753069
9
Verklein
Vergroot
Pagina terug
1/212
Pagina verder
Version 12/20 ID no. 1-026-966
EN
FR
IT
NL
SV
FI
INSTRUCTIONS FOR INSTALLATION AND USE
English
DE
Sauna control unit
Pro B2
PRO-B2
Table of Contents
1. About this instruction manual 4
2. Important information for your safety 5
2.1. Intended use 5
2.2. Safety information for the installer 6
2.3. Safety information for the user 7
3. Product description 8
3.1. Scope of delivery 8
3.2. Optional accessories 8
3.3. Product functions 8
3.4. Sensor operating modes 9
4. Installation 10
4.1. Installing the sauna control unit 10
4.2. Installing the heater sensor F1 with excess temperature fuse 12
4.3. Installing bench sensor F2 (optional) 13
5. Electrical connection 14
5.1. Connecting the power supply cable and heater cable 15
5.2. Connecting the light 15
5.3. Connecting the power booster (optional) 16
5.4. Connecting heater sensor F1 16
5.5. Installing bench sensor F2 (optional) 16
5.6. Connectingthesafetyshut-o󰀨 16
5.7. Remote start 17
5.8. Finishing installation 17
6. Performing tests 18
7. Connection diagram 20
EN
8. Starting-up 21
8.1. Setting the heating period limit 21
8.2. Activating/deactivating phase alignment 22
8.3. Activating/deactivating the single-sensor mode 22
8.4. Displaying the heater temperature in single-sensor mode 22
9. Operation 23
9.1. Operating elements 23
9.2. Switching on the light 23
9.3. Switching on the sauna control unit 24
9.4. Starting the sauna 24
9.5. Changing the preset temperature 24
9.6. Setting the preset time 25
9.7. Cancelling the preset time function 26
9.8. Activating standby for remote operation 26
9.9. Switchingo󰀨thesaunacontrolunit 26
10. Cleaning and maintenance 27
10.1. Cleaning 27
10.2. Maintenance 27
11. Disposal 27
12. Troubleshooting 28
12.1. Error messages 28
12.2. Fuses 29
13. Technical data 30
Instructions for installation and use p. 4/30
1. About this instruction manual
Read these instructions for installation and use carefully and keep them within
reach of the sauna control unit. This ensures that you can refer to information
regarding your safety and regarding operation at any time.
Symbols used for warning notices
In these instructions for installation and use, a warning notice located next to
an activity indicates that this activity poses a risk. Always observe the warning
notices. This prevents damage to property and injuries, which in the worst case
may be fatal.
The warning notices contain keywords, which have the following meanings:
DANGER!
Serious or fatal injury will occur if this warning notice is not observed.
WARNING!
Serious or fatal injury can occur if this warning notice is not observed.
CAUTION!
Minor injuries can occur if this warning notice is not observed.
ATTENTION!
This keyword is a warning that damage to property can occur.
Other symbols
This symbol indicates tips and useful information.
These installation and operating instructions can also be found in the
downloads section of our website: www.sentiotec.com/downloads.
EN
Instructions for installation and use p. 5/30
2. Important information for your safety
The sauna control unit Pro B2 has been produced in accordance
with the applicable safety regulations for technical units. However,
hazards may occur during use. Therefore adhere to the following
safetyinformationandthespecicwarningnoticesintheindividual
chapters. Also observe the safety information for the devices con-
nected.
2.1. Intended use
The sauna control unit Pro B2 is used exclusively for operating and
controlling the sauna functions in accordance with the technical data.
The sauna control unit Pro B2 may only be used for operating and
controllingasaunaheaterwhichhasbeencertiedassatisfying
the combustion test described in paragraph 19.101 of EN 60335-
2-53. If the heater does not meet this requirement, an appropriate
safetyprecautionmustbetaken(forexample:safetyshut-o󰀨,see
5.6 on page 16).
The sauna control unit Pro B2 may only be used for operating and
controlling 3 heating circuits with a maximum heating capacity
of 3.5 kW per heating circuit.
Any use exceeding this scope is considered improper use. Improper
use can result in damage to the product, in severe injuries or death.
Instructions for installation and use p. 6/30
2.2. Safety information for the installer
Installationmayonlybeperformedbyaqualiedelectricianor
similarlyqualiedperson.
