GB
15
Connecting the motor
For the HLS 998 model
! The assembly comes without a motor and therefore
must be connected to a motor (accessory purchased
separately) located outside of the appliance itself. The
electrical connection must be made using the
appropriate terminals.
! Only use 4-speed Scholtès motor.
Connecting the exhaust duct to the
external motor
The external motor unit must be installed in a suitable
location in compliance with current safety regulations.
The motor and the assembly must be connected using
an exhaust duct with the correct diameter (Ø 150 mm).
To insure th a t th e ho o d op e r a t e s efficiently, ke e p in
mind that ventilation becomes less efficient the longer
the exhaust duct which connects the assembly to the
motor.
The exhaust duct must not exceed 7 meters in length.
The materials (the duct and the clamp) must be
provided by the installer.
Electrical connection for external motor
• Check the position of electrical connection
compartment B situated over the hood.
• Remove the screws to open the B compartment
cover.
• Open the cable block by removing the L screws.
• To connect the h o o d to t h e motor u s e an
harmonized omnipolar interconnection cable (HAR)
type H05 VV-F (6 x 0,75mm
2
).
• Connect the terminals of the cable coming from the
motor to the terminal board situated on the B
compartment on the hood.
• Close cable block L again (this should act to block
both the cable coming from the hood and the
electric connecting cable of the external motor).
• Close cover B.
• Carry out the electrical connection of the hood to
the power.
).