1. General information
The chapter Operation” is intended for appliance users and
heating contractors.
The chapter “Installation” is intended for heating contractors.
Note
Read these instructions carefully before using the
appliance and retain them for future reference.
Pass on the instructions to a new user if required.
1.1 Safety instructions
1.1.1 Structure of safety instructions
!
KEYWORD Type of risk
Here, possible consequences are listed that may result
from failure to observe the safety instructions.
Steps to prevent the risk are listed.
1.1.2 Symbols, type of risk
 
!
Injury
Electrocution
Burns
(burns, scalding)
1.1.3 Keywords
 
DANGER Failure to observe this information will result in serious
injury or death.
WARNING Failure to observe this information may result in serious
injury or death.
CAUTION Failure to observe this information may result in non-
serious or minor injury.
OPERATION
1. General information �����������������������������������������2
1.1 Safety instructions ����������������������������������������������� 2
1.2 Other symbols in this documentation ����������������������� 3
1.3 Units of measurement ������������������������������������������ 3
2. Safety ����������������������������������������������������������3
2.1 Correct use �������������������������������������������������������� 3
2.2 Safety instructions ����������������������������������������������� 3
2.3 CE designation ��������������������������������������������������� 3
3. Appliance description ���������������������������������������4
4. Operation �����������������������������������������������������4
4.1 Temperature selector ������������������������������������������� 4
4.2 Draw-off capacities���������������������������������������������� 4
4.3 Thermostatic valve ���������������������������������������������� 4
4.4 Temperature limit/Anti-scalding protection ���������������� 4
5. Cleaning, care and maintenance ���������������������������4
6. Troubleshooting ����������������������������������������������4
INSTALLATION
7. Safety ����������������������������������������������������������5
7.1 General safety instructions ������������������������������������ 5
7.2 Instructions, standards and regulations �������������������� 5
7.3 Water installation ������������������������������������������������ 5
7.4 Risk of frost ������������������������������������������������������� 5
8. Appliance description ���������������������������������������6
8.1 Standard delivery ������������������������������������������������ 6
8.2 Installation �������������������������������������������������������� 6
8.3 Temperature limiting/anti-scalding protection ������������ 6
8.4 Installation versions ��������������������������������������������� 6
8.5 Accessories �������������������������������������������������������� 6
9. Installation ����������������������������������������������������7
9.1 Installation information ���������������������������������������� 7
10. Installation ����������������������������������������������������7
10.1 Installation location ��������������������������������������������� 7
10.2 Installation �������������������������������������������������������� 8
10.3 Installation versions �������������������������������������������� 10
11. Commissioning ��������������������������������������������� 13
12. Appliance handover ���������������������������������������� 13
13. Troubleshooting �������������������������������������������� 14
13.1 Display options LED diagnostic "traffic lights" ������������ 14
13.2 Fault table �������������������������������������������������������� 14
14. Specification ������������������������������������������������ 15
14.1 Dimensioned drawing ����������������������������������������� 15
14.2 Wiring diagram �������������������������������������������������15
14.3 Mixed water volume / outlet volume ����������������������� 15
14.4 Application areas ����������������������������������������������� 15
14.5 Pressure drop ��������������������������������������������������� 15
14.6 Fault conditions ������������������������������������������������� 15
14.7 Country-specific approvals and certifications ������������� 15
14.8 Specification ����������������������������������������������������� 16
WARRANTY | ENVIRONMENT AND RECYCLING


ENGLISH
 
1.2 Other symbols in this documentation
Note
General information is identified by the symbol shown
on the left.
Read these texts carefully.
 
!
Material damage
(appliance, consequential and environmental damage)
Appliance disposal
This symbol indicates that you have to do something. The
action you need to take is described step by step.
1.3 Units of measurement
Note
All measurements are given in mm unless stated
otherwise.
2. Safety
2.1 Correct use
The appliance is a pressure appliance for heating domestic hot
water.
Any other use beyond that described shall be deemed inappropriate.
Observation of these instructions is also part of the correct use of
the appliance. Any changes or conversions to the appliance void
any warranty.
2.2 Safety instructions
Observe the following safety information and instructions.
Only heating contractors should install and commission the
appliance.
The contractor is responsible for adherence to all currently
applicable regulations during installation and commissioning.
Operate this appliance only if it is fully installed and all safety
equipment is fitted.
CAUTION Burns
There is a risk of scalding at outlet temperatures in excess
of 43°C.
CAUTION Burns
If operating with preheated water, e.g. from a solar
thermal system, the DHW temperature may vary from
the selected set temperature.
!
WARNING Injury
Where children or persons with limited physical, sensory
or mental capabilities are to be allowed to control this
appliance, ensure that this will only happen under
supervision or after appropriate instructions by a person
responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
!
Material damage
Do not operate the appliance following an interruption to
the water supply. This can destroy the bare wire heating
system. Run water for at least a minute before restarting
the appliance (see chapter "Troubleshooting").
2.3 CE designation
The CE designation shows that the appliance meets all the essential
requirements:
- Low Voltage Directive (Council Directive 2006/95/EC).
- Electromagnetic Compatibility Directive
The maximum permissible mains impedance is indicated in
chapter “Specification/ Data table”.


