744244
17
Verklein
Vergroot
Pagina terug
1/53
Pagina verder
Installation and Operating Manual
Stoves selection
PREFACE - QUALITY PHILOSOPHY
You have decided in favour of a SPARTHERM stove - thank you for your con-
fidence in our company. In a world of abundance and mass production, we
connect our name with the credo: "high technical quality combined with a
contemporary style, as well as service for the sake of the customer's satis-
faction and recommendation." We and our trade partners offer you first-class
products that are emotionally moving and also engender feelings of comfort
and security. To ensure this, we encourage you to read the operating manual
carefully so that you can become familiar with your stove and its accessories
quickly and thoroughly. In addition to information on use, these instructions
also include important details on care and operation to guarantee your safety
and to protect the value of your stove as well as useful tips and guidance.
Moreover, we show you how you can operate your stove in an environmen-
tally responsible manner. For further enquiries, please contact your specialist
dealer.
We hope you enjoy your new stove.
The SPARTHERM team
G.M. Rokossa
GB 3
OVERVIEW OF INSTALLATION AND OPERATING MANUAL // STOVE SELECTION
1. General instructions 4
1.1 Certified quality 4
1.1.1 Scope of delivery 4
1.1.2 Damage while in transport 4
2. Installation instructions 5
2.1 Basic installation requirements 5
2.1.1 Installation site 5
2.1.2 Multiple configuration 6
2.2. Transport and alignment aid 6
2.3. Installation/assembly 6
2.3.1 Changing the flue gas connection direction 8
2.3.2 Combustion air supply 9
2.3.2.1 Room-air-dependent 9
2.3.2.2 Separate combustion air supply 10
2.3.2.3 Room-air-independent 13
2.3.3 Fire safety 14
2.3.4 Shut-off device 18
2.3.5 Connecting piece 18
2.3.6 Installing the heat storage stones on top 18
2.3.7 Installation of the water-bearing
components of the SENSO M H2O / PIKO H2O 20
2.3.7.1 Connections of SENSO M H2O / PIKO H2O 20
2.3.7.2 Basic requirements for installation
20
2.3.7.3 Thermal discharge safety device (TAS) 21
2.3.7.4 Thermal pump controller 22
2.3.7.5 Electrical connection 22
2.3.7.6 Integration and heating system 23
2.3.7.7 Return flow temperature boost 25
3. Operating Manual 25
3.1. General information on operation 25
3.2 S-Thermatik Mini 26
3.2.1 Commissioning the S-Thermatik Mini 26
3.2.2 Functional check of S-Thermatik Mini 27
3.3 Function of the rotary-base 28
3.4 Type plate 29
3.5 Operation of the water heat exchanger
Senso H2O / PIKO H2O 29
4. Combustion 29
4.1 Initial commissioning 29
4.1.1 Combustion air regulation 30
4.2 Heating-up / firing 31
4.2.1 Adding wood 31
4.2.2 Hourly wood feed quantity 32
4.3 Controlling heat output 32
4.4 Room heating capacity 32
4.5 Heating in the shoulder seasons/during unfavoura-
ble weather conditions 33
4.6 Chimney fire 33
5. Fuel 33
5.1 CO2 Neutrality 33
5.1.1 Wood storage 34
5.2 Your contribution to environmental protection 34
6. Cleaning and care 34
6.1 Cleaning the combustio chamber/cladding parts 34
6.2 Firebox lining 36
6.3 Maintenance 39
6.3.1 Lubrication manual for door latches with
Smartclose 39
6.3.2
Maintenance of the water heat exchanger SENSO M
H2O / PIKO H2O
40
6.3.3
Venting the water heat exchanger SENSO M H2O /
PIKO H2O
40
6.4
Cleaning the water heat exchanger
SENSO M H2O / PIKO H2O
40
6.5 Türmechanik SENSO S RLU 41
7. Troubleshooting 43
7.1 W
ater heat exchanger SENSO M H2O / PIKO H2O
45
8. General warranty conditions 45
8.1 Area of application 45
8.2 General information 46
8.3 Warranty period 46
8.4 Warranty requirements 46
8.5 Exclusions from the warranty 46
8.6 Elimination of defects / repair 47
8.7 Extension to the warranty period 47
8.8 Spare parts 47
8.9 Liability 47
8.10 Closing remarks 47
9. Technical data 47
10. Commissioning protocol 52
GB 4
1.1 CERTIFIED QUALITY
OUR STOVES ARE TESTED IN ACCORDANCE WITH DIN EN 13240. DECLA-
RATION OF PERFORMANCE IS AVAILABLE AND CAN BE VIEWED AT WWW.
