4 in 1 Digital Thermostat Control
Models: VS10W and VS10B
INSTALLER / USER MANUAL
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:48
02 VS10W and VS10B Installer Manual
Contents
1 x Installer / User manual VS10W VS10BFixing screws
Contents
Box contents
Introduction
Product Compliance
System options overview
Installation
Parameter Settings
Error Codes
User Guide
Installers notes
Warranty
Box Contents
Icons used in this manual:
Safety
Important info
Your benet
For latest PDF installation guide please
go to www.salus-controls.com
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:48
Product Compliance & Safety Information
INTRODUCTION
Thank you for purchasing
the SALUS 4 in 1 digital room thermostat
VS10. To maximise the features the
unit, it should be used with
the SALUS Wiring Centre KL10.
The unit can be congured to be a
Programmable Thermostat (PRT), Group Control
Thermostat, Group Thermostat or hot water
timer. The units can communicate with each
other (including VS05 Dial Thermostat) when
connected to the wiring centre and using the
communication connections. More information
can be found on pages 9 and 10.
Product Compliance
This product is CE compliant and meets the
following EC Directives Electro-Magnetic
Compatibility directive 2004/108/EC
Low voltage Directive 2006/95/EC
Safety Information
Use in accordance with the regulations
The SALUS VS10 is to be used for
for room control of heating and hot water
systems inside the house.
SALUS Wiring Centre KL10
We hope you enjoy this product...
VS10W and VS10B Installer Manual 03
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:48
Product Compliance & Safety Information
Sources of danger
The thermostat must be disconnected from mains supply
before removing the cover.
Emergency
Switch o the voltage to the individual thermostat wring
centre or complete system.
Installer parameter settings
The SALUS VS10 is equipped with installer
parameter section (see page 40) this must only
be entered by the installer or competent
person. Changing these parameters can have a
serious eect on your heating system
For the installer
Please enter any parameter changes in the
installer notes section (pages 72 - 74)
230V AC
04 VS10W and VS10B Installer Manual
These instructions are applicable to the SALUS model
stated on the front cover of this manual only.
Warning
This product must be tted by a competent person, and
installation must comply with the guidance, standards
and regulations applicable to the city, country or state
where the product is installed. Failure to comply with the
requirements of the relevant guidance, standards and
regulations could lead to injury, death or prosecution.
Warning
Always isolate the AC Mains supply before
installing or working on any components that
require 230 VAC 50Hz supply.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:48
VS10W and VS10B Installer Manual 05
System Overview - Conguration Options
Programmable Room
Thermostat (PRT)
The unit can be
congured to either
one of the following
1
UFH Manifold
Wiring Centre
Radiator
Boiler
Hot Water
Group Control
Thermostat
2
Group
Thermostat
3
Timer
4
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:48
System Overview - Conguration Options
06 VS10W and VS10B Installer Manual
Programmable Room Thermostat (PRT)
When congured for PRT (see page 31) it mainly works by itself and allows the user to have separate Time and
Temperature control of each zone on the wiring centre. Features like Vacation , Party frost mode have to set on
each individual thermostat. The PRT can be congured for global Heat/Cool system changeover if your system
supports this. This is achieved from a switched input from the wiring centre (see note 6 from the wiring center
installation guide). Communication Connection (see page 13) is required to use heat/cool changeover function
Group Control Thermostat
When congured for a group control thermostat (see page 33) this allows central control of up to 7 group
thermostats see below, there can be a maximum of 2 groups per 8 zone wiring centre. Permanent temperature
override, Holiday, Party, Frost modes, can be selected centrally from the Group Control Thermostat. Holiday will
also be applied to a timer if applicable. Communication connections (see page 13) are required for grouping
the group thermostats. Thermostats can be also globally changed from heating to cooling thermostats if you
system supports this by using the switched input connection on the WC (see note 6 from the wiring center
installation guide) along with the communications connections mentioned above
Group Thermostat
When congured for Group thermostat (see page 36) and in group mode the group thermostat will follow the
time schedule and any override modes of the group thermostat. The Group thermostat can have its own
programd temperatures, manual override and also be removed from the group temporarily or permanently.