 
3. Appliance description
This electronically controlled instantaneous water heater with
automatic output matching keeps the outlet temperature constant.
This occurs regardless of the inlet temperature up to the output
limit. The DHW outlet temperature can be freely selected.
The bare wire heating system is suitable for hard and soft water
areas; it has low susceptibility to scale build-up. The heating
system ensures quick and efficient DHW availability.
4. Operation
4.1 Temperature selector
DHB-E ... SLi
30
60
45
35
40
50
55
2602�02�1381
DHB-E ... A
30
50
40
35
45
2602�02�1382
Should the outlet temperature fail to reach the required level with
the draw-off valve fully open and the temperature selector set to
maximum, then more water flows through the appliance than can
be heated by the heating element.
Reduce the flow rate with the draw-off valve.
4.2 Draw-off capacities
Subject to season, varying maximum mixed water or draw-off
capacities result from different cold water temperatures. Further
information can be found in the chapter "Specification".
4.3 Thermostatic valve
We recommend adjusting the appliance to the maximum
temperature setting.
4.4 Temperature limit/Anti-scalding protection
The maximum outlet temperature for the appliance can be limited
to 43°C. Refer in this case to your local heating contractor.
5. Cleaning, care and maintenance
Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
Maintenance work, such as checking the electrical safety, must
only be carried out by a heating contractor.
6. Troubleshooting
!
Material damage
Following an interruption of the water supply,
recommission the appliance by carrying out the following
steps, in order to prevent the destruction of the bare wire
heating system.
Disconnect the appliance from the power supply by
removing the fuses/tripping the MCBs.
Open the tap until the appliance and its upstream
cold water inlet line are free of air.
Switch the mains power back ON again.
  
The appliance will not
start in spite of a fully
open DHW valve.
There is no voltage.
Check the fuse/MCB
in your fuse box/
distribution panel.
Starting volume is not
achieved. The perlator in
the tap or shower head is
scaled up or dirty.
Clean and/or descale the
perlator or the shower
head.
The heating system is
faulty.
Contact your heating
contractor.
The air sensor detects air
in the water and briefly
switches the heater off.
The appliance restarts
automatically after one
minute.
Required temperature
>45 °C is not achieved.
Cold water inlet
temperature is > 45 °C.
Reduce the cold water
inlet temperature.
If you cannot remedy the fault, contact your heating contractor.
For better and faster help, provide him with the serial number
from the type plate (no. 000000-0000-000000):
DHB-E ...
2602�02�0818
ENGLISH
 



7. Safety
7.1 General safety instructions
All required steps to complete commissioning must be carried
out by a heating contractor. During this process, these installation
instructions must be observed.
We guarantee trouble-free function and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
7.2 Instructions, standards and regulations
!
Material damage
Observe the type plate. The stated voltage must match
the mains voltage.
WARNING Risk of electrocution
All electrical connection and installation work must
be conducted in accordance with VDE regulations
(DINVDE0100) [or local regulations], the rules of your
local power supply utility and relevant national and local
regulations.
WARNING Risk of electrocution
Connection to the power supply is only possible as
a xed connection. The appliance must be able to be
separated from the mains power supply by an isolator
that disconnects all poles with at least 3 mm contact
separation.
Note
Observe all national and local instructions and regulations
relating to water connection.
- The protection IP 25 (hoseproof) can only be ensured with a
correctly fitted cable grommet.
- The specific electrical resistant of the water used must not
fall below that stated on the type plate. In a linked water
network, observe the lowest electrical water resistance
(see chapter "Application areas"). Your water supply utility
will advise you of the specific electrical water resistance or
conductivity.
7.3 Water installation
7.3.1 Cold water line
Permissible materials: Galvanised steel pipe, stainless steel pipe,
copper pipe or plastic pipe.
7.3.2 DHW line
Permissible materials: Stainless steel pipe, copper pipe or plastic
pipe.
!
Material damage
If plastic pipework is used, observe the most extreme
operating and fault conditions that can occur in the
appliance.
Note
Observe the plastic pipe manufacturer's instructions.
- A safety valve in the hot water pipe is not permissible.
- Never operate with valves intended for open vented
appliances.
7.4 Risk of frost
The installation of the appliance must be carried out in a room
free from the risk of frost.
Store the dismantled appliance in a room free from the risk
of frost, as water residues remaining inside the appliance can
freeze and cause damage.
 


