757456
15
Verklein
Vergroot
Pagina terug
1/15
Pagina verder
28
English
29
English
Problem Possible cause Solution
The watch calculates decompression
diving even after a dive.
The diver ascended defying the
decompression stop violation warning.
When the surface interval time is less than 5 minutes, making a
decompression stop as indicated by the watch will return the
display for no-decompression diving.
**The log data stored in the dive log function will not be erased when the battery is replaced with a new one. If any malfunction is found during
checking, however, the stored log data may be erased when the watch is repaired. It is recommended that the log data in memory be noted down
in your log book before requesting a battery change.
SPECIFICATIONS
1 Frequency of crystal oscillator ... 32,768 Hz (Hz = Hertz … Cycles per
second)
2 Loss/gain (Monthly rate) ............ Less than 15 seconds at normal
temperature range (5° C ~ 35° C)
(41° F ~ 95° F)
3
Operational temperature range
... –5° C ~ +40° C (23° F ~ 104° F) for
depth measurement, alarm sound,
display and illuminating light
–10° C ~ +60° C (14° F ~ 140° F) for
timing function
* In very low temperatures, the
display light may dim, and the
change of digits may become slow.
4 Display system
TIME/CALENDAR display ..... Hour, minutes, seconds, month,
date, and day [surface interval time
and desaturation time]
REGULAR ALARM display .... Regular alarm time (hour and
minutes)
FO2 (NITROX) display ............ FO2 setting
DIVE PLAN display ............... Depth rank and no-decompression
limit [surface interval time and
desaturation time]
DIVE LOG display ................. Log No., date of dive, dive time,
entry/exit time, FO2 setting, average
depth, maximum depth, water
temperature at maximum depth,
and residual nitrogen/oxygen at end
of dive
HOUR CORRECTION display ..
Hour and minutes
Dive mode ............................ No-decompression limit, dive time,
current depth, maximum depth,
water temperature, residual
nitrogen, FO2 setting, current time,
PO2 value and residual oxygen
5 Display medium ......................... Nematic Liquid Crystal, FEM (Field
Effect Mode)
6 Battery ....................................... SEIKO CR2032, 1 piece
7 Battery life ................................. Approx. 3 years
8 Illuminating light ......................... Electroluminescent panel
9 Sensor accuracy ......................... Depth: Within ±3% of the displayed
value + 0.5 m (2 ft)
Water temperature: ±2° C (4° F)
10
IC (Integrated Circuit) ................. C-MOS-LSI, 2 pieces
Non-volatile memory, 1 piece
* The specifications are subject to change without prior notice for product improvement.
TROUBLESHOOTING
Problem Possible cause Solution
The watch gains/loses occasionally. The accuracy will be corrected when the watch returns to normal
temperature. Set the time before using the watch. It is so adjusted
that it operates with stable accuracy when used on the wrist within
a temperature range between 5° C and 35° C (41° F and 95° F).
The watch was left in low or high
temperatures.
The display became blank. The battery has run down. Take the watch to the retailer from whom it was purchased
immediately for battery replacement.
**
The battery life indicator is shown.
The battery life indicator is flashing.
The battery is nearing its end.
A blur inside the glass persists. Consult the retailer from whom it was purchased.
The gasket is deteriorated, and water
got inside the watch.
Unless you are at an altitude over 6,000
m (19,700 ft), the pressure sensor is out
of order.
Three altitude rank indicator bars are
flashing.
The number of residual nitrogen
indicator bars on the display
increased while on the surface.
You moved to a higher altitude across
the altitude ranks.
The watch senses the atmospheric pressure change and re-
calculates residual nitrogen. The obtained residual nitrogen will be
taken into consideration in calculations in the dive plan function.
The atmospheric pressure inside
airplanes corresponds to altitude rank
“2”, and the watch has re-calculated
the altitude.
The number of residual nitrogen
indicator bars on the display
increased during flight.
Water remains on the auto switch.
The display will not return to the
TIME/CALENDAR after diving.
Wipe the auto switch with a dry cloth.
Water remains on the auto switch, or
the auto switch was turned on during
flight and the airplane landed.
The dive function was shown while
on the surface, and a depth of more
than 1.5 m (5 ft) was displayed.
Make sure that the auto switch is always clean and dry. In a place
such as inside an airplane where the atmospheric pressure changes
sharply, take utmost care not to leave the auto switch wet.
A dive beyond the specified limit was
made within the past 48 hours.
The dive function will not start. Do not use the watch for diving for 48 hours.
The battery life indicator is lighting up or
flashing.
Take the watch to the retailer from whom it was purchased
immediately for battery replacement.
Three altitude rank indicator bars are
flashing.
The watch cannot be used for diving at an altitude over 6,000 m
(19,700 ft). Unless you are at an altitude over 6,000 m, the
pressure sensor is out of order. Consult the retailer from whom
it was purchased.
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Seiko DH33 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Seiko DH33 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,84 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Seiko DH33

Seiko DH33 Gebruiksaanwijzing - Deutsch - 14 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info