744243
46
Verklein
Vergroot
Pagina terug
1/53
Pagina verder
Installation and Operating Manual
Stoves selection
PREFACE - QUALITY PHILOSOPHY
You have decided in favour of a SPARTHERM stove - thank you for your con-
fidence in our company. In a world of abundance and mass production, we
connect our name with the credo: "high technical quality combined with a
contemporary style, as well as service for the sake of the customer's satis-
faction and recommendation." We and our trade partners offer you first-class
products that are emotionally moving and also engender feelings of comfort
and security. To ensure this, we encourage you to read the operating manual
carefully so that you can become familiar with your stove and its accessories
quickly and thoroughly. In addition to information on use, these instructions
also include important details on care and operation to guarantee your safety
and to protect the value of your stove as well as useful tips and guidance.
Moreover, we show you how you can operate your stove in an environmen-
tally responsible manner. For further enquiries, please contact your specialist
dealer.
We hope you enjoy your new stove.
The SPARTHERM team
G.M. Rokossa
GB 3
OVERVIEW OF INSTALLATION AND OPERATING MANUAL // STOVE SELECTION
1. General instructions 4
1.1 Certified quality 4
1.1.1 Scope of delivery 4
1.1.2 Damage while in transport 4
2. Installation instructions 5
2.1 Basic installation requirements 5
2.1.1 Installation site 5
2.1.2 Multiple configuration 6
2.2. Transport and alignment aid 6
2.3. Installation/assembly 6
2.3.1 Changing the flue gas connection direction 8
2.3.2 Combustion air supply 9
2.3.2.1 Room-air-dependent 9
2.3.2.2 Separate combustion air supply 10
2.3.2.3 Room-air-independent 13
2.3.3 Fire safety 14
2.3.4 Shut-off device 18
2.3.5 Connecting piece 18
2.3.6 Installing the heat storage stones on top 18
2.3.7 Installation of the water-bearing
components of the SENSO M H2O / PIKO H2O 20
2.3.7.1 Connections of SENSO M H2O / PIKO H2O 20
2.3.7.2 Basic requirements for installation
20
2.3.7.3 Thermal discharge safety device (TAS) 21
2.3.7.4 Thermal pump controller 22
2.3.7.5 Electrical connection 22
2.3.7.6 Integration and heating system 23
2.3.7.7 Return flow temperature boost 25
3. Operating Manual 25
3.1. General information on operation 25
3.2 S-Thermatik Mini 26
3.2.1 Commissioning the S-Thermatik Mini 26
3.2.2 Functional check of S-Thermatik Mini 27
3.3 Function of the rotary-base 28
3.4 Type plate 29
3.5 Operation of the water heat exchanger
Senso H2O / PIKO H2O 29
4. Combustion 29
4.1 Initial commissioning 29
4.1.1 Combustion air regulation 30
4.2 Heating-up / firing 31
4.2.1 Adding wood 31
4.2.2 Hourly wood feed quantity 32
4.3 Controlling heat output 32
4.4 Room heating capacity 32
4.5 Heating in the shoulder seasons/during unfavoura-
ble weather conditions 33
4.6 Chimney fire 33
5. Fuel 33
5.1 CO2 Neutrality 33
5.1.1 Wood storage 34
5.2 Your contribution to environmental protection 34
6. Cleaning and care 34
6.1 Cleaning the combustio chamber/cladding parts 34
6.2 Firebox lining 36
6.3 Maintenance 39
6.3.1 Lubrication manual for door latches with
Smartclose 39
6.3.2
Maintenance of the water heat exchanger SENSO M
H2O / PIKO H2O
40
6.3.3
Venting the water heat exchanger SENSO M H2O /
PIKO H2O
40
6.4
Cleaning the water heat exchanger
SENSO M H2O / PIKO H2O
40
6.5 Türmechanik SENSO S RLU 41
7. Troubleshooting 43
7.1 W
ater heat exchanger SENSO M H2O / PIKO H2O
45
8. General warranty conditions 45
8.1 Area of application 45
8.2 General information 46
8.3 Warranty period 46
8.4 Warranty requirements 46
8.5 Exclusions from the warranty 46
8.6 Elimination of defects / repair 47
8.7 Extension to the warranty period 47
8.8 Spare parts 47
8.9 Liability 47
8.10 Closing remarks 47
9. Technical data 47
10. Commissioning protocol 52
GB 4
1.1 CERTIFIED QUALITY
OUR STOVES ARE TESTED IN ACCORDANCE WITH DIN EN 13240. DECLA-
RATION OF PERFORMANCE IS AVAILABLE AND CAN BE VIEWED AT WWW.
