- 12 - - 13 -
y Before undertaking any
work on the unit discon-
nect the mains supply!
y The supply lead to be
connected must not be
live during assembly.
Therefore, first switch
OFF the power and
check that the circuit is
dead by using a voltage
tester.
y The installation of these
units involves connecting
them to the mains supply.
The work must therefore
be carried out in a profes-
sional manner in accor-
dance with the regulations
involving installation and
connection of electrical
appliances specific to
each country (IEE Wiring
Regulations). If in doubt
contact a qualified
electrician.
y Suitable for indoor and
outdoor use (up to 25°
room temperature)
y Do not mount the unit on
surfaces that are normal-
ly easily inflammable.
y The light must be in
a horizontal position
(± 15°).
y The light must be
mounted in such a
way that in all possible
setting angles they are at
least 1 metre from the
surface at which they are
direc ted.
y
If the glass cover breaks,
always fit a new glass
cover before using the
light. A special tempered
glass cover in a thick-
ness of 4 mm is required
for HS 152 and in a
thickness of 5 mm for
HS 502. You can order
replacement glass covers
from our service network.
y To avoid inflammation of
the skin and eyes do not
expose yourself for any
length of time to a sensor
halogen light being
operated at 10% over
the nominal voltage.
y The floodlight housing
becomes very hot during
operation. Only align the
floodlight when the
housing has cooled
down.
Safety notification
Appliance description
Safety screw
Decorative cover
Lens (removable and
rotatable to select the
reach – basic setting
of max. 12 m or 5 m)
Twilight setting
2–2000 lux
Time setting
10 sec.–15 min.
Housing folds up for
installation and mains
connection
Positioning screw mount
Maintenance/care
The sensor halogen light is
suitable for automatic
switching of lights. The unit
is not suitable for special
burglar alarm systems,
since it lacks the sabotage
protection prescribed for
this purpose. Weather can
affect operation of the
sensor halogen light.
Strong gusts of wind, snow,
rain and hail can cause
switching errors, since the
sudden temperature
fluctuations cannot be
distinguished from heat
sources.
The detection lens can be
cleaned with a damp cloth
(without detergents) if dirty.
Installation instructions
Dear customer,
Thank you for the confi-
dence that you have placed
in us in purchasing your
new STEINEL sensor-
switched halogen floodlight.
You have decided on a high
quality product, manufac-
tured, tested and packed
with the greatest care.
Please familiarise yourself
with these instructions
before installation, since
only correct commissioning
guarantees long, reliable
and trouble-free operation.
We hope you enjoy your
new appliance.
Principle
Important: The most reliable
motion detection is achieved
by mounting the unit diago-
nally to the direction of
movement and ensuring that
no obstacles (such as trees
or walls) obstruct the line of
sight.
Max. reach 12 m Max. reach 5 m
Walking direction: frontal Walking direction: diagonal
The sensor halogen light is
equipped with two 120°
pyro sensors which detect
the invisible infrared heat
emitted by moving objects
(pedestrians, animals, etc.).
The heat thus detected is
electronically converted and
therefore switches the light
ON. No heat radiation is
detected through obstacles,
such as walls or glass and
no switching therefore
occurs. With the aid of the
two pyro sensors, a detec-
tion angle of 180° (with an
opening angle of 90°) is
achieved.
The lens is removable and
can be rotated. This allows
two basic reach settings of
max. 12 m or 5 m.
GB