1. OPERATING RANGE
Maximum
Minimum
Maximum
Minimum
32 °C D.B. / 23 °C W.B.
19 °C D.B. / 14 °C W.B.
27 °C D.B.
16 °C D.B.
Temperature Indoor Air Intake Temp.
43 °C D.B.
–
5 °C D.B.
24 °C D.B. / 18 °C W.B.
–
D.B. /
–
15 °C W.B.
(*1)
Outdoor Air Intake Temp.
Cooling
Heating
(1) Outdoor Unit : SAP-CMRV1426EH, SAP-CMRV1926EH, SAP-CMRV1936EH
SAP-CMRV2446EH, SAP-CMRV3146EH
Indoor Unit : SAP-KMRV76EH, SAP-KMRV96EH, SAP-KMRV126EH
SAP-KRV186EH, SAP-KRV246EH
(*1) 0 °C D.B. : When combined with SAP-KRV186EH or SAP-KRV246EH
Maximum
Minimum
Maximum
Minimum
32 °C D.B. / 23 °C W.B.
19 °C D.B. / 14 °C W.B.
27 °C D.B.
16 °C D.B.
Temperature Indoor Air Intake Temp.
43 °C D.B.
–
10 °C D.B.
24 °C D.B. / 18 °C W.B.
–
D.B. /
–
15 °C W.B.
Outdoor Air Intake Temp.
Cooling
Heating
(2) Outdoor Unit : SAP-CMRV3656EH
Indoor Unit : SAP-KMRV76EH, SAP-KMRV96EH, SAP-KMRV126EH
SAP-KRV186EH, SAP-KRV246EH