8. Appliance description
The bare wire heating system is suitable for hard and soft water
areas. The heater has low susceptibility to scale build-up.
The appliance is suitable for heating cold water or for reheating
preheated water. For temperatures, see chapter "Specification /
Data table".
The max. inlet temperature for reheating must not be exceeded.
There will be no reheating, if the inlet temperatures exceed this
maximum value.
Observe the "Max. inlet temperature". The appliance can be
damaged at higher temperatures. If a "central thermostat" is
installed (see chapter "Installation / Accessories"), you can limit
the "Max. inlet temperature".
The outlet temperature can be infinitely adjusted. The electronic
control unit enables automatic matching of the electrical output
corresponding to the selected temperature subject to the actual
throughput.
8.1 Standard delivery
- Mounting bracket
- Installation template
- Twin nipple
- Cross-piece
- Tee
- Flat packing
- Sieve
- Flow limiter
- Plastic profile washer
- Plastic cap
- Flexible plastic couplings
- Cap and back panel guides
8.2 Installation
The following conditions have been prepared for the appliance
at the factory:
- Power supply from "below", installation on unfinished walls
- Water connection, installation on unfinished walls
The appliance must be fitted vertically, over or undersink, to a
solid wall.
8.3 Temperature limiting/anti-scalding protection
The maximum temperature can be limited to 43°C via the user
interface on the appliance cap. The following steps are necessary
for this procedure:
Remove the appliance cap.
Remove the electronic PCB from the user interface on the
appliance cap. Be careful of the snap-on hooks.
Move the plug from left to right (position "43 °C").
Refit the user interface, ensuring the snap-on hooks click into
place. Observe the positions of the pushbutton and shaft.
CAUTION Burns
If operating with preheated water, the set temperature
limit and anti-scalding protection may be ineffective.
In this case, restrict the temperature at the
upstream central thermostatic valve; see chapter
Accessories”.
2602�02�0833
8.4 Installation versions
The following installation versions are possible/permissible:
- Power supply for unfinished walls - from above
- Power supply for finished walls
- Water installation for finished walls
- Installation with repositioned appliance cap
- Installation for offset tiles
- Installation of a load shedding relay
8.5 Accessories
Taps
- WKMD – twin-lever pressure-tested kitchen tap
- WBMD – twin-lever pressure-tested bath tap
Plug G½A
These plugs are required if you use twin-lever pressure-tested
taps for finished walls other than the ones recommended by us.
Installation sets for installation on finished walls
- Solder fitting – copper pipe for solder connection Ø12 mm.
- Compression fitting – copper pipe.
- Compression fitting – plastic pipe
(suitable for Viega: Sanfix-Plus or Sanfix-Fosta).
Universal mounting frame
- Mounting frame with electrical wiring.
Pipe set for undersink appliances
The set for undersink installation is required if you want to have
the water connections (G⅜A) above the appliance.
ENGLISH
 


Pipe set, offset installation
This pipe set with pipe bends is required if you want to have the
appliance vertically offset against the water connection by approx.
90 mm downwards.
Pipe set for replacing a gas water heater
This pipe set is required if the installation has existing gas water
heater connections (cold water connection on the left and DHW
connection on the right).
DHB replacement pipe set
2 water couplings. These allow the appliance to be connected to
the available water plug-in connections of a DHB.
Load shedding relay LR 1-A
The load shedding relay for installation in the electric distribution
board enables priority control of the instantaneous water heater
when electric storage heaters are being operated simultaneously,
for example.
ZTA 3/4 – Central thermostatic valve
Thermostatic valve for centralised premixing, e.g. an instantaneous
water heater in conjunction with a solar thermal system.
9. Installation
9.1 Installation information
9.1.1 Flow pressure
If the ow rate required for the appliance to switch on is not
achieved even with the tap fully open, remove the flow limiter.
Replace it with the plastic profile washer supplied. If required the
pressure in the water installation can also be raised.
Note
For the thermostatic valve to function correctly, the flow
limiter for this valve must not be replaced with the plastic
profile washer.
2
1
2602�02�0820
1 Flow limiter
2 Plastic profile washer
9.1.2 Flexible water connection lines
If the appliance is connected with exible water connection lines,
ensure that the bayonet fittings of the pipe bends do not become
twisted inside the appliance.
9.1.3 Appliance with changeover connected load
The appliance DHB-E 18/21/24 SLi is set to 21kW when delivered.
If the appliance is installed with a different output, take the
following steps:
Re-plug the coding card according to the selected output; for
selectable output and fuse protection of the appliance see
"Specification“.
Mark the selected output on the type plate using a
permanent marker.
Install the flow limiter with a rating corresponding to that of
the appliance. The colour of the flow limiter is given in the
table "Specification".
2602�02�0822
10. Installation
10.1 Installation location
The appliance is exclusively designed for installation on a solid
wall. Ensure that the wall has a sufficient load-bearing capacity.
Always install the appliance vertically (over or undersink) in a
room free from the risk of frost.
10.1.1 Undersink
1
2
2602�02�0807
1 Cold water inlet
2 DHW outlet
 


10.1.2 Oversink
2 1
2602�02�0806
1 Cold water inlet
2 DHW outlet
10.2 Installation
10.2.1 Opening the appliance
2602�02�0808
10.2.2 Removing the back panel
2602�02�1101
Press the two locking hooks on the r.h. and l.h. side and
remove the lower part towards the front.
10.2.3 Fitting the mounting bracket
Mark out the holes for drilling using the installation template.
If the appliance is to be installed with water connections
for finished walls, the fixing hole in the lower part of the
template must also be marked out.
Drill the holes and secure the mounting bracket with
twoscrews and two rawl plugs. The screws and rawl plugs
are not part of the standard delivery.
2602�02�0810
10.2.4 Fitting the power cable
160
30
2602�02�0824
Prepare the power cable.
Use the plastic cap as an installation aid.
10.2.5 Inserting the twin nipples
2602�02�0798
10.2.6 Preparing the water connection
Secure the tee and cross-piece to the twin nipples with flat
packing.
Thoroughly flush the cold water supply line.
Note
Never use the three-way shut-off valve to reduce the flow
rate; it is only designed to shut off a circuit.
1 2
2602�02�0799
1 Tee
2 Cross-piece
ENGLISH
 