Communication connections required (see page 13).
Timer
When congured to timer (see pages 32 & 34) the unit will operate as a timer with no temp control. This can be
used for example hot water control. The timer will also follow Holiday mode from the group control thermostat
if applicable, communication connections required for this group function.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:48
System Overview - Cables
Power and Switching Cable – used to
power thermostats and drive output
Grouping and Communication cable
Communication cable can be used when units are used as individual PRT's for heat/cool
changeover. Please refer to page 13 and note 5 on the wiring centre installation guide.
While the thermostats can function as stand alone
Programmable or Timer’s, Installing this Optional inexpensive
Communication Cable allows the thermostats to communicate
with each other. This allows the thermostat to assume
convenient remote control of groups of thermostats. Bringing
central control of features such as Time control, Holiday & Party
functions as well as frost control. The individual group members
can leave or re-enter group control at the push of a button
Cable size 1.5mm 3 core for L,N,SL and 0.5mm twin for the communication.
VS10W and VS10B Installer Manual 07
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
System Overview - Options
Option 1 - Page 09
Option 2 - Page 10
Option 3 - Page 10
The systems below although not exhaustive show the main options. The
maximum number of groups per KL10 wiring centre is two. The group
selection communication cable must correspond to the group terminals
on the KL10 WC. Please refer to note 5 on the KL10 installation guide.
Group 1 Group 2
Group 1
Group 2
All Digital Variants can be
congured from VS10. Groups
must have a group control
thermostat. 1 or 2 Groups can be
used per wiring centre. HW Timer
can be stand alone or part of a
group. If using HW Timer as part
of a group it must be in group 1.
08 VS10W and VS10B Installer Manual
Option 2 - Unit is congured as a Group Control Thermostat used to control a group(s) of Dial Stat(s)
Option 3 - Unit is congured as a Group Control Thermostat used to control a group(s) of Digital Stat(s) congured as group thermostats.
Option 1 - Unit is congured as individual PRT.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
System Overview - Grouping and Communication
FUNCTION PRT USING COMMUNICATION
CONNECTION - PRT
Individual Room Control 4 4
Individual Holiday Function 4 4
Individual Party Function 4 4
Individual Heating Program 4 4
Individual Frost Function 4 4
Group Holiday including HW 6 6
Group Party 6 6
Group Heating Program 6 6
Group Permanent Override 6 6
Group Temporary Override 6 6
Heat/Cool changeover 6 4
Note: The communication connection is only used for heat/cool changeover when using
units congured to PRT’s and using the relevant connection on the KL10 Wiring Centre.
Please refer to note 6 on Wiring Centre installation guide.
Option 1 - Page 31
VS10W and VS10B Installer Manual 09
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
System Overview - Grouping and Communication
FUNCTION PRT USING COMMUNICATION
CONNECTION - GROUP CONTROL
Individual Room Control 4 4
Individual Holiday Function 4 4
Individual Party Function 4 4
Individual Heating Program 4 4
Individual Frost Function 4 4
Group Holiday including HW 6 4
Group Party 6 4
Group Heating Program 6 4
Group Permanent Override 6 4
Group Temporary Override 6 4
Heat/Cool changeover 6 4
Note HW timer will only use HOLIDAY function when the communication connection
is used. Also the HW timer must be connected to GROUP 1 communication terminals
on wiring centre. See note 8 on Wiring Centre installation guide.
Option 2 - Page 33 Option 3 - Page 35
10 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
System Overview - Hot Water Option
When the unit is congured as a hot water timer (see page 34)
there are two methods of connecting the cylinder thermostat
Unit congured to
Hot Water Timer.
Cylinder thermostat options
1 Connected direct to WC (Default)
2 Connected direct to VS10 (requires additional
parameter change. See page 40)
VS10W and VS10B Installer Manual 11
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
System Overview - Hot Water Option
1 Connected direct to WC (Default) 2 Connected direct to VS10
(requires additional parameter change see page 40)
For convenience there is a unique built in option allowing the cylinder
thermostat to be connected to either the HW Timer or Wiring Centre.
