Oven installation
Connection
Electrical connections must be made as per the connection plate fixed to the back of the
appliance, by an electrical fitter, who must ensure that the appliance has been connected
up in accordance with fitting instructions and local regulations.
Where the appliance is not connected to the mains electricity supply by a plug, an omni polar
cutout device (with a contacts gap of at least 3 mm) must be fitted on the supply side of
the connection to meet safety requirements.
NOTE: When power is connected, the electronics of the oven are initialised; this neutralizes
the lighting for a few seconds.
If the oven is connected to the power supply by a plug, this must remain accessible once
the oven has been installed.
We cannot accept any liability in the event of an accident resulting from non-existent or
faulty earthing.
If the power supply cable is damaged, it presents a potential hazard. It must be replaced by
the manufacturer, its after-sales service.
Operating voltage .....................................................................220-240 V ~ 50 Hz
Total wattage of oven .............................................................................2.925 kW
Nominal wattage of grill ............................................................................2.65 kW
Energy consumption
-while heating to 175°C........................................................................0.205 kWh
-to maintain 175°C for 1 hour ................................................................0.410 kWh
TOTAL ..................................................................................................0.615 kWh
Inside dimensions of oven
Width.........................................................................................................43 cm
Height........................................................................................................19 cm
Depth.........................................................................................................38 cm
Effective volume ....................................................................................32 litres
min.
network voltage connection diameter of fuse
cable
230V~ 50Hz 1 Ph + N 1.5 mm
2
16 A