620396
2
Verklein
Vergroot
Pagina terug
1/2
Pagina verder
Settings for automatic operation with 2 comfort periods
Adjustable in operating modes , , and
OK
OK
OK
OK
OK
h
OK
h
OK
° C
OK
OK
h
OK
h
OK
° C
ESC
ESC
/
ESC
ESC
If no button is pressed for 20 seconds, the setting
displayed will be accepted and the initial display will
appear again.
1. OK-button: You access the menu level;
the clock flashes.
2. Setting knob: Clockwise to
menu,
flashes.
3. OK-button: You accept the menu;
the day selection symbol
flashes.
4. Setting knob: Select the days, the working days,
the weekend or the week.
5. OK-button: You save the selection made;
heating period flashes.
6. Setting knob: Counterclockwise to
7. OK-button: Accept
;
comfort period 1 flashes.
7. OK-button: You accept comfort period 1;
start time of comfort period 1
flashes.
9. Setting knob: Set the start time of
comfort period 1.
10. OK-button: You save the input; end time of
comfort period 1 flashes.
11. Setting knob: Set the end time of
comfort period 1.
12. OK-button: You save the input; setpoint of
comfort period 1 flashes.
13. Setting knob: Set the setpoint of
comfort period 1.
14. OK-button: You save the input;
comfort period 2 flashes.
15. OK-button: You accept comfort period 2;
start time of comfort period 2
flashes.
16. Setting knob: Set the start time of
comfort period 2.
17. OK-button: You save the input; end time of
comfort period 2 flashes.
18. Setting knob: Set the end time of
comfort period 2.
19. OK-button: You save the input; setpoint of
comfort period 2 flashes.
20. Setting knob: Set the setpoint of
comfort period 2.
21. Press the ESC-button to return to the
comfort periods menu: Menu item
comfort periods
flashes.
22. Setting knob: To menu item
or
comfort periods
(Change not necessarily required; press the ESC-
button several times to leave the menu level in
several steps, thus returning to the initial display.)
Settings for automatic operation with 1 or 3 comfort periods
Adjustable in operating modes , , and
The procedure to be followed is the same as that for automatic operation with 2 comfort periods. The only
difference being that, in addition, a setpoint for comfort period 3 can be entered (standard setting 21 °C)
Absence / holidays
Adjustable in operating modes , , and
OK
OK
OK
OK
° C
ESC
ESC
If no button is pressed for 20 seconds, the setting
displayed will be accepted and the initial display
will appear again.
1. OK-button: You access the menu level;
the clock flashes.
2. Setting knob: To
, menu ; flashes.
3. OK-button: Accept
;
symbol
flashes.
4. Setting knob: Set the start (weekday) of your
absence.
5. OK-button: You save the input;
the number of days flash.
6. Setting knob: Set the duration of your absence;
number of days (max. 99 days)
7. OK-button: You save the input;
setpoint
flashes.
8. Setting knob: Set the temperature.
9. Press the ESC-button to return to the menu level;
the clock flashes.
(Change not necessarily required; press the
ESC-button again to return to the initial display)
Siemens / Building Technologies / HVAC Products B2218en 26.03.2007
Special day
Adjustable when this operating mode is selected
Special day with 24-hour mode and one comfort
period.
Start of comfort period, end of comfort period and
temperature setpoint can be set individually by
OK-button and setting knob.
Press the ESC-button to return to the initial display
Retrieving the default values
Press the button behind the small opening for at
least one second, thus resetting the user-specific
settings to their default values
(the heating engineer settings will remain
unchanged).
The clock starts at 12:00.
When making a reset, all display fields will light up.
Default values
Factory settings for heating
Operating mode
Start of continuous operation 00:00 00:00 00:00
End of continuous operation 24:00 24:00 24:00
Setpoint of comfort mode 19 °C
Setpoint of economy mode 16 °C
Setpoint frost protection 5 °C
Setpoint absence
12 °C
Operating mode
Selected periods
Start of period 1 07:00 06:00 06:00
End of period 1 23:00 08:00 08:00
Start of period 2 17:00 11:00
End of period 2 22:00 13:00
Start of period 3 17:00
End of period 3 22:00
Setpoint of period 1 19 °C 19 °C 19 °C
Setpoint of period 2
20 °C 20 °C
Setpoint of period 3
21 °C
Setpoint
see above
Default values
Factory settings for cooling
Operating mode
Setpoint 23 °C 23 °C 29 °C 35 °C
Setpoint
absence
30 °C
Changing the batteries
2 Alkaline-Batteries Type AA 1,5 V
When this symbol appears, the batteries must
be replaced within 3 months.
1. Remove controller from its base.
2. Open battery compartment at the rear and
replace the batteries.
3. Close battery compartment and replace the
controller.
Note:
When changing the batteries, the current data are
maintained for a maximum of one minute.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Siemens REA23.03RF bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Siemens REA23.03RF in de taal/talen: Engels als bijlage per email.

De handleiding is 0,36 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Siemens REA23.03RF

Siemens REA23.03RF Gebruiksaanwijzing - Deutsch - 2 pagina's

Siemens REA23.03RF Gebruiksaanwijzing - Français - 2 pagina's

Siemens REA23.03RF Installatiehandleiding - Alle talen - 40 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info