SPARTHERM.COM
These stoves are equipped with a self-closing fire door which means the
door is only opened when the fireplace has to be serviced (e.g. to clean
the combustion chamber or add more fuel). For safety reasons, the closing
mechanism must not be tampered with; furthermore, any such action would
render the warranty and operating licence null and void. The guarantee and
operating licence are also rendered invalid if the customer modified the
technology of any other area of the stove.
1.1.1 SCOPE OF DELIVERY
Fireplace made of Vermiculite / Schamotte
Primary and secondary air supply
Pull-out ash pan or ash box and grate (not all models)
Self-closing fire door with high-temperature-resistant ceramic glass.
Insulated glove*
Rating plate („3.4 Type plate“ on page 29)
Supplied pre-assembled in transport-friendly disposable cardboard
packaging
Heat storage stones (only on CUBO M, PIKO M, SENSO L (optional), PASSO
M, STOVO M)
Pump thermostat, thermal discharge safety device ¾", bleeder (only on
SENSO M H2O, PIKO H2O)
Integrated cleaning system with control lever (only on PIKO H2O)
1.1.2 DAMAGE WHILE IN TRANSPORT
Immediately on arrival, please check the goods delivered (visual inspec-
tion). Note down any possible damage on your delivery note and then please
1. GENERAL INSTRUCTIONS
Please consult your district master chimney sweep before assembling and
installing the stove. He will advise you of building law regulations, the
suitability of your chimney, and will conduct the acceptance procedure for
your stove. The chimney calculation is executed in accordance with DIN EN
13384 with the value triplet specified in this manual („9. Technical data“
on page 46).
Important for small children, elderly or infirm persons: As is the case with
all other heating devices, it is expedient that you attach a protective fixture
for these groups of persons, as the view pane and the cladding parts of the
stove can become extremely hot!
Danger of burn injuries!
Never touch the stove when the fire is burning or has just been extin-
guished! The stove should never be operated for an extended period of time
unattended.
The enclosed heat protection glove is exclusively designed to acti-
vate the operating handle and the “cold hand”. The glove is not
fire-proof!
National and European standards, the respective state-specific and local
directives and regulations, and the respective firing installation ordinance
of the German Federal State, must be complied with for setup and operation
of your stove and for the connection to the chimney.
The stove must always be operated with the door closed. Modification of the
closing device is prohibited!
* Important: The glove provided serves only as thermal protection and is not
fireproof.
GB
GB 5
inform your stove fitter. Protect the visible elements of the stove from soil-
ing and damage during installation. Only permitted and sufficiently strong
transport aids may be used to transport the stove.
The following points must be noted to ensure safe and problem-free
transport:
It should be shipped in an upright position or slightly tilted on its back!
Sack trucks used as a transport aid may only carry the stove from the
back.
2. ASSEMBLY INSTRUCTIONS
The assembly and installation of your stove must be carried out by a spe-
cialist. Please consult your district master chimney sweep before assem-
bling and installing the stove to clarify the suitability of the chimney system
and the installation site, and also when having any further questions.
2.1 BASIC INSTALLATION REQUIREMENTS
For installation, connection and operation of the stove, all relevant national
and European standards, as well as local regulations (DIN, DIN EN, state
construction ordinances, firing ordinances, etc.) must be complied with and
applied! The list of regulations given below is not exhaustive.
In the UK all stoves must be fitted in accordance with UK local building and
HETAS regulations. Appliances may only be commissioned by HETAS accred-
ited installers. Only appliances registered with DEFRA may be installed in UK
smoke controlled area.
