- 8 - - 9 -
Technische Daten
RS PRO LED S1 RS PRO LED S1 IP 65
Abmessungen (Ø x H) Kunststoff-Haube Ø 300 x 71 mm Ø 300 x 71 mm
Glas Ø 300 x 86 mm
Netzanschluss 230-240 V, 50/60 Hz 230-240 V, 50/60 Hz
Leistungsaufnahme 16 W (1,6 W Dimmbetrieb) 16 W (1,6 W Dimmbetrieb)
Lichtfarbe 3000 K (WW) / 4000 K (KW) 4000 K (KW)
Lichtstrom/Effizienz PC (KW) 734 lm - 45,70 lm/W PC opal 900 lm - 56,25 lm/W
PMMA (KW) 972 lm - 60,75 lm/W PC klar 1191 lm - 74,44 lm/W
Glas (KW) 887 lm - 55,43 lm/W –
PC (WW) 668 lm - 41,75 lm/W –
PMMA (WW) 950 lm - 59,38 lm/W –
Glas (WW) 808 lm - 50,50 lm/W –
Schutzart IP 20 IP 65
IK-Klasse PC IK07 IK10
PMMA IK03 –
Glas IK02 –
RS PRO LED S1 / RS PRO LED S1 IP 65
HF-Technik 5,8 GHz (reagiert temperaturunabhängig auf kleinste Bewegungen)
Erfassungswinkel 360° mit 160° Öffnungswinkel
Sendeleistung ca. 1 mW
Reichweite Ø 1-8 m
Max. Flächenabdeckung ca. 50 m²
Zeiteinstellung 5 sec. - 15 Min.
Dämmerungseinstellung 2-2000 Lux
Helligkeitsregulierung 10 % Dimmbetrieb
a) die ganze Nacht
b) 10 Min. nach Ablauf der eingestellten Zeit
c) 30 Min. nach Ablauf der eingestellten Zeit
Schutzklasse II
Temperaturbereich -10 bis +50 °C
Betriebsstörungen
SensorLeuchte
ohne Spannung
SensorLeuchte
schaltet nicht ein
SensorLeuchte
schaltet nicht aus
SensorLeuchte schaltet
ohne erkennbare Bewegung ein
SensorLeuchte schaltet trotz
Bewegung nicht ein
Störung
Haussicherung defekt, nicht
eingeschaltet, Leitung unterbrochen
Kurzschluss in der Netzzuleitung
Eventuell vorhandener Netzschalter
aus
neue Haussicherung, Netz schalter
einschalten, Lei tung überprüfen mit
Spannungsprüfer
Anschlüsse überprüfen
Netzschalter einschalten
Dämmerungseinstellung falsch
gewählt
Netzschalter AUS
Haussicherung defekt
neu einstellen
einschalten
neue Haussicherung,
evtl. Anschluss überprüfen
dauernde Bewegung im
Erfassungsbereich
Bereich kontrollieren
Lampe nicht bewegungssicher
montiert
Bewegung lag vor, wurde jedoch
vom Beobachter nicht erkannt (Be-
wegung hinter Wand, Bewegung ei-
nes kleinen Objektes in unmittel-
barer Lampennähe etc.)
Gehäuse fest montieren
Bereich kontrollieren
schnelle Bewegungen werden zur
Störungsmini mierung unterdrückt
oder Erfassungsbereich zu klein
eingestellt
Bereich kontrollieren
Ursache Abhilfe
Leuchte in Dauer-DIM
Keine Funktion
Taster DIM Level
im Install-Modus
Taster DIM Level
Install-Modus deaktivieren
Installation Instructions
Dear Customer,
Congratulations on purchasing your new STEINEL
SensorLight and thank you for the confidence you
have shown in us. You have chosen a pioneering
quality product that has been manufactured, tested
and packed with the greatest care.
Please familiarise yourself with these instructions
before attempting to install the product because
prolonged reliable and trouble-free operation will only
be ensured if it is fitted properly.
We hope your new STEINEL light will bring you
lasting pleasure.
GB
System Components
Wall mount/ceiling mount
HF sensor
Spacer for surface wiring
IP65 sealing plug
DIM-level button for installation purposes
Reach setting
Time setting
Light-level setting
Dip switch
Channel selection
Dimming functions
Snake-eye screws (optional)
Shrouds for partial limiting of the reach
Mains connection cable for concealed wiring
Mains connection cable for surface wiring
Example Applications
The RS PRO LED S1/S1 IP65 is an efficient light that
controls itself. A high-frequency sensor for detecting
persons, a light sensor for identifying the room's light-
ing situation as well as LEDs requiring no maintenance
provide efficient, instantaneous light. The facility of
868-MHz wireless communication (channel selection)
allows several lights to be interconnected in a room,
creating a group. Wireless communication to the next
light functions reliably over a distance of 50 m. All lights
then operate with equal rights and act as one large
light.
Principle
The SensorLight is an active motion detector. The
integrated HF-sensor emits high-frequency electro-
magnetic waves (5.8 GHz) and receives their echo.
The sensor detects the change in echo from even
the slightest movement in the light's detection zone.
A microprocessor then triggers the "switch light ON"
command. Detection is possible through doors,
panes of glass or thin walls.
Detection zones for ceiling mounting:
1) Minimum reach (1 m all round)
2) Maximum reach (8 m all round)
Detection zones for wall mounting:
3) Minimum reach (1 m all round)
4) Maximum reach (8 m all round)
Important: Persons or objects moving towards the
light are detected best.
Note:
The high-frequency output of the HF sensor is approx.
1 mW – that's 1000 times less than the transmission
power of a mobile phone or the output of a microwave
oven.
I
II
approx. 1 mW
approx. 1000 mW
GB