Work on the sauna control unit may only be performed when the
power has been disconnected.
Anall-poledisconnectingdevicewithfullcut-o󰀨compliantwith
overvoltagecategoryIIImustbettedon-site.
The sauna control unit must be installed outside the sauna room
at a height of approx. 1.70 m or in accordance with the rec-
ommendation issued by the sauna manufacturer. The ambient
temperature must be within a range spanning -10 °C to +40 °C.
The heater sensor must be attached in a way that it is not af-
fectedbyaowofair.
The heater supply cable must have a minimum cross-section of
2.5 mm2 and be temperature resistant up to 150 °C.
Also comply with the regulations applicable at the installation
location.
For your own safety, consult your supplier in the event of prob-
lemsthatarenotexplainedinsu󰀩cientdetailintheinstallation
instructions.
EN
Instructions for installation and use p. 7/30
2.3. Safety information for the user
The sauna control unit must not be used by children under
8 years old.
The sauna control unit may only be used by children above 8 years
old, by persons with limited psychological, sensory or mental
capabilities or by persons with lack of experience/knowledge:
When they are supervised.
When they have been shown how to use the device safely
and are aware of the hazards that could occur.
Children must not play with the sauna control unit.
Children under 14 years of age may only clean the sauna control
unit if they are supervised.
Forhealthreasons,donotusethesaunawhenundertheinu-
ence of alcohol, medication or drugs.
Makesurethatnoammableobjectshavebeenplacedonthe
sauna heater before the sauna control unit is switched on.
Makesurethatnoammableobjectshavebeenplacedonthe
heater before activating the preset time function or the stand-by
mode for the remote start.
For your own safety, consult your supplier in the event of prob-
lemsthatarenotdescribedinsu󰀩cientdetailintheoperating
instructions.
Instructions for installation and use p. 8/30
3. Product description
3.1. Scope of delivery
Sauna control unit
Heater sensor with integrated excess temperature fuse
Sensor wires
Installation material
3.2. Optional accessories
Bench sensor (item number: O-F2)
Power booster (item number: O-S2-18 / O-S2-30)
Safetyshut-o󰀨(itemnumber:SFE-xxxxx)
pronet web server (item number: PRO-NET)
3.3. Product functions
The sauna control unit Pro B2 features the following functions:
Regulation of sauna heaters with a heating output of up to 10.5 kW in the
temperature range spanning 30 °C to 110 °C.
A power booster allows the maximum contact rating to be increased from
10.5 kW to 18 kW or 30 kW.
Remote start function
Preset time function (up to 24 hours)
Automatic heating period limiter
The sauna control unit shuts down automatically after the maximum heating
period for safety reasons. The maximum heating period can be set to 6 h,
12 h, 18 h or 24 h.
Excess temperature fuse
The excess temperature fuse is installed in the housing for the heater sen-
sor. Should the sauna heater continue heating after reaching the preferred
temperature due to a defect, the excess temperature fuse switches the sauna
heatero󰀨atatemperatureofapprox.139°C.
EN
Instructions for installation and use p. 9/30
3.4. Sensor operating modes
The sauna control unit can be operated with one or two temperature sensors.
Single-sensor mode (F1)
Single-sensormodemustbeactivatedwhenstartingupthesaunafortherst
time (see 8.3. Activating/deactivating the single-sensor mode on page 22).
In single-sensor mode, the sauna control unit is operated with the heater sensor
with an excess temperature fuse (F1) only. In single-sensor mode, the sauna
control unit only displays the set temperature. The actual temperature is not dis-
played. Should the sauna control unit display the temperature above the heater
(F1) as an actual temperature in single-sensor mode, it must be activated when
startingupforthersttime(see8.4. Displaying the heater temperature in
single-sensor mode on page 22)
Two-sensor mode with bench sensor (F2)
In two-sensor mode with bench sensor, a second temperature sensor (bench
sensor) is installed above the rear sauna bench. The sauna control unit displays
the temperature measured by the bench sensor as the actual temperature.
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Sentiotec Pro B2 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Sentiotec Pro B2 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Zweeds, Fins als bijlage per email.

De handleiding is 9,08 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info