Error messages
Error messages
on the display
Meaning Solution
AS Humidity sensor
error
Disconnect the power plug from the
power socket and reconnect it.
If the problem persists, please contact an
authorised service centre.
ES Vaporizer heat
sensor error
Disconnect the power plug from the
power socket and reconnect it.
If the problem persists, please contact an
authorised service centre.
P2 The condensate
tank A3 is full or
incorrectly installed.
Empty out the condensate tank A3 or
install it correctly.
Eb The condensate tank
A3 is removed or
incorrectly installed.
Insert the condensate tank A3 into the
appliance.
Servicing instructions
1.1 Area check
Before starting work on asystem containing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimised. When repairing acooling
system, the following measures must be adhered to prior to performing any work.
1.2. Work procedure
Work must be performed following acontrolled procedure so that the risk of flammable
gases or fumes being present during this time is minimised.
1.3 General work area
The whole maintenance crew and other personnel at the site must be informed about
the nature of the works being performed. Work in tight areas must be prevented. The
area around the work site must be divided into sections. It must be ensured that the
conditions inside the area are safe by means of inspections of flammable materials.
1.4 Check for presence of arefrigerant
The area must be checked using an appropriate detector for the presence of refrigerant
before and during work to ensure that technicians are aware of apotentially flammable
atmosphere. It must be ensured that the device used for the detection of leaks is
suitable for use on flammable refrigerants, i.e. non-sparking, appropriately sealed or
intrinsically safe.
1.5 Presence of afire extinguisher
In the event that any work is performed on the cooling device or associated parts under
heat, then asuitable fire extinguisher must be on hand. In the vicinity of the filling area,
there must be apowder or CO2 fire extinguisher.
1.6 No ignition sources
No person performing work related to the cooling system that encompasses the
uncovering of any pipes that contain or have contained flammable gasses may use any
ignition sources in amanner that could lead to afire or explosion hazard. All possible
ignition sources, including the smoking of cigarettes should be kept at asufficient
distance from the installation, repair, removal or disposal location, during which
flammable refrigerant could potentially be released into the surrounding environment.
Prior to starting work, the area around the appliance must be checked to ensure that
there are no fire hazards or ignition risks present. A"smoking forbidden" sign must
be installed.
1.7 Ventilated area
It must be ensured that the area is ventilated or appropriately ventilated prior to
penetrating the system or performing any work under heat. The intensity of ventilation
must continue for the time that works are performed. Ventilation should safely dissipate
any released refrigerant and draw it out into the atmosphere as apriority.
1.8 Cooling system checks
In places where electrical components are replaced, these components must be suitable
for this purpose and conform to correct specifications. The manufacturer'sinstructions
for maintenance and service must always be followed. If any doubts arise, it is necessary
to request help from the manufacturer'stechnical department.
On installations containing flammable refrigerants, it is necessary to perform the
following checks:
the amount of refrigerant corresponds to the size of the room in which components
containing refrigerant are installed;
ventilation systems and outlets are in full working order and are not clogged;
if any indirect cooling circuit is used, the second circuit must be checked for the
presence of refrigerant;
the markings on the appliance must remain constantly visible and legible, and marking
and signs that are illegible must be repaired;
The cooling pipes and components are installed in locations where it is not probable
that they will be exposed to any substances that could corrode the parts containing
refrigerant, unless these components are built using materials that are inherently
resistant to corrosion or are appropriately protected against corrosion.
1.9 Electrical device check
The repair and maintenance of electrical components must include safety checks and
inspections of components.
In the event of amalfunction that could affect safety, no electrical power may be
connected to the circuit until the malfunction is satisfactorily resolved. In the event
that the malfunction cannot be immediately repaired but it is necessary to continue
running the appliance, an appropriate temporary solution must be used. The owner of
the appliance must be informed in such away that all parties know about it.
The initial safety check must ensure:
that capacitors are discharged: this must be performed in asafe way to prevent the
possibility of sparking;
that no electrical components or wiring is uncovered during the process of filling,
draining or cleaning the system;
that the grounding is not interrupted.
2. Repair of sealed components
When repairing sealed components, all the electrical power supply must be disconnected
from the appliance on which work is being performed before sealed lids, etc. are removed.
When it is absolutely necessary to have live power supply going into the appliance while
servicing the appliance, it is necessary to install apermanent device in the most critical
point to detect leakage so that adangerous situation is averted.
