This multimeter has been designed according to IEC-61010
concerning electronic measuring instruments with an overvoltage
category (CAT III 600V) and pollution 2.
Only to use for measurements in a 1-phase electrical 600V
installation after the group distribution frame.!!!
Also to use for measurements of electric appliances with a plug
and lighting connected on this installation after the group
distribution frame.!!!

maximum 600Voltage.

meter is used safely and is kept in good ope g condition.

test leads supplied. If necessary, they must be replaced with the
type specified in this manual.

Important safety information, refer to the operating manual.
Dangerous voltage may be present.
Earth ground.
Double insulation (Protection class II).
 Over voltage category II for measurments on electric and
electronic appliances who by way of a plug is provided of
voltage. This catagory enclosed also all smaller catagory’s (for
instance CAT I for measuring of signal and steering tension.




  when a higher degree of reliabilty
and availability is desired.


 Before opening the case, always disconnect test leads from
all energized circuits
 
the specified voltage and current ratings:

 
fastened completely.
 
To clean it using a damp cloth and mild detergent only.


specifications for each range of measurement.

unused terminals.

60V above earth ground in category III installations.

set the range selector at the highest position.

disconnect test leads from the circuit under test.

circuits always remember that there may be high amplitude
voltages pulses at test points, which can damage the meter.

30V AC rms. Keep fingers behind the probe barriers while
measuring.
 



Continuity Test with battery operated.



1. Display

2. Back light (option)


again, just push this button once.

This switch is used to select functions and desired ranges as well

4. Hold button



Plug in connector for red test lead for 10A measurement.
6. “COM” jack
Plug in connector for black (negative) test lead.
ΩmA” jack
Plug in connector for red (positive) test lead for voltage,
resistance and current (except 10A) measurements.

Accuracy is specified for a period of one year after calibration and


Maximum voltage between : CAT III 600V
terminals and earth ground
 
 
 

 
converter
Overrange Indication : Only figure “1” on the display
Polarity indication :“-”displayed for negative polarity
Operating Environment :0 to 40°C
 
  “appears on the display
 
 

  
  
  
  
  
600V 1V ±0.8% of rdg ± 2 digits

rms. AC for other ranges.

  
20μA 0.01μA ±1% of rdg ± 2 digits
2mA 1μA ±1% of rdg ± 2 digits
20mA 10μA ±1% of rdg ± 2 digits
  
10A 10mA ±3% of rdg ± 2 digits


  
200V 100mV ±1.2 % of rdg ± 10 digits
600V 1V ±1.2 % of rdg ± 10 digits
Overload Protection: 600V DC or rms. AC for all ranges.

calibrated in rms. of a sine wave.

 
Ω),
built-in buzzer will sound.

the diode.
DC or rms. AC.

  
200Ω 0.1Ω ±0.8% of rdg ± 3 digits
2kΩ 1Ω ±0.8% of rdg ± 2 digits
20kΩ 10Ω ±0.8% of rdg ± 2 digits
200kΩ 100Ω ±0.8% of rdg ± 2 digits
2MΩ 1kΩ ±1.0% of rdg ± 2 digits
Maximum Open Circuit Voltage: 3.2V
DC or rms. AC for all ranges


1. Connect the red test lead to the “V.Ω.mA” jack and the black
lead to the “COM” jack.

measured is not known beforehand, set range switch at the
highest range position and then reduce it until satisfactory
resolution is obtained.
3. Connect test leads across the source or load being measured.

the red lead connection

1. Connect the red test lead to the “V.Ω.mA” jack and the black

and 10A, remove red lead to“10A” jack.)

3. Open the circuit in which the current is to be measured, and
connect test leads in series with the circuit.

lead connection.

1. Connect the red test lead to “V.Ω. mA” jack and the black test
lead to the “COM” jack.

3. Connect test leads across the source or load being measured.


1. Connect the red test lead to “V. Ω. mA” jack and black test lead
to the “COM” jack. (The polarity of red lead is positive “+”.)
Ω” range position.
2. Connect test leads across the resistor to be measured and read

4. If the resistance being measured is connected to a circuit, turn off
power and discharge all capacitors before applying test probes.

1. Connect the red test lead to “V.Ω.mA” jack and the black test
lead to the “COM” jack. (The polarity of red lead is positive “+”.).
 position.
3. Connect the red test lead to the anode of the diode to be tested
and the black test lead to the cathode of the diode.
4. The approx. forward voltage drop of the diode will be displayed.
If the connection is reversed only figure “1” will be shown.

1. Connect red test lead to “V.Ω.mA”, black test lead to “COM”.
 ” position.
3. Connect test leads to two points of circuit to be tested.
If continuity exists, built-in buzzer will sound.

If “
”appears on display, it indicates that the battery should be
replaced.

operator’s error.


replace with a new one.
Be careful to observe battery polarity.

Before attempting to open the case, always be sure that test leads
have been disconnected from measurement circuits. Close case and
tighten screws completely before using the meter to avoid electrical
shock hazard.









 
Skandia
©









2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Skandia 1088024 - Digitale Multimeter bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Skandia 1088024 - Digitale Multimeter in de taal/talen: Nederlands, Engels als bijlage per email.

De handleiding is 1,06 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Skandia 1088024 - Digitale Multimeter

Skandia 1088024 - Digitale Multimeter Gebruiksaanwijzing - Nederlands - 1 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info