SPARTHERM.COM
These stoves are equipped with a self-closing fire door which means the
door is only opened when the fireplace has to be serviced (e.g. to clean
the combustion chamber or add more fuel). For safety reasons, the closing
mechanism must not be tampered with; furthermore, any such action would
render the warranty and operating licence null and void. The guarantee and
operating licence are also rendered invalid if the customer modified the
technology of any other area of the stove.
1.1.1 SCOPE OF DELIVERY
Fireplace made of Vermiculite / Schamotte
Primary and secondary air supply
Pull-out ash pan or ash box and grate (not all models)
Self-closing fire door with high-temperature-resistant ceramic glass.
Insulated glove*
Rating plate („3.4 Type plate“ on page 29)
Supplied pre-assembled in transport-friendly disposable cardboard
packaging
Heat storage stones (only on CUBO M, PIKO M, SENSO L (optional), PASSO
M, STOVO M)
Pump thermostat, thermal discharge safety device ¾", bleeder (only on
SENSO M H2O, PIKO H2O)
Integrated cleaning system with control lever (only on PIKO H2O)
1.1.2 DAMAGE WHILE IN TRANSPORT
Immediately on arrival, please check the goods delivered (visual inspec-
tion). Note down any possible damage on your delivery note and then please
1. GENERAL INSTRUCTIONS
Please consult your district master chimney sweep before assembling and
installing the stove. He will advise you of building law regulations, the
suitability of your chimney, and will conduct the acceptance procedure for
your stove. The chimney calculation is executed in accordance with DIN EN
13384 with the value triplet specified in this manual („9. Technical data“
on page 46).
Important for small children, elderly or infirm persons: As is the case with
all other heating devices, it is expedient that you attach a protective fixture
for these groups of persons, as the view pane and the cladding parts of the
stove can become extremely hot!
Danger of burn injuries!
Never touch the stove when the fire is burning or has just been extin-
guished! The stove should never be operated for an extended period of time
unattended.
The enclosed heat protection glove is exclusively designed to acti-
vate the operating handle and the “cold hand”. The glove is not
fire-proof!
National and European standards, the respective state-specific and local
directives and regulations, and the respective firing installation ordinance
of the German Federal State, must be complied with for setup and operation
of your stove and for the connection to the chimney.
The stove must always be operated with the door closed. Modification of the
closing device is prohibited!
* Important: The glove provided serves only as thermal protection and is not
fireproof.
GB
GB 5
inform your stove fitter. Protect the visible elements of the stove from soil-
ing and damage during installation. Only permitted and sufficiently strong
transport aids may be used to transport the stove.
The following points must be noted to ensure safe and problem-free
transport:
It should be shipped in an upright position or slightly tilted on its back!
Sack trucks used as a transport aid may only carry the stove from the
back.
2. ASSEMBLY INSTRUCTIONS
The assembly and installation of your stove must be carried out by a spe-
cialist. Please consult your district master chimney sweep before assem-
bling and installing the stove to clarify the suitability of the chimney system
and the installation site, and also when having any further questions.
2.1 BASIC INSTALLATION REQUIREMENTS
For installation, connection and operation of the stove, all relevant national
and European standards, as well as local regulations (DIN, DIN EN, state
construction ordinances, firing ordinances, etc.) must be complied with and
applied! The list of regulations given below is not exhaustive.
In the UK all stoves must be fitted in accordance with UK local building and
HETAS regulations. Appliances may only be commissioned by HETAS accred-
ited installers. Only appliances registered with DEFRA may be installed in UK
smoke controlled area.
FeuVo: Feuerungsverordnung (Firing Installation Ordinance) of the respec-
tive German Federal State
LBO: Regional building regulations and fire regulations of
VKF: VKF (Switzerland)
LRV: (Switzerland)
1. BlmschV: Erste Verordnung zur Durchführung des Bundes-Immis-
sionsschutzgesetz (First Ordinance on the Implementation of the Federal
Emissions Control Act)
TROL: Technical Rules of Tiled Stoves and
Hot Air Heating System Trade (ZVSHK)
DIN 1298 / EN 1856: Connecting flue pipes for heat generating systems
DIN EN 13240: Roomheaters fired by solid fuel
DIN 18896: Fireplaces fired by solid fuel Technical rules:
for installation and operation
DIN EN 13384 Chimneys: Thermal and fluid dynamic calculation methods
DIN 18160-1/2: Chimneys/house chimneys
DIN 4751 / DIN EN 12828: Heating systems in buildings –
Design for water-based heating systems
VDI 2035: Water treatment for heating systems
Art. 15a: B-VG (Austria)
Fireplaces may only be installed in rooms and places where the location,
construction situation and type of utilisation do not lead to hazards. The
floor area of the installation must be of a design and size so that the fire-
place can be operated properly and as intended.