FeuVo: Feuerungsverordnung (Firing Installation Ordinance) of the respec-
tive German Federal State
LBO: Regional building regulations and fire regulations of
VKF: VKF (Switzerland)
LRV: (Switzerland)
1. BlmschV: Erste Verordnung zur Durchführung des Bundes-Immis-
sionsschutzgesetz (First Ordinance on the Implementation of the Federal
Emissions Control Act)
TROL: Technical Rules of Tiled Stoves and
Hot Air Heating System Trade (ZVSHK)
DIN 1298 / EN 1856: Connecting flue pipes for heat generating systems
DIN EN 13240: Roomheaters fired by solid fuel
DIN 18896: Fireplaces fired by solid fuel Technical rules:
for installation and operation
DIN EN 13384 Chimneys: Thermal and fluid dynamic calculation methods
DIN 18160-1/2: Chimneys/house chimneys
DIN 4751 / DIN EN 12828: Heating systems in buildings –
Design for water-based heating systems
VDI 2035: Water treatment for heating systems
Art. 15a: B-VG (Austria)
Fireplaces may only be installed in rooms and places where the location,
construction situation and type of utilisation do not lead to hazards. The
floor area of the installation must be of a design and size so that the fire-
place can be operated properly and as intended.
2.1.1 INSTALLATION SITE
Your stove must not be installed:
1. In stairways, unless they are in residential buildings with two or fewer
flats.
2. In hallways with general access.
3. In garages.
4. In Fireplace systems in rooms or flats that are ventilated through venti-
lation systems or warm air heating through the use of fans, unless the
safe operation of the stove is ensured.
5. In rooms in which highly combustible or potentially explosive substances
or mixtures are processed, stored or manufactured in quantities that
GB 8
Make sure that the sealing elements are correctly positioned under the
dummy cover and the flue gas outlet and ensure a tight seal. After screwing
in tight, fit the optional storage elements and convected air gate to prevent
airflow in reverse order and fit the lining elements (Fig. 8).
Note: The installation steps may be different depending on each stove model.
Special notes on the Piko H20 model
The Piko H20 model has gas evacuation to the side and to the top in addition
to the option of connecting the connecting piping around a corner. If the
installation situation of the Piko H2O stove has been decided already during
the planning phase, it is possible to order the stove with preassembled
matching flue gas outlet from the factory.
If the orientation of the flue gas outlet on site has to be changed, please
proceed as follows:
Installation from the top to the back/side
The flue gas outlet can be connected to the back in three different positions:
Carefully remove the top plate (A) (Fig. 9) of the stove and place it in a
protected place. When removing the top plate, ensure that the fitted dummy
cover (B) (Fig. 10) does not fall and get damaged.
A
B
C
D
EC
E
A
BC
D
E
C
E
A
BC
D
EC
E
A
BC
D
EC
E
A
BC
D
EC
E
A
BC
D
EC
E
A
B
C
D
EC
E
A
BC
D
EC
E
Fig. 1
Fig. 5
Fig. 2
Fig. 6
Fig. 3
Fig. 7
Fig. 4
Fig. 8
2.3.1 CHANGING THE FLUE GAS CONNECTION
DIRECTION
The stove is prepared for the flue gas connection at the top when delivered.
Depending on the model, the flue gas connection position can be changed
so that it is aligned to the back, to the side or around corners. Follow these
installation steps when changing the flue gas connection position:
Changing the flue gas connection direction from to the top to the
back using the example of the Senso S
Installation from the top to the back
Remove the top plate (A) (Fig. 1) of the stove carefully and place it in a
protected place. When removing the top plate, ensure that the fitted dummy
cover (B) (Fig. 1) does not fall and gets damaged. Depending on the model,
the top plate of the stove must be removed either upwards in advance or
unlocked by parallel displacement to the front (model Stovo).
In stoves with fitted heat storage stones (for example, Cubo / Piko M (Fig.
2)) or convected air regulation (Fig. 3), these components must be removed
(„2.3.6 Installing the heat storage stones on top“ on page 18).
After removing the top plate, the flue gas connection piece (C) (Fig. 4)
bolted onto the stove body is visible. Remove these by loosening the internal
hexagonal bolts (SW 13). Now remove the dummy cover (D) (Fig. 5) on the
back of the covering panel for feed-through of the flue gas pipe. Depending
on the model, the perforation for this must be broken through or 2 fixing
screws loosened.