10.2.7 Fitting the sieve
Fit the sieve provided in the cold water inlet of the appliance.
Note
The sieve must always be fitted for the function of the
appliance to be guaranteed. If an appliance is being
replaced during installation, ensure that a sieve is
available.
2602�02�0856
10.2.8 Installing the DMB flow limiter
Position the flow limiter provided in the cold water inlet of
the appliance.
A second flow limiter is provided with the DHB-E 18/21/24 SLi.
Install the ow limiter with an output corresponding to that of
the appliance.
Flow limiter, see "flow rate limit" in chapter "Specification":
4.0 l/min = pink
7.5 l/min = blue
8.5 l/min = green
2602�02�0857
10.2.9 Mounting the appliance
The cable grommet pointing towards the wall may hinder the
mounting of the appliance close to the wall. To prevent such
problems, it is advisable to briefly press the cable grommet from
behind into the back panel, to reduce the stiffness or the grommet.
Remove the fixing toggle from the upper part of the back
panel (diagram "Mounting the appliance").
Route the power cable from behind through the cable
grommet until it rests against the cable sheath. Align the
power cable. If the cross-section of the power cable is
greater than 6mm, enlarge the hole in the cable grommet
(see also "Power supply for larger cross-sections").
Push the appliance over the stud of the mounting bracket, so
that it breaks through the soft seal. If necessary pierce the
soft seal with a screwdriver.
Put the fixing toggle onto the stud of the mounting bracket
that penetrates the back panel.
Press the back panel firmly into place and lock the fixing
toggle by turning it through 90°.
2602�02�0811
10.2.10 Finalising the water connection
2602�02�0858
10.2.11 Connecting the power supply
Connect the power cable to the mains terminal (see chapter
"Wiring diagram").
WARNING Risk of electrocution
Ensure that the appliance is connected to earth.
2602�02�1122
 


10.2.12 Fitting the lower back panel
2602�02�1102�
10.2.13 Completing the installation process
Align the mounted appliance by loosening the fixing
toggle, aligning the power supply and back panel, and
then retightening the fixing toggle. If the back panel of the
appliance is not flush against the wall, the appliance can be
fixed with a screw in the lower part.
10.3 Installation versions
10.3.1 Power supply from above for unfinished walls
The following diagram shows the dimensions for the power supply
from above.
2602�02�0802
To connect the power supply, take the following steps:
Open out the cable grommet to match the cross-section of
the power cable.
Push down and remove the locking hook that secures the
mains terminal.
Move the mains terminal in the appliance from the bottom to
the top and click into place.
2602�02�1123
10.3.2 Power supply for finished walls
The appliance can also be connected if the power supply has been
routed over finished walls. This applies to the connection from
below and above. Take the following steps:
Cut or break knock-outs in the back panel and appliance
cap. Possible knock-out points can be seen in the diagram
"Dimensions for power supply".
Note
If the appliance has been connected with a power supply
on finished walls, the type of protection on the type plate
must be changed from IP 25 to IP 24. Use a permanent
marker for that.
Cross out "IP 25" and mark the box "IP 24".
10.3.3 Power supply for large cross-sections
1.
3.
4.
2.
2602�02�1124
If cables with a large cross-section are used, the cable grommet
can be tted after the appliance has been installed. Take the
following steps:
Before installing the appliance, use a screwdriver to push the
cable grommet out.
ENGLISH
 