2.1.1 INSTALLATION SITE
Your stove must not be installed:
1. In stairways, unless they are in residential buildings with two or fewer
flats.
2. In hallways with general access.
3. In garages.
4. In Fireplace systems in rooms or flats that are ventilated through venti-
lation systems or warm air heating through the use of fans, unless the
safe operation of the stove is ensured.
5. In rooms in which highly combustible or potentially explosive substances
or mixtures are processed, stored or manufactured in quantities that
GB 6
Attention! The transport and alignment aids may only be used on a stable
subfloor. Soft, delicate floors can be damaged by the high surface pressure
of the transport casters!
2.3 INSTALLATION/ASSEMBLY
Your stove must be installed on floors with sufficient load-bearing capacity.
Please observe the overall weight („9. Technical data“ on page 46)! The
load-bearing capacity may have to be ensured by a sufficiently thick board
(weight distribution).
Observe the necessary measures for fire protection in the floor area when
choosing the installation location. („2.3.3 Fire safety“ on page 14)
Stability "9. Technical data“ on page 6
Stoves with an upright design and fitted heat storage stones must be
secured against unintentional tilting because of their top-heaviness.
The stove is placed on the floor in compliance with the safety distances
(„2.3.3 Fire safety“ on page 14) and aligned horizontally. The feet are
adjustable in height.
Flue pipe elbow kit
Install the stove with the flue pipe bend set that we offer and refer to the
following for the stove-specific connection height dimensions.
Flue pipe elbow kit, colour version
Order no. Unpainted Black Graphite Terra Pearl
-1017770 1017769 1017772 1017771
would be hazardous in the event of ignition or explosion
Room air independent stoves can be placed in rooms, apartments or uti-
lization units of comparable size from which air can be sucked out using
fans such as ventilation or hot air heating systems. The condition is that the
vacuum-capable equipment cannot create a vacuum > 8 PA.
2.1.2 MULTIPLE CONFIGURATION
Multiple use of the chimney in accordance with DIN 18160 is possible
because the stove has a self-closing fire door (A1). All fireplaces connected
to a chimney must also be approved for multiple use!
The following applies to room-air-independent stoves:
A multiple chimney configuration is prohibited!
2.2 TRANSPORT AND ALIGNMENT AID
The Spartherm stoves Moro and Noto with integrated transport and align-
ment aid give you the possibility to move the stove to the installation loca-
tion with little effort and be able to perform the alignment quickly.
To do this, it is necessary to fully screw in the adjustable feet set into the
lower wood compartment to align the stove.
After screwing in the feet, the entire weight load of the stove is supported
by the transport casters set into the base. Now it is possible to move the
stove back and forth.
Please ensure that the fitted natural stone elements do not move or fall off
the stove! After positioning, unscrew the adjusting feet and ensure the stove
is standing securely.
Moro Noto
GB
GB 7
Fig. 1a
Fig. 1b
Stove Bore
Ø 150 mm
A
in mm
B
in mm
Stovo
Stovo S 990 1682
Stovo S plus 990 1682
Stovo M 990 1682
Stovo L 990 1682
Stovo L plus 990 1682
Sino
Sino L 1091 1837
Sino City 1091 1837
Moro 1070 1844
Noto 924 1665
Senso
Senso S 916 1639
Senso S RLU 916 1639
Senso M H2O 1157 1906
Senso L 1138 1882
Senso L 2015 1172 1916
Passo
Passo XS 958 1719
Passo XS RLU 958 1719
Passo S 1147 2015
Passo M 1248 2215
Passo L 1383 2115
Passo S 2015 1282 1880
Passo M 2015 1247 2215
Passo L 2015 1382 1980
Piko
Piko S 973 1712
Piko M / L 1113 1852
Piko M / L with log storage compartment
1113 1852
Piko S RLU 973 1739
Piko M RLU 1113 1852
Piko M RLU with log storage compartment
** **
Piko L RLU 1253 2019
Piko L RLU with log storage compartment
** **
Cubo
Cubo S 973 1712
Cubo M / L 1113 1852
Cubo M / L with log storage compartment
1113 1852
Cubo S 973 1739
Cubo M RLU 1113 1852
Cubo M RLU with log storage compartment
** **
Cubo L RLU 1253 2019
Cubo L RLU with log storage compartment
** **
Redoro
Redoro S 1253 1992
Redoro M 1253 1992
** Data are not yet available
Dimension A: Flue pipe connection height with dis-
charge to the back
Dimension B: Flue pipe connection height with use of
the flue pipe bend set
GB 8
Make sure that the sealing elements are correctly positioned under the
dummy cover and the flue gas outlet and ensure a tight seal. After screwing
in tight, fit the optional storage elements and convected air gate to prevent
airflow in reverse order and fit the lining elements (Fig. 8).