The only visible dummy cover (E) (Fig. 6) must be unscrewed using the
internal screws (SW13) and replaced with the previously removed flue gas
outlet (C) (Fig. 4). Fit the removed dummy cover (PE) onto the upper flue gas
outlet in order to close this (Fig. 7) (screw connection SW13).
GB 12
Companion dimensions of a stove with SQL coupling
For dimension A and dimension B, see point „2.3 Installation/assembly“
on page 6.
Dimension C:
Distance from the mounting wall to the centre air supply hole. Ensure the
clearances of the flue pipe connection to the chimney are complied with!
Stove
Date of
construc-
tion
Order no.
C in mm
Bore Ø 100 mm
for a combus-
tible mounting
wall
for a mounting
wall that is not
to be protected
Senso S from
11/2014 1033724 308 258
Passo XS 1033726 286 286
Passo S
from
07/2015
1033727 340 290
Passo M 1034352 340 290
Passo L 1035352 340 290
Cubo S
from
11/2014
1033728 303 252
Piko S 1033728 302 252
Cubo M 1033726 309 259
Piko M 1033726 309 259
Cubo L 1033726 309 259
Piko L 1033726 309 259
Redoro S 1037704 302 252
Redoro M 1037704 302 252
Fig. 16
B
A
C
GB 26
activate the operating handle and the “cold hand”. The glove is
not fire-proof!
The stove may only be operated with the fire door closed. The door should
be kept in a cold state is always closed. Only open the door for firing,
refueling and cleaning!
The fireplace must never be modified! In particular, never insert any instal-
lation components into the combustion chamber, combustion air passages
or flue gas flue that have not expressly approved by Spartherm. Your
fireplace warranty and operating permit will be rendered invalid by any
fireplace modification that has not been approved.
You may find that extractor hoods, ventilation equipment, etc. installed in
the same room (or linked space) as your fireplace or stove have a negative
effect on the operation of the Kaminofen (such as the release of smoke
into the room). These devices should not be used at the same time as your
fireplace or stove, without first ensuring that the necessary room heating
system precautions have been taken. („2.3.2.3 Room-air-independent“)
In particular when operating several fireplaces in a single room or linked
space, ensure that sufficient air is available for complete combustion!
This is a temporary fire area thus, longer continuous burning is not
achieved by piling up the fire repeatedly. Continuous burning without piling
up the fire in-between cannot be achieved even through withdrawal of
the combustion air and is also not permitted. A longer heating period is
achieved by repeatedly restoking the fire with suitable amounts of fuels.
Only non-combustible materials must be placed in the lower compartment
of the cladding!
3.2 S-THERMATIK MINI
Supply voltage: 230 V / 24V (via
wall plug transformer)
Power consumption during operation approx. 10 VA
Power consumption in "Stand-by": ca. 6 VA
Safety class: III (safety extra-low voltage)
Degree of protection: IP 50
The S-Thermatik Mini combustion control is pre-set to your stove ex-factory.
Changes to the control parameters must only be carried out by an installer
/ stove fitter or the customer services. Please also follow the accompanying
service instructions!
3.2.1 COMMISSIONING THE S-THERMATIK MINI
In order to guarantee an optimum and trouble-free operation of the fire area,
the door contact switch must be kept free from dirt and grime.
Before opening the fire door, make sure that the selector switch points to
"automatic" when the combustion air control is switched on. In automatic
operation, the control is activated from the stand-by by opening the fire
door. Now the actuator motor runs the dosing facility for the combustion
air to the position "open". The logs are placed and ignited (see also "4.
Combustion"), the firebox door closed. Then, the combustion air is set and
controlled automatically via the actuator motor on the basis of the flue gas
temperature measured.
If the flue gas temperature is below 50°C after 10 minutes (after closing the
combustion chamber door), the combustion air is closed again by the control
without further signals. The air control lever moves to the left.
Heat-up errors: flue gas temperature is above 50°C but the pre-set minimum
temperature for starting the control is not reached: If the flue gas tempera-
ture then drops below 50°C, the combustion air supply is closed for another
15 minutes. An audible signal sounds. Reasons for a heat-up error could be
that not enough, too much, too large or fuel that is too moist has been added,
or the water heat exchanger pipes are blocked.
