Press the ENTER key to accept the displayed value. The Information Window will return to the Calibrate Scale menu.
Proceed to step 6.
5. To calibrate the weight scale using the calibrated weight set:
■
Press the key. The Information Window will display the message “PLACE CAL WEIGHT ON WEIGHT PADS”,
followed by the message “PRESS ENTER TO BEGIN”.
■
Place the calibrated weights (125 lbs. per weight) on the weight scale, then press the ENTER key. The Information
Window will display the message “CALIBRATING”.
■
When calibration is complete, the Information Window will display the message “WEIGHT ###”, followed by the mes-
sage “ENTER TO ACCEPT -STOP TO REJECT”.
■
Press the ENTER key to accept the displayed value. The Information Window will return to the Calibrate Scale menu.
Proceed to step 6.
6. Press the key. The Information Window will display the message “REMOVE WEIGHT ON WEIGHT PADS”, followed
by the message “PRESS ENTER TO BEGIN”.
7. Remove the calibrated weights from the weight scale, then press the E
NTER key. The Information Window will display
the message “CALIBRATING”.
8. When calibration is complete, the Information Window will display the message “WEIGHT ###”, followed by the message
“ENTER TO ACCEPT -STOP TO REJECT”.
9. Press the ENTER key to accept the displayed value. The Information Window will return to the Calibrate Scale menu.
10. Press the key. The Information Window will display the message “WEIGHT = 0”. Stand on the weight scale and ver-
ify the Information Window displays your correct weight. Step off the weight scale.
11. Place the calibrated weights on the weight scale and verify the Information Window displays 250 pounds, or, stand on
the weight scale and verify the information window shows your correct weight.
12. Press the S
TOP key to exit the Calibrate Scale function.
SPEED CALIBRATION
The Speed Calibration function allows for calibration of the treadmill's speed function. To enter the Speed Calibration function:
1. While in the Maintenance Settings mode, press the key.
2. The Information Window will display the message “ABC D E”, where ABC is between “233” and “241” (representing
digital elevation at zero level), D is “3” and E is “0”.
3. Press the key. The Information Window will display the message “CAL 3 0”. The treadmill belt will begin mov-
ing as auto-calibration starts.
4. Verify the values in the Information Window changes as the treadmill speed reaches maximum (~10 mph) and returns
to zero. When calibration is complete, the Information Window will display the message “CAL 3 0”.
5. Press the S
TOP key to exit the Speed Calibration function.
ELEVATION CALIBRATION
The Elevation Calibration function allows for calibration of the treadmill's elevation function. To enter the Elevation Calibration
function:
1. While in the Maintenance Settings mode, press the key.
2. The Information Window will display the message “ABC D E”, where ABC is between “233” and “241” (representing
digital elevation at zero level), D is “3” and E is “0”.
3. Press the key, as necessary, until the treadmill is at zero (0%) elevation. When minimum elevation is obtained, press
and hold the key until a “Z” is displayed in the Information Window next to the value in the “ABC” field; “236Z” for
example.
4. Press the key to accept the displayed value as elevation zero. The “Z” will be removed from the Information Window
display.
5. Press the key until the treadmill is at maximum (15%) elevation. The Information Window will display the message
“ABC D E”, where ABC is between “60” and “70” (representing digital elevation at maximum level), D is “3” and E is “0”.