Push the appliance over the stud of the mounting bracket, so
that it breaks through the soft seal.
Push the fixing toggle onto the stud of the mounting bracket
that penetrates the back panel.
Press the back panel firmly into place and lock the fixing
toggle by turning it through 90°.
Push the cable grommet over the power cable. For this, use
the installation aid. For a power cable of 10 or 16 mm², the
hole in the cable grommet must be enlarged. Click the cable
grommet into place in the back panel.
10.3.4 Connecting a load shedding relay
Install the load shedding relay in conjunction with other electric
appliances, e.g. electric storage heaters. The relay responds when
the instantaneous water heater starts. The load shedding relay is
available from Stiebel Eltron as a special accessory.
Note
Connect the phase that switches the load shedding relay
to the indicated terminal of the mains terminal in the
appliance.
2
1
8502�02�0003
1 Control cable to the contactor of the second appliance (e.g.
electric storage heater).
2 Control contact, opens when switching the instantaneous
water heater on.
10.3.5 Water installation for finished walls
Suitable pressure taps WKMD or WBMD for installation on finished
walls are available as special accessories.
Fit the water plugs with gaskets to seal the connection
(below the plaster). With Stiebel Eltron pressure taps, plugs
and gaskets are part of the standard delivery. For third party
pressure taps, plugs and gaskets can be ordered as special
accessories.
Install the tap.
Push the lower part of the back panel under the connection
pipes of the pressure tap and click it into place in the back
panel.
Secure the connection pipes to the appliance.
2602�02�0528
WKMD
WBMD
10.3.6 Water installation for finished walls with solder/
compression fitting
With the special accessories "solder fitting" or "compression fitting"
(see "Accessories"), copper or plastic pipes can be connected in
installations for finished walls.
With special accessory "solder tting", a threaded connection with
on-site 12 mm copper pipes is possible. For this the following
steps are required:
Push the union nuts over the connection pipes.
Solder the inserts to the copper pipes.
Push the lower part of the back panel under the connection
pipes and click it into place in the back panel.
Secure the connection pipes to the appliance.
Note
Observe the valve manufacturer's installation instructions.
10.3.7 Water installation for finished walls, fitting the
appliance cap
The following steps are necessary to complete the appliance cap
installation.
Cleanly break out the knock-out in the appliance cap. If
necessary, use a file.
Break the tabs out of the cap guides.
Note
The appliance can be sealed by fitting the cap guides with
tabs if the tap pipes are slightly offset. The back panel
guides are not required in this case.
Click the cap guides provided into place in the knock-outs.
Position the back panel guides on the pipes and push them
together. Then push the guides until they meet the back
panel.
Secure the back panel at the bottom with a screw. This is
also relevant if flexible water supply systems are used.
 


2602�02�0821
3
1
2
1 Knock-out
2 Cap guides
3 Back panel guides
10.3.8 Installing lower part of back panel
If using threaded connections for finished walls, the lower part of
the back panel can also be installed after fitting the taps/valves.
To do this, carry out the following steps:
Cut open the lower part of the back panel.
Fit the lower part of the back panel by bending it out at the
sides and guiding it over the pipes.
Insert the connection pieces from behind into the lower part
of the back panel.
Click the lower part of the back panel into place.
Secure the lower part of the back panel with a screw.
2602�02�1080
21
3
1 Lower part of back panel
2 Connection piece from the pack
3 Screw
10.3.9 Installation in case of appliance replacement
An existing mounting bracket can be used when replacing Stiebel
Eltron appliances (except "DHF"). For this, open a suitable knock-
out in the back panel for the stud of the existing mounting bracket.
If the appliance is being installed in place of a DHF, move the
stud on the mounting bracket as shown in the diagram "Mounting
bracket for DHF appliance replacement". The stud cuts its own
groove. Then turn the mounting bracket through 180° to be
mounted on the wall. The logo "DHF" is then turned towards the
reader.
If replacing a third party appliance, suitable holes for rawl plugs
can be used.
2602�02�0815
10.3.10 Undersink installation with turned appliance cap
The appliance cap can be positioned on the back panel turned
through 180°. This particularly advantageous for undersink
installation. For this take the following steps:
Remove the user interface from the appliance cap by
pressing the locking hooks.
Turn the appliance cap and click the user interface into place,
ensuring that all locking hooks click into place. To install the
user interface more easily, press against the inner side of the
appliance cap (in the shaded area, see diagram "Appliance
cap for undersink installation").
!
Material damage
Never install a user interface with a faulty locking
hook. Otherwise the safety of the appliance cannot be
guaranteed.
Plug the set value transducer cable into the "set temperature"
PCB; see "Commissioning".
Hook the appliance cap in at the bottom and pivot it up onto
the back panel. Ensure the all-round seal of the back panel
sits tightly by pushing the cap gently forwards and back.
Close the appliance with the screw in the cap.
2602�02�0817
ENGLISH
 


10.3.11 Installation for offset tiles
This appliance can be installed where tiles are offset. See
diagram for maximum tile offset and minimum contact area of
the appliance. Adjust the wall clearance and lock the back panel
with the fixing toggle by turning it clockwise through 90°.
110
20
2602�02�0829
11. Commissioning
WARNING Risk of electrocution
Commissioning must only be carried out by an authorised
contractor in accordance with safety regulations.
30
60
45
35
40
50
55
°C
el ec tro ni c
30
60
45
35
40
50
55
°C
el ec tro ni c
..
2..
2602�02�1183
Open and close all connected draw-off valves several times,
until all air has been vented from the pipework and the
appliance.
Activate the safety pressure switch at flow pressure by
pressing the reset button. The appliance is supplied with the
safety pressure limiter deactivated.
Push the temperature selector plug into the "set
temperature" PCB.
Fit the appliance cap and secure with a screw.
Switch the mains power ON.
Calibrate the temperature by turning the temperature
selector as far as possible clockwise and then anti-clockwise.
Check the appliance function.
Remove the protective foil from the user interface.
12. Appliance handover
Explain the appliance function to the user and familiarise
him/her with its operation.
Make the user aware of potential dangers, especially the risk
of scalding.
Hand over these instructions to the user for safe-keeping.
 