If there is a heat-up error and the flue gas temperature continues to increase,
the combustion air supply is throttled depending on the exhaust gas temper-
ature. Thus, the primary air (flows over the grate in the combustion chamber)
is closed first and then the secondary air is reduced (differential combus-
tion air setting). In doing so, the combustion air lever moves from the right
GB
GB 27
approximately to the middle in steps. In the further course of combustion
and when the flue gas temperature drops, the combustion air quantity is
reduced further.
In doing so, the combustion air lever moves from the middle further to the
left.
Once the flue gas temperature has dropped far enough so that only embers
are in the combustion chamber, you are prompted to add fuel by an audible
tone. If the audible tone is not desired, this can be switched off by means
of the rocker switch. After the signal, you have approx. 10 minutes to add
more fuel without having to use a firelighter. If fuel is added and the fire
door is opened, the control opens the combustion air supply completely to
100% again. In doing so, the air control lever moves back completely to the
right again.
If no fuel is added after the flue gas temperature has dropped even further,
the combustion air is closed to a minimum. After the period of maintaining
the embers, the combustion chamber can be ventilated by opening the com-
bustion air for three minutes. This function allows the ember bed to reduce
further. After the venting process, the combustion air is
closed completely (0%) and the control shifts to standby mode (control
display off).
The correct operation of the S-Thermatik Mini combustion control is indi-
cated by a maintenance-free signal lamp that is mounted behind the fire
symbol in the bottom area of the stove and indicates the movement of the
air control lever.
If the air control lever does not move after opening the fire door, then S-Ther-
matik Mini mode must be carried out manually using a mechanical release
(changeover of the selector switch) to"manual" mode. The selector switch is
located on the supply air box and is visible when the lower front cladding of
the stove is opened. The combustion air can be adjusted by hand via the air
control lever. For more information about manual adjustment, refer to "4.1.1
Combustion air regulation".
The fireplace insert must never be put into operation with the
combustion air supply (combustion air lever all the way to the left)
closed!
Heat-up errors and the prompt for adding fuel are indicated by an audible
signal. The acoustic signal can be switched off using the rocker switched
mounted on the control housing.
3.2.2 FUNCTIONAL CHECK OF S-THERMATIK MINI
When commissioning the control each time (inserting the wall plug trans-
former into the socket or when shifting the selector switch from manual to
automatic), this carries out a self test when the fire door is closed. In doing
so, the air control lever moves from the left to the right and after a rest
period of max. 1 minute, back to the left again. The air control lever only
moves to the left if the door contact and the flue gas temperature sensor are
functional. The self test should be carried out when the combustion chamber
is cold. When the combustion chamber is hot, the air control lever does not
move completely to the left, it takes the respective position according to the
current flue gas temperature. When the stove is cold and after this self test,
the control shifts to stand-by mode and "waits" until the fire door is opened.
To perform the self-test on your own:
Move the selector switch to manual
Insert the wall plug transformer into the socket
GB
GB 39
6.3 MAINTENANCE
The door seal should be checked regularly. This seal must be replaced if neces-
sary (in case of wear, breakage, etc.). The combustion chamber liner is made of
natural products and must therefore be checked at regular intervals.
As long as the combustion chamber liner maintains the position in the
combustion chamber and does not break, it is fully functional. A crack in
the fireclay brick is therefore no need for a complaint. To ensure proper
functioning, it is essential that an annual (if possible before the heating
season) maintenance of the stove be carried out by a specialist!
Furthermore, the following applies to room air independent stoves:
Proper door seal is an essential item for room-air-independent operation of
the stove. Check the seal for optical characteristics (pressure, wear, bulges)
at least once per heating season and replace it immediately if damaged.
The fireplace must never be modified! Only original spare parts that have
been approved by the manufacturer may be used! If you have any questions,
please contact your specialist dealer.
6.3.1 LUBRICATION MANUAL FOR DOOR LATCHES
WITH SMARTCLOSE
Stoves with SmartClose door locking mechanisms must be lubricated at reg-
ular intervals to assure problem-free operation (once per heating season).
For this purpose, the scope of delivery of
each fire area includes a tube of special
stove lubrication compound.
