549845
14
Verklein
Vergroot
Pagina terug
1/15
Pagina verder
Advance MM
Advance 2.9 MM plus Advance 3.5 MM plus
Read and retain these instructions for future reference
SPECIFICATION
Model no.
Advance 2.9MM
plus
Advance 3.5MM
plus
Cooling capacity
10000 BTU/hr
2520 Kcal/hr
2930 watts
12000 BTU/hr
2770 Kcal/hr
3516 watts
Power/Ampere consumption for cooling*
1180W/ 5.3A
1500W/ 6.7A
Air volume (max. speed) 420m
3
/h 500m
3
/h
Humidity removal capacity 1,8 L/h 2,0 L/h
Power supply 230V/50Hz/1phase
Compressor rotary
Refrigerant R410A
Refrigerant load* 525g 530g
Fan speed 3
Timer electronic switch 124 hours
Working temperature
18 ~ 32
o
C
Exhaust pipe Ø 142X1500mm
Net Weight 31 kgs 32 kgs
Dimension 450X365X825 mm (WxDxH)
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they do
not play with the appliance.
2
BEFORE USE
GENERAL SAFETY
ONLY USE IN THE UPRIGHT POSITION
ON A FLAT LEVEL SURFACE AND AT
LEAST 36cm FROM ANY OBJECTS (Fig
1 & 4).
DO NOT PLACE OBJECTS ON THE
UNIT OR RESTRICT AIR INLET /
OUTLET (FIG. 2).
CLOSELY SUPERVISE ANY CHILDREN
AND PETS WHEN UNIT IS IN USE.
ELECTRICAL SAFETY
FOR INDOOR USE ONLY.
SWITCH OFF AND UNPLUG WHEN
NOT IN USE.
DO NOT USE IN HUMID OR WET
ENVIRONMENTS (FIG 3)
DO NOT PULL THE UNIT ALONG BY
THE CORD.
IF THE SUPPLY CORD IS DAMAGED,
IT MUST BE REPLACED BY AN
ELECTRICIAN OR SIMILARLY
QUALIFIED PERSON, TO AVOID
HAZARD.
FOR MAXIMUM EFFICENCY
Do not exceed the recommended room
size
Close doors and windows
Keep curtains of blinds closed during
the sunniest part of the day
Keep filters clean
Once room has reached the desired
conditions, reduce temperature and
ventilation settings
FIG. 1
FIG. 2
FIG.3
FIG.4
3
14
19
18
17
13
16
12
15
10
11
PARTS
Front Back
1. Control Panel
2. Air outlet
3. Carrying handle
4. Caster
5. Air filter
6. Air inlet
7. Exhaust air outlet
8. Cord storage
9. Water stopper / drainage point
Accessories
10. Inward adaptor, piece 2 - for
insertion over hose and
connection with piece 1.
11. Inward adaptor, piece 1 - for
connection with piece 2 and into
back of the air conditioner.
12. Outward adaptor - for insertion
over hose and into foam strip (or
into hole in the wall/window).
13. Round cap for filling the hole in
wall/window.
14. Exhaust hose.
15. Foam strip - for filling the open
window space and with hole for
connection to exhaust hose.
16. Foam strip - for filling the open
window space
17. Drain tube for continuous
drainage
18. Active carbon filter
19. Remote control (optional)
4
INSTALLATION
Installation of the exhaust pipe
The unit is a portable air conditioner that may be moved from room to room.
1. Using the foam strips
FIG.5
Offer foam strips to the window gap and cut to size if necessary.
Feed exhaust hose through the foam strip and insert strip into window gaps as
shown and slide window across so that foam is held securely. This technique
may also be used for sash windows. Note: Take care to maintain protection
against intruders
2. Using the adaptor
FIG.6
FIG.7
Cut a 136mm diameter hole in the wall or window.
Feed exhaust hose through the window or wall and attach the threaded adaptor
from the outside as shown.
When not in use, plug the hole with the cover provided.
5
Foam strips
Wall or Window
Outward adaptor
Mounting of the exhaust pipe
Use only the hose
provided and clip
exhaust hose and unit
adaptor to the back of
the air conditioner
Avoid kinks and bends
in the exhaust hose as
this will cause expelled
moist air to build up
causing the unit to
overheat and shut
down. Fig 8 & 9 show
correct position
The hose may be
extended from 300mm
to 1500mm but for
maximum efficiency use
the shortest length
possible.
WARNING!
The length of the exhaust pipe is
specially designed according to
the specification of this product.
Do not replace or prolong it with
your own private hose as this
could cause the unit to mal-
function.
6
FIG.8
FIG.9
FIG.10
FIG.11
Installation of the carbon
filter
1. Remove the filter frame
from the unit.
2. Separate the filter fixer
from the filter frame.