13. Troubleshooting
WARNING Risk of electrocution
To test the appliance, it must be supplied with power.
13.1 Display options LED diagnostic "traffic lights"

red illuminates in case of faults
yellow illuminates when the appliance is heating water
green flashing: The appliance is supplied with power
13.2 Fault table


 
The appliance does not start. The shower head / perlators are scaled up. Descale or if necessary replace the shower head /
perlators.
Inadequate flow rate. The sieve in the appliance is dirty. Clean the sieve.
Set temperature is not achieved. One phase down. Check the MCB/fuse in your fuse box.
Heating does not switch on. The air sensor detects the presence of air in the water
and briefly switches the heater off.
The appliance restarts after one minute.
No hot water and no "traffic light" display. The MCB/fuse has responded/blown. Check the MCB/fuse in your fuse box.
Safety pressure limiter AP 3 has tripped. Remove the cause of the fault (e.g. faulty pressure
washer).
Protect the system against overheating by opening
a draw-off valve downstream of the appliance for
1 minute. This depressurises and cools down the
heating system.
Activate the safety pressure switch at flow pressure
by pressing the reset button.
The PCB is faulty. Check the PCB and replace if necessary.
Traffic light display: Green flashing
No hot water at flow rate of
>3l/min.
Flow sensor (DFE) is not plugged in.
Plug the flow sensor plug back in.
Flow sensor DFE is faulty. Check the flow sensor and replace if necessary.
The set temperature is not achieved.
The set value transducer or connecting cable is faulty or
the connecting cable is not attached.
Attach the connecting cable; replace the set value
transducer if required.
Temperature limiting is activated. Disable temperature limiting.
Traffic light display: Yellow constantly ON;
green flashing
No hot water at flow rate of >3l/min.
The high limit safety cut-out has responded or its lead
is broken.
Check the high limit safety cut-out and replace if
necessary.
The heating system is faulty. Measure the resistance of the heating system and
replace if necessary.
The PCB is faulty. Check the PCB and replace if necessary.
Traffic light display: yellow constantly ON;
green flashing
The outlet sensor is faulty. Check the connection and replace the outlet sensor
if necessary.
Set temperature is not achieved. Appliance operates at its output limit. Reduce the flow rate or install the flow limiter.
Traffic light display: red constantly ON; green
flashing
The outlet sensor is faulty. Check the connection and replace the outlet sensor
if necessary.
No hot water The cold water sensor is faulty. Check the PCB and replace if necessary.
Required temperature > 45 °C is not achieved. The cold water inlet temperature exceeds 45 °C. Reduce the cold water inlet temperature to the
appliance.
ENGLISH
 


14. Specification
14.1 Dimensioned drawing
478
100
414
44
105≤ 20225
140
30
35
35
114
368
338
47
b02
b01
c01c06
D0000017973
b01 Entry electrical cables
b02 Entry electrical cables 1
c01 Cold water inlet male thread G 1/2 A
c06 DHW outlet male thread G 1/2 A
14.2 Wiring diagram
3/PE~380 - 415V
8502�02�0005�
1 Heater
2 High limit safety cut-out
3 Safety pressure limiter
14.3 Mixed water volume / outlet volume
Available temperature approx. 38 °C in the shower, for hand
washing, filling the bath etc.

Appliance kW 11 18 21 24 27
Cold water inlet
6 °C l/min 5.0 8.0 9.4 10.7 12.1
temperature
10 °C l/min 5.7 9.2 10.7 12.3 13.8
14 °C l/min 6.6 10.7 12.5 14.5 16.1
Outlet temperature approx. 60 °C for the kitchen sink and when
using thermostatic valves.

Appliance kW 11 18 21 24 27
Cold water inlet
6 °C l/min 2.9 4.8 5.6 6.4 7.2
temperature
10 °C l/min 3.2 5.2 6.0 6.9 7.7
14 °C l/min 3.4 5.6 6.5 7.5 8.4
The values in the table are relative to a rated voltage of 400 V. The
outlet volume is subject to the available supply pressure and the
available mains voltage.
14.4 Application areas
Specific electrical resistance and specific electrical conductivity

Standard value
at 15 °C
at 20 °C
at 25 °C
Resistance Ω cm ≥ 900 ≥ 1000 ≥ 800 ≥ 890 ≥ 735 ≥ 815
Conductivity mS/m ≤ 111 ≤ 100 ≤ 125 ≤ 112 ≤ 136 ≤ 123
Conductivity µs/cm ≤ 1110 ≤ 1000 ≤ 1250 ≤ 1120 ≤ 1360 ≤ 1230

Standard value
at 15 °C
at 20 °C
at 25°C
Resistance Ω cm ≥ 1200 ≥ 1300 ≥ 1070 ≥ 1175 ≥ 985 ≥ 1072
Conductivity mS/m ≤ 83 ≤ 77 ≤ 94 ≤ 85 ≤ 101 ≤ 93
Conductivity µs/cm ≤ 830 ≤ 770 ≤ 940 ≤ 850 ≤ 1010 ≤ 930
14.5 Pressure drop
14.5.1 Taps/valves

Mono-lever mixer tap, approx. MPa 0.04 - 0.08
Thermostatic valve, approx. MPa 0.03 - 0.05
Hand shower, approx. MPa 0.03 - 0.15
14.5.2 Sizing the pipework
When calculating the size of the pipework, a pressure drop for the
appliance of 0.1 MPa is recommended.
14.6 Fault conditions
In case of faults, loads up to a maximum of 95 °C at a pressure of
1.2 MPa can occur temporarily in the installation.
14.7 Country-specific approvals and certifications
Test symbols can be seen on the type plate.
 