Note: The installation steps may be different depending on each stove model.
Special notes on the Piko H20 model
The Piko H20 model has gas evacuation to the side and to the top in addition
to the option of connecting the connecting piping around a corner. If the
installation situation of the Piko H2O stove has been decided already during
the planning phase, it is possible to order the stove with preassembled
matching flue gas outlet from the factory.
If the orientation of the flue gas outlet on site has to be changed, please
proceed as follows:
Installation from the top to the back/side
The flue gas outlet can be connected to the back in three different positions:
Carefully remove the top plate (A) (Fig. 9) of the stove and place it in a
protected place. When removing the top plate, ensure that the fitted dummy
cover (B) (Fig. 10) does not fall and get damaged.
A
B
C
D
EC
E
A
BC
D
E
C
E
A
BC
D
EC
E
A
BC
D
EC
E
A
BC
D
EC
E
A
BC
D
EC
E
A
B
C
D
EC
E
A
BC
D
EC
E
Fig. 1
Fig. 5
Fig. 2
Fig. 6
Fig. 3
Fig. 7
Fig. 4
Fig. 8
2.3.1 CHANGING THE FLUE GAS CONNECTION
DIRECTION
The stove is prepared for the flue gas connection at the top when delivered.
Depending on the model, the flue gas connection position can be changed
so that it is aligned to the back, to the side or around corners. Follow these
installation steps when changing the flue gas connection position:
Changing the flue gas connection direction from to the top to the
back using the example of the Senso S
Installation from the top to the back
Remove the top plate (A) (Fig. 1) of the stove carefully and place it in a
protected place. When removing the top plate, ensure that the fitted dummy
cover (B) (Fig. 1) does not fall and gets damaged. Depending on the model,
the top plate of the stove must be removed either upwards in advance or
unlocked by parallel displacement to the front (model Stovo).
In stoves with fitted heat storage stones (for example, Cubo / Piko M (Fig.
2)) or convected air regulation (Fig. 3), these components must be removed
(„2.3.6 Installing the heat storage stones on top“ on page 18).
After removing the top plate, the flue gas connection piece (C) (Fig. 4)
bolted onto the stove body is visible. Remove these by loosening the internal
hexagonal bolts (SW 13). Now remove the dummy cover (D) (Fig. 5) on the
back of the covering panel for feed-through of the flue gas pipe. Depending
on the model, the perforation for this must be broken through or 2 fixing
screws loosened.
The only visible dummy cover (E) (Fig. 6) must be unscrewed using the
internal screws (SW13) and replaced with the previously removed flue gas
outlet (C) (Fig. 4). Fit the removed dummy cover (PE) onto the upper flue gas
outlet in order to close this (Fig. 7) (screw connection SW13).
GB
GB 9
After removing the top plate, the flue gas connection piece (C) (Fig. 10)
bolted onto the stove body is visible. Remove it by loosening the internal
hexagonal bolts (SW 13). Then, remove the back cover plate (Fig. 10) using
the screw connection. A blanking plug for the flue gas outlet to the back/
side is visible (E) (Fig. 11) behind the cover plate. Unscrew this.
Now fit the flue gas connection pipe depending on the desired orientation to
the right/left side or straight back. For the right/left side connection type, a
separate connecting piece is supplied with the Piko H20 stove (Fig. 13). The
top connecting piece is used for the back connection type. Ensure that the
underlying caulking strip is placed correctly and seals tightly.
