- 14 - - 15 -
Functions
After the mains connection
has been made, the hous ing
has been closed and the
lens has been applied, the
unit can be commissioned.
Two setting options are
concealed behind the
decorative cover .
Important: perform
time and twilight setting
only with the lens installed.
Switch-off delay
(time setting)
The desired period of oper -
ation of the sensor halogen
light can be adjusted con-
tinuously from approx.
10 sec. to a max. of 15 min.
When the adjustment screw
is at the left stop position,
this means the shortest
time of up to 10 sec. When
the adjustment screw is at
the right stop position, this
means the longest time of
approx. 15 min. It is recom-
mended to select the short-
est time when setting the
detection zone and for the
functional test.
HS 502: HS 152 XENO:
Dimensions (H x W x D): 235 x 220 x 155 mm 235 x 160 x 140 mm
Weight: 2060 g 1400 g
Connection: 230–240 V/50 Hz 230–240 V/50 Hz
Output: 500 W max./ R7S 150 W max./ R7S
Additional switching capacity:
500 W max. *
1)
800 W max. *
1)
300 W max., 400 W max.,
cos ϕ = 0.5 *
2)
cos ϕ = 0.5 *
2)
2 x 58 W each, 4 x 58 W each,
C ≤ 44 μF *
3)
C ≤ 88 μF *
3)
Angle of coverage: 180° horizontal, 90° vertical
Area illuminated by floodlight: 375 cm
2
max. 300 cm
2
max.
Sensor reach: basic setting 1: max. 12 m (factory setting)
basic setting 2: max. 05 m
+ fine adjustment via shrouds 1–12 m
Time setting: 10 sec.–15 min. (factory setting 10 sec.)
Twilight setting: 2–2000 lux (factory setting: 2000 lux)
Enclosure: IP 44
Safety class: I (with earth conductor connection)
Swivelling range of halogen light: vertical: 40°, horizontal: 30°
Temperature range: -20 °C – +50 °C
*1) Filament bulbs, 500 W max. (HS 502) / 800 W max. (HS 152 XENO) operating on 230 V AC
*2) Fluorescent lamp, 300 W max. (HS 502) / 400 W max. (HS 152 XENO) at cos ϕ = 0.5,
inductive load at 230 V AC
*3) Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast
(total capacity of all connected ballasts below the value specified) operating on 230 V AC
Technical specifications
Installation height:
In order to achieve the given
reach of 5/12 m, the instal-
lation height should be
approx. 2 m.
Installation steps:
1. Remove decorative cover
, 2. Insert positioning
screw , 3. Fit sensor halo-
gen light in position, 4. Fold
up installation housing ,
5. Mark drilling holes and
remove sensor-switched
halogen floodlight. 6. Drill
the holes and insert plugs
(6 mm dia.). 7. Insert sealing
plugs. 8. Wire up the supply
and service leads, if required
and connect. 9. Screw
housing firmly into place.
Installation/Wall mounting
a) Connection of the
supply lead
The supply lead consists
of a 3-phase cable:
L = phase conductor
N = neutral conductor
PE = protective-earth
conductor
If in doubt, the cable must
be identified with a voltage
tester. Switch off the cur-
rent again. The phase (L)
and neutral (N) conductors
are to be connected
according to the terminal
assignment. The protective
earth conductor (PE) must
be clamped to the earth
contact ( ).
A mains switch for ON
and OFF switching can of
course be installed in the
mains lead. Alternatively
the sensor can manually be
activated for the selected
time by a normally closed
contact pushbutton in the
power supply.
b) Connection for an
additional consumer:
An additional consumer can
be connected to the sensor
halogen light. Please
observe the maximum
permitted output in this
case (refer to technical
specifications). The cur-
rent carrying conductor of
the consumer is connected
to the terminal marked L'.
The neutral conductor of
the consumer is clamped to
the terminal marked N
together with the supply
lead neutral conductor. The
protective earth conductor
is to be connected to the
earth contact.
Important: if the connec-
tions are reversed, the
appliance may be
damaged.
Flush mounted wiring
flush
mounted
Surface mounted wiring
Supply lead
Service lead
10 sec. - 15 min.
surface mounted
GB