80-0078-00-MO-RevD 2018-08-02 SunTech CT50 User Manual | 16
• The software was developed in compliance with IEC 62304. The possibility of hazards arising from
software errors is minimized.
• This manual describes all features and options. Your monitor may not have all of them.
2.2 General Safety
Warning: This monitor is neither a therapeutic instrument nor a device that can be used at home.
1.Safety precautions for installation
• Connect the power cord to a properly grounded socket. Only connect device to A/C power sockets
designated for use by medical equipment.
• Avoid putting the monitor in a location where it easily shakes or wobbles.
• Enough space shall be left around the monitor to guarantee normal ventilation.
• Make sure the ambient temperature and humidity are stable and avoid the occurrence of condensation in
the operation process of the monitor.
Warning: To avoid explosion hazard, do not use the monitor in the presence of flammable anesthetics or other
flammable substance in combination with air, oxygen-enriched environments, or nitrous oxide.
2. Monitor conforms to the safety requirements of IEC 60601-1. This monitor is protected against defibrillation
effects.
3. Notes on symbols related to safety
Type CF applied part, defibrillation protected
The unit displaying this symbol contains an F-Type isolated (floating) applied part providing a high
degree of protection against shock, and is defibrillator-proof. The type CF applied parts provide a higher
degree of protection against electric shock than that provided by type BF applied parts.
Attention! Please refer to the documents accompanying this monitor, such as the instruction manual.
4. When a defibrillator is applied on a patient, the monitor may have some disruption in its display of waveforms.
Warning: When conducting defibrillation, do not allow the device to come into contact with the patient, the bed
or the monitor. Otherwise serious injury or death could result.
5. To guarantee the safe operation of the monitor, the monitor is provided with various replaceable parts, accessories
and consumables. Please use the products provided or designated by the manufacturer.
6. Safety and accuracy are assured only for the device and accessories provided or designated by the manufacturer.
If the monitor is connected to other undesignated electrical equipment or devices, safety hazards and/or excessive
leakage current may occur.
7. To guarantee the normal and safe operation of the monitor, a preventive check and maintenance should be
conducted of the monitor and its parts every 6-12 months (including performance and safety check) to verify that the
instrument can be operated safely, properly, and accurately.