13
Functional configuration can be performed
before fitting the sensor unit. If you wish to
change the configuration again after fitting the
sensor unit, the catch must first be released
with a flat-bladed screwdriver and the sensor
unit must be removed (see illustration).
The light fixture automatically switches to
continous operation in this case. On fitting the
sensor unit, an approx. 45 second measuring
phase is initiated on each occasion. The red
LED flashes during this period.
Two settings are available on the device:
Functions
The desired response threshold of the motion
detector is infinitely adjustable between approx.
2 lux to 2000 lux. Adjusting screw set to
means daylight operation at approx. 2000 lux.
Adjusting screw set to means night-time
operation at approx. 2 lux.
The adjusting screw must be set to when
adjusting the detection zone and performing
the function test in daylight.
(factory setting:
daylight operation
2000 lux)
Twilight setting (response threshold)
2 – 2000 lux
(factory setting:
approx. 5 sec.)
Time setting (switch-off delay)
approx. 5 sec. – 20 min.
The desired duration of illumination of the
connected lamp is infinitely adjustable
between approx. 5 sec. to max. 20 min.
Adjusting screw set to – means the shortest
time, approx. 5 sec., adjusting screw set to
+ means the longest time, approx. 20 min.
The shortest time setting is recommended
when adjusting the detection zone and per-
forming the function test.
The built-in sensor for indoors and outdoors
with the size of a light bulb. Newly developed
and uncompromisingly geared to professional
needs: IS D 360, the built-in sensor that fits in-
side all commercially available fitting frames,
since the external dimensions are the same as
those of the light bulb. The unit is equipped with
pyro sensors that detect the invisible heat emit-
ted from moving objects (people, animals etc.).
This detected heat radiation is converted and
switches on connected loads (e.g. a light). No
heat radiation is detected through obstacles
such as walls or panes of glass for example and
consequently no switching occurs.
Principle
12
Installation instructions
GB
Safety warnings
■ The electrical connection lead must be dead
during installation. Therefore, switch off the
power first and use a voltage tester to make
sure the wiring is off circuit.
■ Installation of the built-in sensor involves
connecting it to the mains supply. This work
must therefore be carried out by a specialist
in accordance with the applicable national
wiring regulations and electrical operating
conditions. (
D
- VDE 0100,
A
-ÖVE/ÖNORM
E8001-1,
-SEV 1000)
■ Only use genuine replacement parts.
■ Repairs may only be carried out by specialist
workshops.
Dear customer,
Many thanks for the trust that you have shown
in purchasing your new STEINEL infrared
sensor. You have chosen a high-quality prod-
uct that has been manufactured, tested and
packed with the greatest care.
Please familiarise yourself with these instructions
before attempting to install the sensor because
prolonged, reliable and trouble-free operation
will only be ensured if it is installed and used
properly.
We hope that your new infrared sensor brings
you lasting pleasure.
The site of installation should be at least 50 cm
away from another light because heat radiated
from it may activate the system.
The mains supply lead is a 3-core cable:
L = phase
N = neutral conductor
PE = protective-earth conductor
S1, S2: Connection contacts for operation of
devices between 50 V – 240 V~.
With connection type (1), jumper from L to S1
must be applied.
This eliminates the electrical isolation.
Installation
System components
IS D360
Ceiling fitting frame
Cover / cable grip
Mains module
Sensor unit
Shroud
Securing spring
Twilight setting (2 – 2000 lux)
Time setting (5 sec. – 20 min.)
GB