3. Remove the active
carbon filter from its
plastic bag.
4. Insert the active carbon
filter into the filter frame.
5. Fix the filter by
reassembling the fixer
onto the filter frame.
6. Re-fit the filter frame
inside the unit.
7
OPERATION for electronic type
Control panel
FIG.12
1. ON/OFF (power) button
2. Sign for dehumidification/water full
3. Sign for fan (ventilation)
4. Mode button
5. Sign for heat function
6. Sign for Centigrade or Fahrenheit
(please refer to the real unit you
purchased)
7. Swing button
8. Sign for sleep function
9. Sleep function button
10. “Temperature down”button
11. Room temperature display
12. Receiver for remote control
13. Timer display
14. “Temperature up”button
15. Timer
16. Sign for TiO2/ionizer (only for the unit with
TiO2/ionizer)
17. TiO2/ionizer button (only for the unit with
TiO2/ionizer function)
18. Fan speed display
19. Sign for automatic function
20. Fan speed button
21. Sign for cooling function
Turning ON/OFF
1. Press ON/OFF button, the unit will start automatically. If the ambient temperature is
higher than 23
o
C, the unit will work in cooling model.
higher than 20
o
C but below or equal to 23
o
C, the unit will work in ventilation
model.
below 20
o
C, the unit will work in heating function (This is for cooling & heating
models only.),
8
2. Indicators of the functions in progress come on at the same time. *NOTE! The
display window shows the ambient room temperature from 0
o
C to 50
o
C
3. To turn the unit off, press ON/OFF button again.
Setting mode/function
Press MODE button to select required working mode: automatic, cooling, fan,
dehumidification or heating, (Heating is only available for heating & cooling models.)
Sign of your selected mode comes on.
Setting temperature
1. Press 'Temperature up' or 'Temperature down' button to regulate the temperature
you desired.
2. The display window will show the temperature you set as you press 'Temperature
up' or 'Temperature down' button. Otherwise, it will always show the ambient
temperature.
3.
The pre-setting temperature of this machine is: 24
o
C for cooling, 20
o
C for heating.
Setting ventilation speed
1. Press SPEED button to choose the ventilation speed you need, high, medium or
low. The sign of high, low or medium ventilation will light on at the same time.
2. If the unit is in AUTO mode, it will choose the ventilation speed automatically
according to the ambient temperature.
Setting timer
1. Press TIMER button to set the operating hours you desired (1 to 24 hours, the sign
of timer will light on). When the set time has been reached, the machine will turn off
automatically. The LCD will show the hour(s) you set as you press TIMER button. If
the timer button is not pressed, the unit will work continuously.
2. By pressing the timer but without turning on the other functions, you can PRE-SET
the time for the machine to work. For example, if you press the timer to '2', the unit
will work automatically after 2 hours.
Sleep function
1. In cooling mode, by pressing the SLEEP button, the set temperature will increase
1
o
C at the 1st hour, another 1
o
C at the second hour, then keeps at that
temperature.
2. In heat mode, by pressing the SLEEP button, the set temperature will descend 1
o
C
at the 1st hour, another 1
o
C at the second hour, then keeps at that temperature.
9
3. In sleep mode, the ventilation will keep at low speed. Re-press the SLEEP button,
the setting temperature and ventilation speed will return to the pre-selected one.
4. The unit will shut down automatically after the SLEEP function running for 12 hours.
5. Please note, the sleep function is not available while the machine is working
in ventilation, dehumidification or auto mode. Only available in Cooling or
Heating mode.
6. When the machine is in Sleeping function, the Fan Speed would turn to be
LOW speed.
Swing function
By pressing SWING button, the air vent will rise in 3 different angles: 60º68º75º
Every time when you turn on the machine, the air vent will rise to position 75º first, then
return to the pre-set position automatically. If you reset the SWING button, the air vent
will rise to position 75º first, too.
Dehumidification function
In dehumidification mode, the temperature cannot be adjusted, the ventilation will fix at
low speed.
Heating function
There are 2 different Heating characteristics developed – Heat Pump (reverse type) and
PTC heater. Only one function can be carried out in a machine.
- When using Heat Pump, the ambient warm air (usually spelled during the
summer season) is recycled and use to heat the area where it is required. The
Exhaust Pipe must be still fitted to allow the cold air to be removed in this
mode & used in the usual way. Under this system, the machine can run at
HIGH/MED./LOW speed.
- When using PTC heater function, the machine can only run at MED. Speed.
TiO2 / Ionizer function
1. This is only for the model with TiO2 or Ionizer function, i.e. model no. with T or I. T
stands for TiO2, I stands for Ionizer. * TiO2 is a kind of photochemical catalysis.
