FEATURES
This air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided
below; refer to these descriptions when using the air conditioner.
Microprocessor Controlled Operation
The interior compartment of the remote control unit
contains several features to facilitate automatic
operation, easy logically displayed for easy use.
Simple One-touch Wireless Remote Control
The remote control unit has several features to facilitate
automatic operation.
24-Hour ON or OFF Timer
This timer can be set to automatically turn the unit on or
off at any time within a 24 hour period.
1-Hour OFF Timer
This timer can be set to automatically turn off the unit at
any time after one hour.
•Night Setback
Pressing this button changes the setting of the room
temperature thermostat, allowing you to set the
temperature at whatever level that you find comfortable.
Automatic and 3-step Fan Speed
Auto/High/Medium/Low
Air Sweep Control
This function moves a flap up and down in the air outlet,
directing air in a sweeping motion around the room and
providing comfort in every corner.
Auto. Flap Control
This automatically sets the flap to the optimum position
during heating, cooling, and drying operation.
Automatic Switching between Cooling and Heating
This unit automatically switches between cooling
operation and heating operation according to the
difference between the room temperature and the
temperature setting.
Hot Start Heating System
Right from the start, the air is warm and comfortable.
This system prevents any cold blasts at the beginning
while the heat pump is warming up, or even defrosting.
Automatic Restart Function for Power Failure
Even when power failure occurs, preset programmed
operation can be reactivated once power resumes.
High Power Operation
If not in Auto Operation, the unit operates at maximum
output for 30 minutes, regardless of the desired
temperature.
The fan speed is 1 step above “High”.
Quiet Operation
The fan rotates slower than the fan speed setting to
provide a quieter operating sound.
LED Clean Operation
During operation, the UV anti-bacteria unit is activated
for one hour and cleans the air blown from the air
conditioner.
Anti-Mold Filter
This unit is equipped with an anti-mold filter that inhibits
the growth of mold and bacteria.
Air Clean Filter
An air filter that eliminates unpleasant odors and cleans
the air is available.
Purchase a replacement filter at your local dealer.
(model STK-FDXB)
CONTENTS
Page
FEATURES......................................................................................................................................... 2
PRODUCT INFORMATION ................................................................................................................ 3
ALERT SYMBOLS.............................................................................................................................. 3
INSTALLATION LOCATION................................................................................................................ 3
ELECTRICAL REQUIREMENTS........................................................................................................3
SAFETY INSTRUCTIONS..................................................................................................................3
NAMES OF PARTS.............................................................................................................................4
USING THE REMOTE CONTROL UNIT............................................................................................ 8
OPERATION WITH THE REMOTE CONTROL UNIT ........................................................................9
1. Automatic Operation............................................................................................................9
2. Manual Operation................................................................................................................9
3. Adjusting the Fan Speed ................................................................................................... 10
4. Fan Only............................................................................................................................ 10
5. Night Setback Mode ..........................................................................................................10
6. QUIET Mode ..................................................................................................................... 10
7. HIGH POWER Mode......................................................................................................... 11
8. LED CLEAN Mode ............................................................................................................11
SPECIAL REMARKS........................................................................................................................ 11
SETTING THE TIMER...................................................................................................................... 12
USING THE 1-HOUR OFF TIMER................................................................................................... 13
TIPS FOR ENERGY SAVING........................................................................................................... 13
ADJUSTING THE AIRFLOW DIRECTION .......................................................................................13
OPERATION WITHOUT THE REMOTE CONTROL UNIT............................................................... 14
CARE AND CLEANING....................................................................................................................14
TROUBLESHOOTING...................................................................................................................... 15
OPERATING RANGE .......................................................................................................................15
OI-002-2-EG
2column_01_SAP-KRV96EH_EN.fm Page 2 Wednesday, July 18, 2007 5:32 PM
51

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Sanyo-SAP-KRV96EH

Zoeken resetten

  • In verband met de aangifte stadsbelasting op "drijfkracht" wil ik mijn airco-toestellen doorgeven .
    Het betreft 4 binnenposten van een SANYO SAP-KRV96EH : hier staat iets op van Cooling 2,5 kW en Heating 3,3 kW . Dan heb ik ook nog 1 buitenpost waar iets op staat van Cooling 8 kW en Heating 9,4 kW . Bovenop dit ticket van mijn buitenpost staat nog iets van "Assorbimento max/max electric input 4000 W .. 17,0 A ... Buitenpost is ook van Sanyo Gesteld op 10-5-2020 om 18:53

    Reageer op deze vraag Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Sanyo SAP-KRV96EH bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Sanyo SAP-KRV96EH in de taal/talen: Engels als bijlage per email.

De handleiding is 1,69 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info