Cleaning the condensate tank
Empty out the condensate tank A6 whenever you finish using the appliance and
wipe it using awiping cloth.
To prevent undesirable bacteria, micro-organism or moulds from multiplying inside
the tank, clean it out at least once per month using acloth dampened in lukewarm
water with the addition of neutral detergent. Then rinse it out thoroughly using
clean water, wipe it dry and insert it back into the appliance.
Do not wash the tank in adishwasher.
Cleaning the air lter
Check and clean the air inlet grille with filter A8 at least once every two weeks or, if
necessary, more frequently when the appliance is used every day.
Release the grille with filter by applying slight pressure to the tab on the bottom
edge and remove it carefully. Wash the grille with filter in warm water with a small
amount of kitchen detergent. Then thoroughly rinse it under running water and
allow it to dry naturally. Install the grille with filter back in its place. However, first
make sure that it is completely dry.
Warning:
Do not use the appliance without the grille with filter being
properly installed. Do not wash the grille with filter in a
dishwasher.
Cleaning the outer cover and air outlet grilles
To clean the air outlet grille A2, the air inlet grille A8 and the outer cover, use
awiping cloth lightly dampened in lukewarm water with asmall addition of neutral
detergent. Make sure that water does not enter into the vents. In the event that the
grilles are only dusty, avacuum cleaner may be used to clean them.
Storage
When not using the appliance for an extended period of time, disconnect the power
plug from the power socket and clean it according to the instructions provided
above.
Clean the condensate tank A6 only 24 hours after turning the appliance off since
even during this time asmall amount of condensate may accumulate.
Secure the power cord using the strap A10.
Store the appliance in a dry, clean and well-ventilated location not exposed to
extreme temperatures and out of children‘sreach.
TROUBLESHOOTING
Problem Solution
The dehumidifier cannot be
turned on.
Check that the power cord plug is correctly
connected to apower socket.
Check that fuses are in order.
The dehumidifier reached the set humidity level or
the condensate tank A6 is full.
The condensate tank A6 is not correctly installed.
The dehumidifier is not
removing humidity from the
room.
The dehumidifier has only been running for
ashort time, please wait afew more moments.
Make sure that there are no curtains, roller blinds
or furniture in front of the dehumidifier.
The humidity setting is insufficient.
Check that the doors, windows and other
openings in the room are properly closed.
The temperature in the room is too low
(below5°C).
There is an oil heater or other appliance located in
the room that may be creating humidity.
The dehumidifier is too noisy
while running.
The air filter is clogged.
The dehumidifier is tilted.
The floor is not level.
Frost is forming inside the
appliance.
The dehumidifier is equipped with an automatic
defrost function, which is activated when frost
starts to form.
There is water on the floor. Check the hose for damage and that it is correctly
attached.
Disconnect the hose and use the condensate
tank A6 to drain the condensate. Close outlet A9
using aplug.
Button B4 is flashing. The humidity / temperature sensor is damaged.
Contact an authorised service centre.
Error messages
Error messages
on the display
Meaning Solution
AS Humidity sensor error Disconnect the power plug from the
power socket and reconnect it.
If the problem persists, please contact
an authorised service centre.
ES Vaporizer heat sensor
error
Disconnect the power plug from the
power socket and reconnect it.
If the problem persists, please contact
an authorised service centre.
P2 The condensate tank
A6 is full or incorrectly
installed.
Empty out the condensate tank A6 or
install it correctly.
1. Servicing instructions
1.1 Area check
Before starting work on asystem containing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimized. When repairing acooling
system, the following measures must be adhered to prior to performing any work.
1.2. Work procedure
Work must be performed following a controlled procedure so that the risk of
flammable gases or fumes being present during this time is minimised.
1.3 General work area
The whole maintenance crew and other personnel at the site must be informed about
the nature of the works being performed. Work in tight areas must be prevented. The
area around the work site must be divided into sections. It must be ensured that the
conditions inside the area are safe by means of inspections of flammable materials.
1.4 Check for presence of arefrigerant
The area must be checked using an appropriate detector for the presence of refrigerant
before and during work to ensure that technicians are aware of apotentially flammable
atmosphere. It must be ensured that the device used for the detection of leaks is
suitable for use on flammable refrigerants, i.e. non-sparking, appropriately sealed or
intrinsically safe.
1.5 Presence of afire extinguisher
In the event that any work is performed on the cooling device or associated parts
under heat, then asuitable fire extinguisher must be on hand. In the vicinity of the
filling area, there must be apowder or CO2 fire extinguisher.
1.6 No ignition sources
No person performing work related to the cooling system that encompasses the
uncovering of any pipes that contain or have contained flammable gasses may
use any ignition sources in amanner that could lead to a fire or explosion hazard.
All possible ignition sources, including the smoking of cigarettes should be kept at
asufficient distance from the installation, repair, removal or disposal location, during
which flammable refrigerant could potentially be released into the surrounding
environment. Prior to starting work, the area around the appliance must be checked
to ensure that there are no fire hazards or ignition risks present. A„smoking forbidden“
sign must be installed.
1.7 Ventilated area
It must be ensured that the area is ventilated or appropriately ventilated prior to
penetrating the system or performing any work under heat. The intensity of ventilation
must continue for the time that works are performed. Ventilation should safely
dissipate any released refrigerant and draw it out into the atmosphere as apriority.
1.8 Cooling system checks
In places where electrical components are replaced, these components must be suitable
for this purpose and conform to correct specifications. The manufacturer‘sinstructions
for maintenance and service must always be followed. If any doubts arise, it is
necessary to request help from the manufacturer‘stechnical department.
On installations containing flammable refrigerants, it is necessary to perform the
following checks:
the amount of refrigerant corresponds to the size of the room in which components
containing refrigerant are installed;
ventilation systems and outlets are in full working order and are not clogged;
if any indirect cooling circuit is used, the second circuit must be checked for the
presence of refrigerant;
the markings on the appliance must remain constantly visible and legible, and
marking and signs that are illegible must be repaired;
The cooling pipes and components are installed in locations where it is not probable
that they will be exposed to any substances that could corrode the parts containing
refrigerant, unless these components are built using materials that are inherently
resistant to corrosion or are appropriately protected against corrosion.
1.9 Electrical device check
The repair and maintenance of electrical components must include safety checks and
inspections of components.
In the event of a malfunction that could affect safety, no electrical power may be
connected to the circuit until the malfunction is satisfactorily resolved. In the event
that the malfunction cannot be immediately repaired but it is necessary to continue
running the appliance, an appropriate temporary solution must be used. The owner of
the appliance must be informed in such away that all parties know about it.
The initial safety check must ensure:
that capacitors are discharged: this must be performed in asafe way to prevent the
possibility of sparking;
that no electrical components or wiring is uncovered during the process of filling,
draining or cleaning the system;
that the grounding is not interrupted.
2. Repair of sealed components
When repairing sealed components, all the electrical power supply must be disconnected
from the appliance on which work is being performed before sealed lids, etc. are removed.
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Sencor SDH 1020 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Sencor SDH 1020 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,6 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info