3. turn chain tensioning knob K upwards
until the lowest chain links come up and
JUST touch the bottom of chain bar D
4. tighten locking knob B by turning it clockwise
5. release chain bar
6. the correct chain tension is reached
when the chain can be raised approx. 4
mm from the chain bar in the centre
! 


-upon initial operation, new chains can lengthen
considerably
-the chain life of the saw chain mainly depends upon
sucient lubrication and correct tensioning
-avoid tensioning the chain if it is hot, as this will cause
the chain to become overtensioned when it cools down
Lubrication t
Chain life and cutting capacity depend on optimum
lubrication; therefore the chain is automatically oiled
during operation via oil outlet L 2
! 

! never operate the chain saw without chain oil or

extensive damage to the product
-set chain saw on any suitable surface with oil reservoir
cap M facing upward
-unscrew cap and add chain saw oil (not included) until
reservoir is full
-avoid dirt or debris entering oil reservoir
-mount oil reservoir cap and tighten
! 

indicator N
-the oil reservoir lling will last approx. 15 minutes,
depending on sawing intensity and stops
-never use recycled/old oil
! 
On/o y
-switch on tool by rst pressing safety switch Q and then
pulling trigger switch R
-switch o the tool by releasing trigger R
! 
front hand guard S 2
Kickback brake u
The kickback brake is a safety mechanism activated
through front hand guard S, when kickback occurs ->
chain stops immediately
The following function check should be carried out at
regular intervals:
-push front hand guard S forward and start the chain
saw -> the chain must not start
-to deactivate the kickback brake, release trigger switch
R and pull hand guard S backwards
Operating the tool
-always hold the chain saw rmly with both hands (front
handle T with the left hand and rear handle U with the
right hand); never operate chain saw using only one
hand ia
! 
makes contact with the wood
-use gripping teeth V to secure the saw onto the wood
before starting to cut ia
9 Beware of chain saw kickback and avoid contact with
bar tip
q Always use chain saw two-handed
USE
Assembly instructions w
! 
! 
-place the chain saw on any suitable at surface
-remove cover plate A by turning locking knob B
counter-clockwise
-slide chain C in the slot around chain bar D
-t the chain onto drive sprocket F and guide chain bar
D, so that fastening bolt G and the guide ns H t into
the keyway of chain bar D
! 

-check if all parts are seated properly and hold chain
and chain bar in a level position
-mount cover plate A as illustrated
-if necessary, turn tensioning knob K to bring tensioning
peg J in alignment with the hole in chain bar D
-turn tensioning knob K until all the slack is taken up in
the chain
-tighten locking knob B on fastening bolt G by turning it
clockwise
Charging battery
! 
provided with the charger
Removing/installing the battery 2
Battery level indicator e
-press the battery level indicator button P to show the
current battery level ea
! 
e

! 
e

Battery protection
The tool is suddenly being switched o or prevented from
being switched on, when
-the load is too high --> remove load and restart
-
 --> 2
levels of the battery level indicator start ashing when
pressing button P eb; wait until battery has returned
within the allowable operating temperature range
-
deep discharge) --> a low battery level or ashing low
battery level ec is shown by the battery level indicator
when pressing button P; charge battery
! 

damaged
Tensioning chain r
! 
-place the chain saw on any suitable at surface
-check if the chain links are correctly located in the slot
around chain bar D
1. loosen locking knob B until it is just holding
chain bar in position (do not remove)
2. lift the chain bar somewhat and hold it in that position
16

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Skil 0534 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Skil 0534 in de taal/talen: Alle talen als bijlage per email.

De handleiding is 4,92 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info