Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety in
accordance with applicable regulations and then sub-
jected to random sample inspection. STEINEL guar-
antees that it is perfect condition and proper working
order. The warranty period is 36 months, starting on
the date of sale to the consumer. We will remedy
defects caused by material flaws or manufacturing
faults. The warranty will be met by repair or replace-
ment at our own discretion. The warranty shall not
cover damage to wear parts, damage or defects
caused by improper treatment or maintenance.
Further consequential damage to other objects is
excluded.
Claims under the warranty will only be accepted if the
unit is sent fully assembled and well packed complete
with a brief description of the fault, a receipt or
invoice (date of purchase and dealer's stamp) to the
appropriate Service Centre.
Repair Service:
Please ask your nearest service
centre how to proceed for repairing
faults not covered by the warranty
or occurring after the warranty
expires.
Declaration of conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2011/65/EC
- R&TTE Directive 1999/05/EC
Installation
Important: Make sure the installation site is
not
subject to
vibration.
Connecting a dimmer will result in damage to the
SensorLight.
1. Hold enclosure against the wall/ceiling and
mark drill holes, paying attention to any existing
wiring in the wall/ceiling.
2. Drill the holes, insert wall plugs (6 mm dia.).
3. Pierce sealing plug for power supply lead.
4. Pass power supply leads through.
5. Screw enclosure into place.
6. Connecting the mains power supply lead (see fig.).
The mains power supply lead is a 3-core
cable:
L = phase conductor (mostly black, brown or grey)
N = neutral conductor (usually blue)
PE = protective earth conductor (green/yellow)
If you are in any doubt, you must identify the cables
using a voltage tester; then disconnect from the power
supply again. Connect phase (L) and neutral conductor
(N) to the terminal. Insulate any PE protective earth
conductor in the power supply cable with adhesive
tape.
Technical specifications
Dimensions (H x W x D): 275 mm dia. x 95 mm
Material: Plastic (base), opal glass (shade)
Mains voltage: 230 – 240 V, 50 Hz
Output: 11 W LED / 510 lm / 46.6 lm/W
Colour temperature: 3000 kelvin (warm white)
LED life expectancy: 50.000 hours
HF-system: 5.8 GHz
Angle of coverage: 360° with 160° aperture angle also through glass, wood and stud walls
Detection reach: 3 m – 8 m all round
Twilight setting: 2 – 2000 lux
Time setting: 5 sec. to 15 min.
IP rating: IP 44
Protection class: II
Power consumption: approx. 0.4 W
Temperature range: -10° C to +40 °C
- 8 -
Important: Reversing the connections will result in a
short-circuit in the light unit or in your fuse box later
on. In this case, you must identify the individual con-
ductors once again and re-connect them. A mains
switch for switching the unit ON and OFF may of
course be installed in the mains power supply lead.
7. Set functions , , .
8. Fit glass shade by turning it clockwise and
secure in place with the grub screw .
Surface wiring:
Surface wiring can be carried out as shown in
diagram I on page 2.
Note:
The sealing plugs must be fitted to attain the
IP rating.
GB
The SensorLight can be put into operation as soon as
it has been connected to the mains power supply and
enclosure has been fitted. When the light is turned
ON manually at the light switch, it switches OFF after
10 secs. for the calibration phase and is then activat-
ed for operation in the sensor mode. It is not neces-
sary to actuate the light switch a second time.
Light-level setting (response threshold)
Factory setting: daylight operation (approx. 2000 lux)
The chosen response threshold
can be infinitely varied from
approx. 2 – 2000 lux.
Control dial = daylight operation (approx. 2000 lux)
Control dial = twilight operation (approx. 2 lux)
The control must be turned fully clockwise when
adjusting the detection zone and performing the walk
test in daylight.
Time setting (switch-OFF delay)
Factory setting: shortest time (approx. 5 sec.)
The light's ON time can be set to any
period from approx. 5 sec. and a
maximum of 15 min. Any movement
detected before this time elapses will
re-start the timer.
Control dial max. = longest time (approx. 15 min.)
Control dial min.= shortest time (approx. 5 sec.)
The shortest time setting is recommended when
adjusting the detection zone and performing a
functional test.
Note: After the light switches OFF, it takes approx.
1 sec. before it is able to start detecting movement
again. The light will only switch ON in response to
movement once this period has elapsed.
Reach setting (sensitivity)
Factory setting: max. reach (approx 8 m)
Reach is the term used to describe
the diameter of the more or less cir-
cular detection zone produced on the
ground after mounting the
SensorLight at a height of 2.5 m.
Control dial max. = reach (approx. 8 m)
Control dial min. = reach (approx. 3 m)
Functions
Ø 3 m – 8 m
5 sec. – 15 min.
2 – 2000 lux
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Steinel RS LED A1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Steinel RS LED A1 in de taal/talen: Alle talen als bijlage per email.

De handleiding is 1,65 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info