This lubricating compound is applied to
facilitate ease of movement of heavy fire
doors, and to prevent noise caused by
opening and closing those fire doors. The
lubricating compound must be applied at
least once a year to the spring connection
on the SmartClose and its asso-
ciated roller. With fire areas used
frequently or very frequently, it
may be necessary to shorten this
lubrication interval. Depending
on the type of stove, the door
lock springs may be located
below and/or above the fire door.
In order to lubricate the lock,
you may use a standard cotton
swab/Q-tip as an aid.
To apply the lubricant compound,
proceed as follows:
Open and secure the fire door; Apply a little lubricant compound to the cotton
swab (see Fig. 1) and use it to coat the spring support on the door lock; Turn
the locating roller on the body of the stove during this application process
(see Fig. 2). Open and close the fire door a few times and, if necessary, apply
the lubricant compound once again.
Caution: Ensure that no
copper lubricant compound
makes contact with clad-
ding parts or similar items!
Remove dirt and grime
straightaway with a cotton
cloth. Never operate the
equipment during interven-
ing periods.
Spring seat
Take-up rollers
GB
GB 41
M H2O, and this unavoidably results in deposits on the surfaces of the heat
exchanger, these surfaces must be cleaned with the provided brush on a regular
basis.
The water heat exchanger is cleaned through the cleaning opening. To do this,
open the upper cladding door and remove the cap by removing the wing nuts.
Now the heat exchanger surfaces are exposed and can be cleaned with the
supplied cleaning brush.
The assembly occurs in the reverse order: First put the cap on the cleaning
opening and re-attach the wing nuts.
Piko H2O
Because the water heat exchanger directly cools down the flue gases of the
Piko H2O, and this unavoidably results in deposits on the surfaces of the
heat exchanger, these surfaces must be cleaned with the provided brush
on a regular basis.
The operating handle of the cleaning mechanism is included in delivery and
must be inserted in the 20mm hole on the top left side of the unit when
cleaning. After inserting it, it must be twisted about 5 times to the right and
left to the stops (approximately 20°angle of rotation).
A = remove wing nuts, remove
cleaning cover
B = remove deposits in the pipes
und on the surfaces!
View from front
6.5 DOOR MECHANISM SENSO S RLU
The locking mechanism, in particular the spring force of the closing mecha-
nism, is preset at the factory so that the door closes ideally.
If it is necessary to increase the closing force (door does not close automat-
ically), proceed as follows:
To access the door mechanism, it is necessary to open the bottom inspection
flap (Fig. 29). After opening it, the closing mechanism is visible on the hinge
side of the fire door.
To tighten the mechanism, close the fire door and put a hexagon wrench
(wrench size 24) on the key adapter (1) the drive shaft
Now turn the drive shaft to the left to increase the spring force (Fig. 30).
This should be done in small increments (without gear travel). Then check
the function of the door mechanism. Optimum locking function is guaranteed
if the catch on door wing locks into place and the door closes flush against
the body.
Fig. 29 Fig. 30
GB 44
7.1 WATER HEAT EXCHANGER SENSO M H2O / PIKO H2O
Thermal discharge safety device trips constantly (constant water out-
flow through the discharge). The water heat exchanger cannot dissipate
heat to the heating system.
The buffer tank is "full"  Remove heat from the tank.
Check function and settings of the pump thermostat and the return flow
boost.
Set the pump one level higher (higher flow rate).
Circulation pump does not run. Power connection defective?
Venting the the stove:
Check system pressure.
During first usages, water escapes in the field of garden soil.
If the stove and the heating systems was tested under pressure after installation,
the water discharged is condensate from the fuel and the combustion chamber
liner. If more than 0.2 litres of water accumulate, then the heating system pres-
sure must be tested.
Gurgling noises in the water heat exchanger.
Air in the system, check the system pressure.
Ventilate system via the vent. For newly filled or topped up systems it takes
some time for all the air to collect. Often ventilating once does not suffice.
Thermal discharge safety device drips.
Flush the thermal discharge safety device by activating the red button on
the fitting.
Check the seat of the connection seals and the piston (see the manual
thermal discharge safety device).
If necessary, integrate filter in the system upstream of the discharge safety
device (pay attention to the minimum flow rate!)
Radiators do not warm up. Radiators that are not located in the instal-
lation room are cold.
Close radiator thermostats when the set room temperature is reached. The
convection heat of the fireplace is distributed in the air composite.
