8
EN
2 / INSTALLING YOUR APPLIANCE
••
ELECTRIC CONNECTION
Monophase 20A Counter
220-240V~ 50Hz
Electrical outlet
2 prong receptacle +
eeaarrtthh
CEI Standard 60083
Monophase line 220-240 V ~
Power
supply cable
length 1.50 m approx.
10A fuse or differential
circuit breaker
Electrical safety must be provided by a
correct build-in. During fitting and
maintenance operations, the appliance must
be unplugged from the electrical grid; fuses
must be switched off or removed.
The electrical connection should be
performed before the appliance is installed in
the cabinet.
Ensure that:
- the electrical installation has sufficient
voltage,
- the electrical wires are in good condition
- the diameter of the wires complies with the
installation requirements.
Your oven must be connected with a
(standardised) power cable with
3 conductors of 1.5mm2 (1 live + 1 neutral +
earth) which must be connected to a
220-240V~ single-phase grid via the
intermediary of a 1 live + 1 neutral + earth CEI
60083 standardised power socket or via an
all-pole cut-off device in compliance with the
installation rules.
Warning
The safety wire (green-yellow) is
connected to the appliance’s terminal
and must be connected to the ground lead
of the electrical set-up.
In the case of connection to an electric wall
socket, it must remain accessible after
installation.
The fuse in your set-up must be 10 amperes.
If the power cable is damaged, it must be
replaced by the manufacturer, its After-
Sales Service Department or a similarly
qualified person to avoid danger.