592489
6
Verklein
Vergroot
Pagina terug
1/51
Pagina verder
Installation
To make the assembly procedure easier, please fit
the bracket for mounting the support plate after
installing the base .
Connecting the mains power supply lead (see Fig.).
The mains lead consists of a 3 phase cable.
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
If in doubt, a voltage detector must be used to identify
the lead; then switch off the power again.
Important: Reversing the connections will result in
a short-circuit in the light unit or in your fuse box
later on. In this case, you must identify the individual
conductors once again and re-connect them. A mains
switch for switching the unit ON and OFF may of
course be installed in the mains power supply lead.
Important: Make sure the installation site is
not sub-
ject to
vibration.
Connecting a dimmer will result in damage to the
SensorLight.
Please note that the light must be protected by a 10 A
circuit breaker.
Technical specifications
Output: 2 x 18 watts
plus 200 W max. (e.g. bathroom/WC fan extractor)
Mains power connection: 230 – 240 V/50 Hz
Installation site: indoors, ceiling mounting
HF-system: 5.8 GHz CW radar, ISM band
Transmission power: approx. 1 mW
Detection: 360°, 160° angle of aperture, if necessary through glass, wood and stud walls
Reach: 1 – 8 m dia., infinitely variable
Time setting: 1 min. to 15 min.
Twilight setting: 2 – 2000 lux
Enclosure: IP 65
Protection class: I
Power consumption: approx. 0.9 W
- 10 -
L’ Connection of an additional load:
An additional load with max. 200 W can be connected
to the SensorLight, switched by the electronics. Screw
the live conductor to the load into the terminal mar-
ked L’ on the SensorLight. Clamp the neutral conduct-
or in the terminal marked N together with the neutral
conductor of the mains power supply lead. Attach the
protective-earth conductor to the earth terminal.
The SensorLight can be put into service after mount-
ing the light and connecting it to the mains power
supply. When putting the light into operation manually
at the light switch, it will switch off after 10 sec. for
the calibration phase and is then activated for sensor
mode. It is not necessary to actuate the light switch a
second time.
Reach setting (sensitivity)
Reach is the term used to describe
the diameter of the more or less
circular detection zone produced
on the ground after mounting the
SensorLight at a height of 2.5 m.
Turn the reach control fully anti-
clockwise to select minimum reach
(approx. 1 m dia.), and fully clockwise to select max-
imum reach (approx. 8 m dia.). (The light leaves the
factory set to maximum reach.)
Time setting (switch-off delay)
The light can be set to stay ON for
any period of time between approx.
1 min. (control turned fully anti-
clockwise) and a maximum of 15 min.
(control turned fully clockwise).
(The light leaves the factory set to
the shortest time.) Any movement
detected before this time elapses will re-start the
timer. It is recommended to select the shortest time
for adjusting the detection zone and for performing
the walk test.
Note: After the light switches OFF, it takes approx.
1 second before it is able to start detecting movement
again. The light will only switch on in response to
movement once this period has elapsed.
Twilight setting (response threshold)
The chosen light response threshold
can be infinitely varied from approx.
2–2000 lux. Turn control fully anti-
clockwise to select dusk-to-dawn
operation at about 2 lux. Turn control
fully clockwise to select daylight
operation at about 2000 lux. (The
light leaves the factory set to daylight operation.) The
control must be turned fully clockwise when adjusting
the detection zone and performing the walk test in
daylight.
Recommendation:
Fluorescent tube manufacturers recommend season-
ing, or burning in, new tubes for 100 hours so as not to
restrict tube service life. To follow this recommendation
and to ensure trouble-free sensor operation particularly
at low ambient temperatures, new fluorescent tubes
should undergo the following seasoning procedure.
Functions
- 11 -
1 m – 8 m dia.
Functional warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety
in accordance with applicable regulations and then
subjected to random sample inspection. STEINEL
guarantees that it is in perfect condition and proper
working order. The warranty period is 36 months
and starts on the date of sale to the consumer. We
undertake to remedy faults caused by material or
manufacturing defects. This warranty undertaking
shall be performed by the repair or replacement of
the defective parts, at our own discretion. The war-
ranty shall not cover damage to wear parts, damage
or defects caused by improper treatment or mainten-
ance. Further consequential damage to other objects
shall be excluded.
Claims under the warranty will only be accepted if the
unit is sent fully assembled and well packed with a
brief description of the fault, a receipt or invoice (date
of purchase and dealer's stamp) to the appropriate
Service Centre.
Repair Service:
Our Customer Service Department will
repair faults not covered by warranty
or after the warranty period. Please
send the product well packed to your
nearest Service Centre.
Declaration of Conformity
This product complies with Low Voltage Directive
06/95/EC, EMC Directive 04/108/EC, RoHS Directive
02/95/EC, RTTE Directive 99/05/EC and Energy
Efficiency Directive 00/55/EC.
1 min. – 15 min.
2 - 2000 lux
1. Connect light and switch ON
2. Turn all 3 setting controls fully clockwise, then turn
the middle setting control fully anticlockwise and fully
clockwise again (within 10 sec.)
3. The seasoning process is confirmed by switching the
light OFF twice and then back ON again.
4. Now turn all controls to the chosen settings.
5. The light is now left ON for 100 hours without sensor
function. Do not disconnect the light from the mains
power supply during this period.
6. After 100 hours, the light automatically switches to
the sensor mode previously selected in step 4.
Note:
When fluorescent tubes are new or at low ambient
temperatures, the sensor may not switch the light OFF
as it might be detecting gas moving inside the tubes. In
this case, switch the light OFF and, for the time being,
drastically reduce the reach setting.
GB
Removing base
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Steinel FRS 30 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Steinel FRS 30 in de taal/talen: Alle talen als bijlage per email.

De handleiding is 3,4 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info