2. To start the TiO2 or Ionizer button, please press TiO2/Ionizer button. These 2
functions can clean the air, improve the air quality.
10
11
Self-diagnosis
This machine is equipped with self-diagnosis function. If something is wrong in the
machine, the LCD will show the word “E1” or “E2”. As this time, please call your service
centre.
NOTICE !
1. To prolong the compressor's life, after switch-off of the unit, please wait for 3
minutes (at least) before re-switch.
2. The cooling system will switch off if the ambient temperature is lower than the set
one. The ventilation, however, keeps working on the set level. If the ambient
temperature rises above the selected level, the cooling will return to work.
3. On the contrary, the heating will switch off if the ambient temperature is higher than
the set one (still, the ventilation keeps working on the set level). As the ambient
temperature drops below the selected level, the heating will return to work.
4. This machine is equipped with ANTI-FROST function. While using the heating
function during low temperature, sometimes the heating will stop for a while in order
to melt the frost. As this occurs, just wait for the heating returns to work.
All the above functions can also be performed
with the supplied remote control.
This remote control requires 2 pcs AAA batt
eries
to operate
FIG.13
12
.
DRAINAGE
During the process of cooling, some water will be extracted from the air into the unit. If
the reservoir is full, both of the compressor and motor will stop. The “water full” sign will
light on, also the machine will beep as reminder.
To make the cooling work again, please empty the water by one of the following ways:
1. Turn off the air conditioner and avoid
moving it when full.
2. Position a container (a water tray for
example) underneath the drain hole.
3.
Remove the drain knob & rubber plug
from the drain hole and allow the
water to drain out.
4. When the container is almost full,
replace the rubber plug in the drain
hole and empty the water tray.
5. Repeat until the unit is emptied.
6. Replace the rubber plug and tighten
the drain knob firmly.
7. Switch on the unit - the full water or
compressor operating indicator
should not be flashing.
FIG.14
If you wish to operate the unit without the need to empty the water tank, please:
Remove the drain knob and rubber
plug and retain for future use.
Connect the drain tube supplied to
the water outlet as shown and locate
the other end into a drain.
FIG.15
13
The drain tube may be
extended by adding an
extension tube and using a
suitable connector.
FIG.16
Please note
1.
The drain must be at or
below the outlet level.
2.
Flashing comp / ‘full water’
indicator will not function in
this mode of drainage.
3. If you want to extend the
water tube, you can connect
it with another tube (OD:
18mm)
FIG.17
Special caution for heating function !
While using the heating function,
please note:
1. Install the exhaust pipe well, in
order to exhaust the cool air to
outdoor. (Please refer to the
instruction manual for
installation method.)
2. Fix the drainage to be
continuous one (i.e. drain the
water by water tube).
3.
Working range for heating
function is 7 to 27
o
C (for cooling
function, it is 18 to 32
o
C). For
temperature outside this range,
the unit may not work properly.
FIG.18
14
.
MAINTENANCE
Always unplug the air conditioner from the mains before cleaning.
To maximize the efficiency of the air conditioner clean regularly.
Cleaning the housing
Use a soft, damp cloth to wipe the body clean.
Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or
other cleansing solutions. These all could possibly hurt the cabinet.
Cleaning the filter
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the
filters and then rinse thoroughly under running water (no hotter than 40
o
C).
Dry thoroughly before replacing.
Notice! Never operate the unit without the filters.
End of season storage
Drain any water in the unit before
completely operating the unit on
ventilation only mode for a few
hours, to thoroughly dry the inside.
Clean or change the filter
Unplug and store the power cord
as shown
Replace in the original carton or
cover for storage.
FIG.19
15
.
FAULT CHECK LIST
The air conditioner does not run
Is the air conditioner plugged in?
Is there a power failure?
Is the comp / ‘full water indicator flashing?
Is the room temperature below the set
temperature?
The machine seems to do little
Is there dire
ct sunshine ? (Please put down
the curtain.)
Are too many windows or doors open?
Are there too many people in the room?
Is there something in the room producing lots
of heat?
The machine seems to do nothing.
Is the filter dusty, contaminated?
Is the air intake or output blocked up?
Is the room temperature below your selected
temperature?
Too noisy
Is the machine positioned unevenly so as to
create vibration ?
Is the floor underneath the machine uneven?
The compressor doesn’t run.
Is so, it is possible the overheat protection of
the compressor is on. Just wait for the
temperature to drop.
Never try to repair or dismantle the unit yourself
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact the
retailer where the product was purchased. They can take this product for
environmental safe recycling.
14

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Suntec-Wellness-Advance-3.5-MM-Plus

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Suntec Wellness Advance 3.5 MM Plus bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Suntec Wellness Advance 3.5 MM Plus in de taal/talen: Engels als bijlage per email.

De handleiding is 0,6 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info