The removed dummy cover (E) is screwed in place as shown in (Fig. 12) and
seals the flue gas outlet at the top.
Finally, close the open cladding openings at the back of the stove with the
enclosed cover plates and fit the top plate (Fig. 14).
2.3.2 COMBUSTION AIR SUPPLY
The combustion air can be supplied in accordance with „2.3.2.1
Room-air-dependent“ and „2.3.2.3 Room-air-independent“ in different
ways
.
2.3.2.1 ROOM-AIR-DEPENDENT
Your stove draws the combustion air from the installation area (room air depend-
ent operation). Ensure that the installation area is adequately supplied with
fresh air (more details in the country-specific FeuVO, DIN 18896, the technical
regulations, etc.). The fresh air supply must be checked by the installer and the
operator. When operating several fireplaces in a single room or linked space,
ensure that sufficient air is available for complete combustion! It is possible that
there is not a sufficient supply of fresh air if the windows and doors are sealed
(e.g., in combination with energy saving measures). As a result, the ventilation
of the tiled stove can be affected. This can adversely affect your well-being
and, potentially, your safety. If necessary, an air valve must be installed near
the pellet stove for the additional supply of fresh air, or a combustion air line
must be routed outwards („2.3.2.2 Separate combustion air supply“) or in a
well-ventilated room (except for the heating room). In particular, ensure that the
Outlet on the left side
A
BC
DE
Outlet to the centre
A
BC
DE
Outlet on the right side
A
BC
DE
A
B
C
DE
Fig. 9
A
B
C
D
E
Fig. 10
A
BC
D
E
Fig. 11
A
BC
DE
Fig. 12
A
BC
DE
Fig. 13
A
BC
DE
Fig. 14
GB
GB 17
* The distance is only valid in conjunction with a radiation protection plate on the top plate, which is fitted behind the vertical flue gas pipe.
Stoves Distance to side wall Distance to theback wall Distance in the area of direct radiant heat of
the pane(s).
Dimensions of the fire protection floor
covering
A (cm) B (cm) C (cm) D (cm)
combustible No protection
required
combustible No protection
required
combustible No protection required Length x width Radius (with round floor
covering)
Piko S / Piko S RLU 10 10 10 580 80 50 x 30 50
Piko M / Piko M RLU 10 10 10 580 80 50 x 30 50
Piko L / Piko L RLU 10 10 10 580 80 50 x 30 50
Piko H2O10 10 10 580 80 50 x 30 50
Cubo S / Cubo S RLU 10 10 10 580 80 50 x 30 50
Cubo M / Cubo M RLU 10 10 10 580 80 50 x 30 50
Cubo L / Cubo L RLU 10 10 10 580 80 50 x 30 50
Redoro S / M 10 10 10 580 80 50 x 30 50
Stovo S 31 20 16 580 80 50 x 30 50
Stovo S plus 31 20 16 580 80 50 x 30 50
Stovo M 31 20 16 580 80 50 x 30 50
Stovo L 56 25 13 580 80 50 x 30 50
Stovo L plus 64 25 13 580 80 50 x 30 50
Senso S / Senso S RLU 47 20 10 * 580 80 50 x 30 50
Senso M H2O10 10 10 580 80 50 x 30 50
Senso L / Senso L RLU 45 10 15 580 80 50 x 30 50
Sino L 10 10 8 5 80 80 50 x 30 50
Sino City / Sino City RLU 36 10 7 5 80 80 50 x 30 50
Moro / Moro RLU 35 20 20 580 80 50 x 30 50
Noto 15 15 20 580 80 50 x 30 50
Passo XS / Passo XS RLU 15 15 5 5 80 80 50 x 30 50
Passo S / Passo S RLU 5 5 10 580 80 50 x 30 50
Passo M / Passo M RLU 5 5 10 580 80 50 x 30 50
Passo L / Passo L RLU 5 5 10 580 80 50 x 30 50
17

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Spartherm Passo XS bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Spartherm Passo XS in de taal/talen: Engels als bijlage per email.

De handleiding is 3.7 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Spartherm Passo XS

Spartherm Passo XS Gebruiksaanwijzing - Nederlands - 53 pagina's

Spartherm Passo XS Gebruiksaanwijzing - Nederlands - 44 pagina's

Spartherm Passo XS Gebruiksaanwijzing - Deutsch - 52 pagina's

Spartherm Passo XS Gebruiksaanwijzing - Français - 53 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info