www.scheppach.com service@scheppach.com +(49)-08223-4002-99 +(49)-08223-4002-58
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
19 І GB
• As the user, you are required to ensure, in consul-
tation with your electric power company if neces-
sary, that the connection point at which you wish
to operate the product meets the specied re-
quirements.
Operation
The equipment consists of an assembly with a pump,
which is encased in a shock absorbing housing. The
equipment comes with a lance and a non-slip gun (for
an optimal working position), whose shape and con-
guration comply with the applicable regulations.
Commissioning:
Once you have completely assembled the high-pres-
sure cleaner and all connections have been made,
proceed as follows:
Turn on the water supply. Unlock the pistol (17) via
the locking switch (C). Pull back the trigger lever (D)
so that the air in the device can discharge. (Fig. 4)
Switch on the device by setting the on/off switch (4)
to “ON”. Next, press the trigger lever (D). (Fig. 1/4)
To switch off, release the trigger lever (D), and the
device switches to stand-by. The high-pressure
cleaner starts again when you press the trigger le-
ver (D). (Fig. 4)
To switch off the high-pressure cleaner completely,
set the on/off switch (4) to “OFF”. (Fig. 1)
Cleaner container (9)
Fill the cleaner container with the corresponding
cleaner. The cleaner is dosed automatically in low-
pressure operation.
Cleaning agents are only suctioned if the rotating
brush (21) or cleaning brush (22) are tted.
Using the attachments (Fig. 1):
90° turbo nozzle (13): For car underbody and gut-
ter cleaning.
Kärcher adapter (14): Use this adapter to attach
Kärcher brand accessories.
Terrace cleaner (15): For cleaning oor and wall sur-
faces.
Pipe cleaning hose (16): For cleaning pipes, drains,
toilets and loosening blockages
Turbo nozzle (19): For eliminating stubborn dirt.
Nozzle (20): For coarse cleaning work.
Rotating brush (21): For surface cleaning
Cleaning brush (22): For surface cleaning.
Suction from open tanks/containers and natural
bodies of water
Use a special self-suction accessory (not included
with delivery / available from dealer)
With this accessory, the high-pressure cleaner can
take in water 0.5 m above the water level. This can
last about 25 to 50 seconds.
Immerse the accessory’s hose completely under wa-
ter to drive the air out of the hose.
Connect the accessory’s hose to the high-pressure
cleaner, and make sure that the suction strainer re-
mains under water.
Let the high-pressure cleaner run with the spray gun
removed until the water ows evenly out of the high-
pressure hose.
If no water comes out after 25 to 50 seconds, switch
off and check all connections.
Once the water is owing, turn off the high-pressure
cleaner and connect the spray gun and spray lance
to start work.
High-pressure hose connection (Fig. 3/4)
Connect the high-pressure hose (3) to the connec-
tion for the high-pressure hose (7). Remove the pro-
tective cover rst.
Insert the other end of the high-pressure hose (3)
into the pistol connection (17).
To remove the high-pressure hose (3), press the but-
ton Taste (A) and pull it out.
Connecting the attachments (Fig. 5)
To mount attachments 14, 16, 18, 22 and 21 press
them into the pistol (17) and turn them until the lock.
To mount attachments 13,15, 19 and 20, insert these
into the attachment (18) and turn them until they lock.
Electrical connections
• Before you connect the appliance to the mains sup-
ply make sure that the data on the rating plate are
identical to the mains data.
• If you use any extension cables, make sure that
they are suitable for outdoor use and have large
enough wires:
1-10m: 1,5mm2
10-30m: 2,5mm2
• Plug the mains plug on the power cable into the
mains socket outlet.
• The product meets the requirements of EN 61000-
3-11 and is subject to special connection condi-
tions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavorable conditions in the power sup-
ply the product can cause the voltage to uctuate
temporarily.
• The product is exclusively intended for use at con-
nection points that have a continuous current-car-
rying capacity of at least 100 Amper phase.