787872
10
Verklein
Vergroot
Pagina terug
1/92
Pagina verder
8
2. Clean lter
Use a vacuum cleaner or water to clean the lter. If the lter is very
dirty (such as grease), use warm water 40°C with neutral detergent
dissolved to clean and then put at shady place to dry it.
3. Install lter
After the lter is cleaned and dried, ensure that it is reinstalled
correctly.
NOTE
The lter should be cleaned about once every three months. If there is
a large amount of dust in the operation environment, you can increase
cleaning frequency.
Do not dry the lter with a direct heat source or hair drier. Otherwise, it
may be deformed or catch re.
Clean heat discharge pipe
Remove the heat discharge pipe from air conditioner, clean and dry it,
and then reinstall it. (For the method of installation, please refer to the
instruction for "Installing heat discharge pipe".)
Checking before use-season
Check whether air inlets and air outlets are blocked.
Check whether plug and socket are in good condition.
Check whether lter is clean.
Check whether batteries are installed in remote control.
Check whether joint, window bracket and heat discharge pipe are
installed rmly.
Check whether heat discharge pipe is damaged.
Checking after use-season
1. Disconnect power supply.
2. Clean lter and outer case.
3. Remove dust and sundries on the air conditioner.
4. Eliminate accumulated water in chassis (refer to the section of
"Removing collected water" for details).
5. Check whether window bracket is damaged or not.
6. If yes, please contact the dealer.
Long-time storage
If you don't use the air conditioner for a long time, please maintain it by
following steps for good performance:
Make sure that there is no accumulated water in chassis and the heat
discharge pipe is disassembled.
Pull out the plug and wrap the power cord.
Clean the air conditioner and pack it well to prevent dust.
Notice for recovery
Some of the packing items are recyclable materials. Please deal with
them through your local recycling provider.
If you want to dispose the air conditioner, please contact local authority
or consultant service center for the correct disposal method.
Troubleshooting
Before calling for service, please review the troubleshooting list below,
since the problem may not be a main unit malfunction.
Air conditioner can't operate
Cause / Action
Power failure? / Wait after power recovery.
Is plug loose? / Reinsert the plug.
Whether the air switch is tripped o or fuse is burnt? / Ask professional
person to replace air switch or fuse.
Is there malfunction for the circuit? / Ask professional person to replace
circuit.
Whether the unit is restarted up after stopping immediately? / Wait for 3
minutes, and then turn on the unit again.
Water owing noise
Cause / Action
Whether the unit is turned on or turned o just now? / There's owing
sound of refrigerant inside the air conditioner which is the normal
phenomenon.
Poor cooling
Cause / Action
Is the power too low? / Wait after voltage is resumed.
Whether the air lter is too dirty? / Clean the air lter.
Has the correct temperature been set? / Adjust the temperature.
Whether door and window are closed? / Close door and window.
Air conditioner can't receive signal from remote control or remote
control is not sensible.
Cause / Action
Whether the unit is interfered seriously (such as static pressure, unstable
voltage)? / Please pull out the plug. Insert the plug after about 3minutes,
and then turn on the unit.
Whether remote controller is within the receiving range? / The receiving
range of remote controller is 8meters . Do not exceed this range.
Whether it's blocked by obstacles? / Remove the obstacles.
Is sensitivity of remote controller low? / Check the batteries of remote
controller. If the power is low, please replace the batteries.
Whether there's uorescence lamp in the room? / Move the remote
controller close to air conditioner. Turn o the uorescence lamp and
try it again.
Cracking noise
Cause / Action
Whether the unit is turned on or turned o just now? / Heat expansion
or shrinkage for the panel due to change of temperature, which cause
friction sound.
There's abnormal sound during operation
Cause / Action
Whether the unit is interfered by thunder, radio, etc? / Disconnect power,
put through the power again, and then turn on the unit again.
Odors
Cause / Action
There's o-avour source in the room, such as furniture, cigarette etc. /
Eliminate the o-avour source. Clean the lter.
No air blown out from air conditioner
Cause / Action
Whether air outlet or air inlet is blocked? / Eliminate the obstacles.
The unit will stop blowing fan after reaching set temperature.
Set temperature can't be adjusted.
Cause / Action
Whether the unit operates under auto mode? / Temperature can't be
adjusted under auto mode.
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Sharp UL-C09EA-W bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Sharp UL-C09EA-W in de taal/talen: Duits, Engels, Frans, Italiaans, Spaans, Pools als bijlage per email.

De handleiding is 30.7 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info