COMMISSIONING
1- Once the hydraulic and electrical connections have been
made, check that the connections are water-tight by
allowing water to flow through each entry point used. Make
sure the unit is operating correctly by carrying out at least
2 test pumping cycles with water.
10
MAINTENANCE
It is necessary to make a visual inspection once a month to
check that the collection station is operating correctly, and the
station must be inspected regulary (once a year) by qualified
personnel.
If the power cable of the unit has been damaged, it must be
replaced by the manufacturer or an authorized after-sales
services agent.
12
GUARANTEE
SANICOM
®
2 is guaranteed for two years for parts and labour
provided it is both installed and used in accordance with the
current instructions.
13
USE
1- SANICOM
®
2 is designed to evacuate effluent from small
private or commercial units. Any other application of the
apparatus may render the guarantee void. Never use it for
paper towels, condoms or sanitary items, oils, solvents,
waste products, acids, bases, other liquids that could cause
an explosion, corrosive products, etc.
2- WARNING: In the event of a power failure, turn off
all water flowing into appliances connected
to SANICOM
®
2.
3- Do not install or use the unit in an area presenting risks of
explosion.
11
STANDARDS
This piece of equipment complies with the EN 12050-2
standard (Lift station for effluents not containing faecal matter)
and the directives and European standards on electric safety
and electromagnetic compatibility.
The installation and use of this unit must comply with
European installation standards EN12056 and with local
requirements.
9
ALARM
Please note that the alarm module runs on 220V. Attach the module
to the wall before connecting the device to the power supply. If the
water level inside the device is abnormally high: the red LED lights
up + the buzzer sounds. If the problem stops, the LED and the buz-
zer are deactivated.