Special attention must be paid to ensuring that as aresult of the work performed on
electrical components the cover is not changed to the extent of affecting the level of
protection. This must also include damage to cables, excessive number of connections
and terminals not performed according to original specifications, damaged gaskets,
incorrect configuration of plugs, etc.
It is necessary to ensure that the appliance is mounted safely.
It is necessary to ensure that gaskets or sealing materials are not damaged in such away
that they no longer serve to prevent the entry of aflammable atmosphere. Spare parts
must conform to the manufacturer'sspecifications.
Note:
The use of silicone gaskets and seals may suppress the efficiency of certain
type of leak detection devices. Intrinsically safe components do not need to
be disconnected prior to being worked on.
3. Repairs of intrinsically safe components
No permanently inductive or capacitative load may be placed on the circuit without it
being ensured that thereby the permitted voltage and current for the used appliance
is not exceeded.
Intrinsically safe components are the only type on which it is possible to work in
aflammable environment even while under live current. Testing equipment must have
correct specifications.
Parts are replaced using only parts specified by the manufacturer. Different parts could
result in ignition of refrigerant upon leakage into the environment.
4. Cabling
Check that cabling is not exposed to wear and tear, corrosion, excessive pressure,
vibrations, sharp edges or any other negative environmental effects. This check must
also take into consideration the effects of ageing and permanent vibrations from sources
such as compressors or fans.
5. Detection of flammable refrigerants
Under no circumstances may potential sources of ignition be used for locating or
detecting refrigerant leaks.
Ahalogen burner (or any other type of detector utilising an open flame) must not be used.
6. Leak detection methods
The following leak detection methods are considered acceptable for systems containing
flammable refrigerants.
For the detection of flammable refrigerants, electronic leak detectors must be used,
however their sensitivity may not be appropriate or they may require recalibration.
(Detection equipment must be calibrated in an area without any refrigerant present).
It is important to ensure that the detector is not apotential ignition source and that
it is suitable for the used refrigerant. The leak detector must be set to apercentage of
LFL refrigerant and must be calibrated for the used refrigerant and the respective gas
percentage is confirmed (maximum 25%).
Leak detection liquids are suitable for use on most refrigerants, however, detergents
containing chlorine must be excluded since chlorine may react with the refrigerant
and corrode copper pipes.
In the event of asuspected leak, all open flames must be removed/extinguished.
In the event that the refrigerant leak is found and requires hard soldering, then all the
refrigerant must be drained from the system or separated (by closing avalve) in apart of
the system distant from the leak. The system must then be cleaned out using oxygen-free
nitrogen (OFN) both before as well as after the hard soldering process.
7. Collection and pump discharge
In the event that the cooling circuit is breached due to repairs – or for any other reason
conventional procedures must be followed. It is, however, important to adhere to the
best method due to flammability. It is necessary to adhere to the following procedure:
remove the refrigerant;
clean out the circuit using inert gas;
pump out;
again clean out using inert gas;
open the circuit by cutting or hard soldering.
The contents of the circuit must be collected into correct collection cylinders. The system
must be "flooded" with OFN (oxygen-free nitrogen) for the unit to remain safe. It may
be necessary to repeat the procedure several times. For this task, neither compressed
air nor oxygen may be used.
Flooding may be achieved by disrupting the vacuum in the system with the use of
OFN, and by continued filling until the operating pressure is achieved, then venting
into the atmosphere and finally lowering to avacuum. This process must be repeated
if refrigerant still remains in the system. When the last OFN cartridge is used, the system
must be ventilated to atmospheric pressure to enable work to be performed. This activity
is absolutely necessary if hard soldering is to be performed on the pipes.
It is necessary to ensure that the vacuum pump outlets are not nearby to any ignition
source, and ventilation must be provided.
8. Filling procedure
Apart from conventional filling procedures, also the following requirements must be
adhered to.
It is necessary to ensure that no contamination by various refrigerants occurs when
the filling device is used. Hoses or pipes must be as short as possible to minimise the
amount of refrigerant contained inside of them.
Cylinders must be held vertically.
It is important to ensure that the cooling system is grounded prior to being filled with
refrigerant.
When filling is complete, the system must be marked with alabel (if it does not have
one already).
It is necessary to pay extreme care to ensure that the cooling system is not overfilled.
12

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Sencor SDH 3020 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Sencor SDH 3020 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,2 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info