14.7.1 Notice for Australia / New Zealand:
The installation shall comply with AS/NZS 3500.4.
14.8 Specification
     
232013 232014 232360 232015 232016 232017
Electrical details
Rated voltage 1 V 380 380 380 380 380 380
Rated output 1 kW 10.1 12.2 16.2 16.2/19/21.7 24.4
Rated current 1 A 15.4 18.5 24.7 27.6/29.5/33.3 37.1
Fuse 1 A 16 20 25 32/32/35 40
Rated voltage 2 V 400 400 400 400 400 400
Rated output 2 kW 11 13.5 18 18/21/24 27
Rated current 2 A 16 19.5 26 29/31/35 39
Fuse 2 A 16 20 25 32/32/35 40
Rated voltage 3 V 415 415 415 415 415 415
Rated output 3 kW 14.5
Rated current 3 A 20.2
Fuse 3 A 20
Phases 3/PE 3/PE 3/PE 3/PE 3/PE 3/PE
Frequency Hz 50/60 50/60 50 50/60 50/60 50/-
Max. mains impedance Zmax to DIN EN
61000-3-11
Ohm 0.45 0.43 0.45 0.33 0.3
Specific resistance (≤25 °C) Ohm cm 900 900 1000 900 900 900
Specific resistance (>25 °C) Ohm cm 1200 1200 1300 1200 1200 1200
Connections
Water connection G 1/2 A G 1/2 A G 1/2 A G 1/2 A G 1/2 A G 1/2 A
Application limits
Max. permissible pressure MPa 1 1 1 1 1 1
Max. inlet temperature for reheating °C 45 45 45 45 45 45
Values
Max. permissible inlet temperature °C 60 60 60 60 60 60
ON l/min >3.0 >3.0 >3.0 >3.0 >3.0 >3.0
Flow rate for pressure drop l/min 3.1 3.9 3.9 5.2 5.2/6.0/6.9 7.7
Pressure drop at flow rate
MPa
0.07 (0.02
without flow
rate limit)
0.11 (0.03
without flow
rate limit)
0.11 (0.03
without flow
rate limit)
0.08 (0.06 without
flow rate limit)
0.08/0.10/0.13
(0.06/0.08/0.10 without
flow rate limit)
0.16 (0.12
without flow
rate limit)
Flow rate limit at l/min 4.0 4.0 4.0 7.5 7.5/7.5/8.5 8.5
DHW delivery l/min 5.6 6.9 6.9 9.2 9.2/10.7/12.3 13.8
Delta T if presented K 28 28 28 28 28 28
Hydraulic data
Rated capacity l 0.4 0.4 0.4 0.4 0.4 0.4
Versions
Connected load options - - - - X -
Temperature adjustment °C 30 - 60 30 - 60 30-50 30 - 60 30 - 60 30 - 60
Protection class 1 1 1 1 1 1
Insulation block Plastic Plastic Plastic Plastic Plastic Plastic
Heating system Bare wire Bare wire Bare wire Bare wire Bare wire Bare wire
Cap and back panel Plastic Plastic Plastic Plastic Plastic Plastic
Colour white white white white white white
IP-Rating IP25 IP25 IP25 IP25 IP25
Dimensions
Height mm 478 478 478 478 478 478
Width mm 225 225 225 225 225 225
Depth mm 105 105 105 105 105 105
Weights
Weight kg 3.6 3.6 3.6 3.6 3.6 3.6

ENGLISH
 
Warranty
The warranty conditions of our German companies do not
apply to appliances acquired outside of Germany. In countries
where our subsidiaries sell our products, it is increasingly the
case that warranties can only be issued by those subsidiaries.
Such warranties are only granted if the subsidiary has issued
its own terms of warranty. No other warranty will be granted.
We shall not provide any warranty for appliances acquired in
countries where we have no subsidiary to sell our products.
This will not aect warranties issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use,
dispose of the various materials in accordance with national
regulations.

 