Depending on the configuration the heating system is sluggish. It takes some
time until the heating system dissipates its heat.
Have the heating system hydraulically calibrated.
Check that the heating circulation pump is functioning.
Increase the amount of fuel.
Increasing and faster contamination of the combustion chamber lining
and of the glass ceramics. The combustion chamber lining no longer
burns free. Fire can only be ignited with difficulty
Remove deposits in the heat exchanger and in the connecting line to the
chimney. Remove deposits in the heat exchanger and in the connecting line
to the chimney.
Check that the pump thermostat is functioning properly.
Pay attention to correct firing, wood feed quantity, wood moisture content
< 20%.
Correct the position of the air control lever.
Check that the return riser is functioning properly.
Fast contamination of exhaust gas flue in the water heat exchanger.
Inadequate fire behaviour.
Check the return riser.
Pay attention to correct firing, wood feed quantity, wood moisture content
< 20%.
Remove deposits in the heat exchanger and in the connecting line to the
chimney.Remove deposits in the heat exchanger and in the connecting line
to the chimney.
Check that the pump thermostat is functioning properly.
GB 46
ceramics
Improper handling and/or use
Lack of maintenance
Incorrect installation or appliance connection
Failure to comply with installation instructions and operating instructions
Technical modifications made to the appliance by staff from other companies
8.6 ELIMINATION OF DEFECTS / REPAIR
Independent of any statutory provisions acknowledged as taking precedence
over the terms of this warranty, all necessary repair works resulting from mate-
rial or manufacturing defect shall be carried out free-of-charge and shall not
invalidate the remaining provisions of the warranty. Within the scope of this
warranty promise, Spartherm Feuerungstechnik GmbH reserves the right to
either remedy the fault or replace the device free of charge. The elimination of
defects shall take precedence.
The terms of this warranty shall not extend to any damage or compensation not
covered by statutory provisions.
8.7 EXTENSION TO THE WARRANTY PERIOD
The warranty period shall automatically be extended, where claims made in
respect of these warranty provisions result in the repair or replacement of defec-
tive equipment.
8.8 SPARE PARTS
Only the manufacturer's own components, or replacement parts recommended
and approved by the manufacturer, shall be used for appliance servicing and
repair.
8.9 LIABILITY
Damages and claims for compensation which are not the result of delivery of a
defective appliance from Spartherm Feuerungstechnik GmbH are excluded and
are not part of this warranty promise.
The above shall not include claims made in respect of statutory legal
requirements.
8.10 CLOSING REMARKS
In addition to these warranty conditions and our commitment to them, our
dealers and contractual partners are pledged to assist you in both word and
deed. We expressly recommend that our fireplaces and stoves are regularly
inspected by a qualified technician.
9. TECHNICAL DATA
STOVE WITH WATER-SIDE CONNECTIONS
The water-side connections are at the back, in the bottom area.
*The specified values represent the mean value over a combustion. These
values occur under test conditions when approx. 2.2 kg of wood logs are
burnt per hour.
GB
GB 47
1 The thermal discharge safety device integrated in the heating system will
start when the flow temperature of approx. 95°C is reached!
We reserve the right to make alterations to the technical data contained
herein and accept no liability in respect of any errors made.
Technical data SENSO M H2OPIKO H2O
Water heating output approx. 5.0 kW * 4.6 kW
Perm. working overpressure 3.0 bar 3.0 bar
Max. perm. flow temperature1105°C 105°C
Max. operating temperature 95°C 95°C
Minimum return temperature 60°C 60°C
Water-side resistance at 650 l/h 18 mbar 26 mbar
Minimum throughput of thermal discharge safety device
900 ltr. 900 ltr.
Water content approx. 17 ltr. approx. 29 ltr.
46

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Spartherm Passo bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Spartherm Passo in de taal/talen: Engels als bijlage per email.

De handleiding is 3.7 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Spartherm Passo

Spartherm Passo Gebruiksaanwijzing - Nederlands - 53 pagina's

Spartherm Passo Gebruiksaanwijzing - Nederlands - 44 pagina's

Spartherm Passo Gebruiksaanwijzing - Deutsch - 52 pagina's

Spartherm Passo Gebruiksaanwijzing - Français - 53 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info