PORTABLE AIR CONDITIONER. It can be moved from room to room, so the cooling can follow you
anywhere. The mounting is easy, beneath a window or wall. Please refer to either of the following steps:
1. Using the foam strips
Connect the supplied foam strips with the exhaust pipe to let hot air flow to the outside. If necessary cut off the
extra part to fit the window.
Feed exhaust hose through the foam strip and insert strip into window gaps as shown and slide window across so
that foam is held securely. This technique may also be used for sash windows. Note: Take care to maintain
protection against intruders.
2. Using the adaptor
Cut a 130mm diameter hole in the wall or window.
Feed exhaust hose through the window or wall and attach the threaded adaptor from the outside as shown.
When not in use, plug the hole with the cover provided.
33
INSTALLATION
Mounting of the exhaust pipe
1. Use only the hose provided and clip
exhaust hose to the back of the air
conditioner. It is recommended that
you use the hose in the shortest
possible length.
2. Avoid kinks and bends in the exhaust
hose as this will cause expelled moist
air to build up causing the unit to
overheat and shut down.
WARNING!
The length of the exhaust pipe is specially
designed according to the specification of
this product. Do not replace or prolong it
with your own private hose as this could
cause the unit to mal-function.
Handling of electronic type
FIG. 8
FIG.9
FIG.10
34
Control panel
,
Fig. 12
1. ON/OFF (power) button
2. Timer
3. ‘Temperature up' button
4. Indicator for compressor
5. “Water Full” indicator
6. ‘Temperature down' button
7. Speed (ventilation)button
8. Mode (function) option button
9. Fan mode indicator
10. Cooling mode indicator
11. Automatic mode indicator
12. High ventilation indicator
13. Low ventilation indicator
14. Display window
15. Receiver for remote control
16. Timer operation indicator
Turning ON/OFF
1. Press ON/OFF button, the unit will start automatically. If the ambient temperature is
- higher than 23
o
C, the unit will work in cooling model.
- higher than 20
o
C but below or equal to 23
o
C, the unit will work in ventilation model.
- below 20
o
C, the unit will work in heating function (This is for cooling & heating models
only.)
2. Indicators of the functions in progress come on at the same time. *NOTE! The display
window shows the ambient room temperature from 0
o
C to 50
o
C
3. To turn the unit off, press ON/OFF button again.
Setting mode/function
Press MODE button to select required working mode: automatic, cooling or fan. The
indicator of your selected mode comes on.
Setting temperature
1. Press 'Temperature up' or 'Temperature down' button to regulate the temperature you
desired.
2. The display window will show the temperature you set as you press 'Temperature up' or
'Temperature down' button. Otherwise, it will always show the ambient temperature.
3. The pre-setting temperature of this machine is: 24
o
C for cooling
Setting ventilation speed
35
1. Press SPEED button to choose the ventilation speed you need, high or low. The indicator
of high or low ventilation will light on at the same time.
2. If the unit is in AUTO mode, it will choose the ventilation speed automatically according to
the ambient temperature (the related indicators will light on), at this time, the speed
switch is invalid.
Setting timer
1. Press TIMER button to set the operating hours you desired (1 to 12 hours, the timer
indicator will light on). When the set time has been reached, the machine will turn
off automatically. The display window will show the hour(s) you set as you press
TIMER button. If the timer button is not pressed, the unit will work continuously.
2. By the machine to work. For example, if you press the timer to '2', the unit will work
automatically after 2 hours.
All the above functions can also be performed with the supplied
remote control.
This remote control requires 2 pcs AAA batteries
to operate.
Regulating air flow direction
Turn the roller on the air vent in
horizontal way to control the air flow
direction.
36
NOTICE !
1. To prolong the compressor's life, after switch-off of the unit, please wait for 3
minutes (at least) before re-switch.
2. The cooling system will switch off if the ambient temperature is lower than the set one. The
ventilation, however, keeps working on the set level. If the ambient temperature rises above
the selected level, the cooling will return to work.
Installation of the carbon filter
1. Remove the filter frame from the unit.
2. Remove the active carbon filter from its plastic bag.
3. Insert the active carbon filter into the back of the unit.
4. Re-fit the filter frame inside the unit.
DRAINAGE
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Suntec Wellness Dynamic 6.0 Plus bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Suntec Wellness Dynamic 6.0 Plus in de taal/talen: Engels als bijlage per email.

De handleiding is 0,35 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info