ENGLISH
 

Deutschland
STIEBEL ELTRON GmbH & Co. KG
Dr.-Stiebel-Straße | 37603 Holzminden
Tel. 05531 702-0 | Fax 05531 702-480
info@stiebel-eltron.de
www.stiebel-eltron.de
Verkauf Tel. 05531 702-110 | Fax 05531 702-95108 | info-center@stiebel-eltron.de
Kundendienst Tel. 05531 702-90015 | Fax 05531 702-95890 | kundendienst@stiebel-eltron.de
Ersatzteilverkauf Tel. 05531 702-90050 | Fax 05531 702-95335 | ersatzteile@stiebel-eltron.de
Irrtum und technische Änderungen vorbehalten! | Subject to errors and technical changes! | Sous réserve
d‘erreurs et de modifications techniques! | Onder voorbehoud van vergissingen en technische wijzigingen! |
Salvo error o modificación técnica! | Excepto erro ou alteração técnica | Zastrzeżone zmiany techniczne i
ewentualne błędy | Omyly a technické změny jsou vyhrazeny! | A muszaki változtatások és tévedések jogát
fenntartjuk! |
Отсутствие ошибок не гарантируется. Возможны технические изменения.
| Chyby a
technické zmeny sú vyhradené! Stand 8753
Australia
STIEBEL ELTRON Australia Pty. Ltd.
4/8 Rocklea Drive | 3207 Port Melbourne
Tel. 03 9645 1833 | Fax 03 9421 2302
info@stiebel.com.au
www.stiebel.com.au
Austria
STIEBEL ELTRON Ges.m.b.H.
Eferdinger Str. 73 | 4600 Wels
Tel. 07242 47367-0 | Fax 07242 47367-42
info@stiebel-eltron.at
www.stiebel-eltron.at
Belgium
STIEBEL ELTRON bvba/sprl
't Hofveld 6 - D1 | 1702 Groot-Bijgaarden
Tel. 02 42322-22 | Fax 02 42322-12
info@stiebel-eltron.be
www.stiebel-eltron.be
Czech Republic
STIEBEL ELTRON spol. s r.o.
K Hájům 946 | 155 00 Praha 5 - Stodůlky
Tel. 251116-111 | Fax 235512-122
info@stiebel-eltron.cz
www.stiebel-eltron.cz
Denmark
Pettinaroli A/S
Mandal Allé 21 | 5500 Middelfart
Tel. 06341 666-6 | Fax 06341 666-0
info@stiebel-eltron.dk
www.stiebel-eltron.dk
Finland
Insinööritoimisto Olli Andersson Oy
Kapinakuja 1 | 04600 Mäntsälä
Tel. 020 720-9988 | Fax 020 720-9989
info@stiebel-eltron.fi
www.stiebel-eltron.fi
France
STIEBEL ELTRON SAS
7-9, rue des Selliers
B.P 85107 | 57073 Metz-Cédex 3
Tel. 0387 7438-88 | Fax 0387 7468-26
info@stiebel-eltron.fr
www.stiebel-eltron.fr
Hungary
STIEBEL ELTRON Kft.
Gyár u. 2 | 2040 Budaörs
Tel. 01 250-6055 | Fax 01 368-8097
info@stiebel-eltron.hu
www.stiebel-eltron.hu
Japan
NIHON STIEBEL Co. Ltd.
Kowa Kawasaki Nishiguchi Building 8F
66-2 Horikawa-Cho
Saiwai-Ku | 212-0013 Kawasaki
Tel. 044 540-3200 | Fax 044 540-3210
info@nihonstiebel.co.jp
www.nihonstiebel.co.jp
Netherlands
STIEBEL ELTRON Nederland B.V.
Daviottenweg 36
5222 BH 's-Hertogenbosch
Tel. 073 623-0000 | Fax 073 623-1141
stiebel@stiebel-eltron.nl
www.stiebel-eltron.nl
Poland
STIEBEL ELTRON Polska Sp. z o.o.
ul. Działkowa 2 | 02-234 Warszawa
Tel. 022 60920-30 | Fax 022 60920-29
stiebel@stiebel-eltron.pl
www.stiebel-eltron.pl
Russia
STIEBEL ELTRON LLC RUSSIA
Urzhumskaya street 4,
building 2 | 129343 Moscow
Tel. 0495 7753889 | Fax 0495 7753887
info@stiebel-eltron.ru
www.stiebel-eltron.ru
Slovakia
TATRAMAT - ohrievače vody, s.r.o.
Hlavná 1 | 058 01 Poprad
Tel. 052 7127-125 | Fax 052 7127-148
info@stiebel-eltron.sk
www.stiebel-eltron.sk
Switzerland
STIEBEL ELTRON AG
Netzibodenstr. 23 c | 4133 Pratteln
Tel. 061 81693-33 | Fax 061 81693-44
info@stiebel-eltron.ch
www.stiebel-eltron.ch
Thailand
STIEBEL ELTRON Asia Ltd.
469 Moo 2 Tambol Klong-Jik
Amphur Bangpa-In | 13160 Ayutthaya
Tel. 035 220088 | Fax 035 221188
info@stiebeleltronasia.com
www.stiebeleltronasia.com
United Kingdom and Ireland
STIEBEL ELTRON UK Ltd.
Unit 12 Stadium Court
Stadium Road | CH62 3RP Bromborough
Tel. 0151 346-2300 | Fax 0151 334-2913
info@stiebel-eltron.co.uk
www.stiebel-eltron.co.uk
United States of America
STIEBEL ELTRON, Inc.
17 West Street | 01088 West Hatfield MA
Tel. 0413 247-3380 | Fax 0413 247-3369
info@stiebel-eltron-usa.com
www.stiebel-eltron-usa.com
A 296851-36842-8753
B 296850-36842-8753 M
4<AMHCMN=jgifbc>
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Stiebel Eltron DHB-E 13 A bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Stiebel Eltron DHB-E 13 A in de taal/talen: Engels als bijlage per email.

De handleiding is 7 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info