Please refer to note 1 on Wiring Centre guide and page 18 for more information.
12 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
Installation – Terminal Connections
Understanding your terminal connections
Rear of unit
Communication Terms 12VDC
Two wire twisted pair can be
used for Grouping Functions
between PRT, Group Control
Thermostat, Group Thermostat
and HW Timer.
Power Terminals 230 Vac
Used for supplying power to the
unit and switched output.
Sensor Terminals
Can be used for external AIR,
Floor sensor when congured
as thermostat. Can also be
used for Cylinder thermostat
when congured for HW.
1
3
2
1 2 3
VS10W and VS10B Installer Manual 13
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
Carefully remove the front housing.
Installation – Thermostat Mounting
1 3
2
60mm
14 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
Installation – Thermostat Mounting
Not to be positioned on an exterior wall.
Mounting position and installation
To ensure trouble free operation and ecient control, the unit is best positioned
in a draft free area and at 130cm from the oor. Do not position the thermostat
near any heat source, behind curtains, direct sunlight or an area of high humidity.
VS10W and VS10B Installer Manual 15
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
SL N L
Zone 1
Example
Group 1GND
ZONE 1
SL N L SL N L SL N L SL N L SL N L SL N L SL N LSL N L
ZONE 2 ZONE 3 ZONE 4 ZONE 5
ZONE 6 ZONE 7
ZONE 8
5 x 20mm
5 x 20mm
SL N L
Group 1GND
Installation – Thermostat Connections
While the thermostats can function as PRT or
Timer’s, Installing this Optional inexpensive
Communication Cable allows the thermostats to
communicate with each other. This allows the
thermostat to assume convenient remote
control of groups of thermostats. Bringing
central control of features such as Time control,
Holiday & Party functions as well as frost control.
The individual group members can leave or re-
enter group control at the push of a button
Optional communication
connection 12VBC
For more detail refer to note 5 on the wiring centre installation guide
16 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
Installation – Thermostat External Sensor
Note: If you are using an external sensor, the unit has to be
congured for External Air Sensor or Floor Protection Sensor
please see device parameter setting page 40.
VS10W and VS10B Installer Manual 17
INSTALLATION
SALUS External sensor (Sold separately)
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
Installation – Hot Water Timer wiring
SL N L
Zone 1
Example
Group 1GND
ZONE 1
SL N L SL N L SL N L SL N L SL N L SL N L SL N LSL N L
ZONE 2 ZONE 3 ZONE 4 ZONE 5
ZONE 6 ZONE 7
ZONE 8
5 x 20mm
5 x 20mm
SL N L
Group 1GND
Power Connections 230 Vac
Optional
Communication
Connections 12 VDC
If hot water is part
of a group then the
communication
connection must
be connected to
group 1.
18 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:50
Installation – Hot Water Timer Cylinder Thermostat
Note: The unit can be congured for Cylinder thermostat or connected to the
Hot Water Timer. Please see device parameters page 40. For additional Wiring
Centre information refer to note 1 on Wiring Centre guide.
ZONE 1
SL N L SL N L SL N L SL N L SL N L SL N L SL N LSL N L
ZONE 2 ZONE 3 ZONE 4 ZONE 5
ZONE 6 ZONE 7
ZONE 8
5 x 20mm
5 x 20mm
HW Timer connected cylinder thermostat
IN OUT
Link must be tted
ZONE 1
SL N L SL N L SL N L SL N L SL N L SL N L SL N LSL N L
ZONE 2 ZONE 3 ZONE 4 ZONE 5
ZONE 6 ZONE 7
ZONE 8
5 x 20mm
5 x 20mm
WC connected cylinder thermostat (Default)
Cylinder thermostat
SALUS CT100
IN OUT
VS10W and VS10B Installer Manual 19
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:50
Installation – Thermostat Mounting
Check that the wiring is completed for:
1
2
3
Please use the screws provided
Ensure the orientation arrow
is pointing upwards.
Power Terminals
Sensor Terminals (if applicable)
Communication connections (optional but recommended)
You are ready to secure the rear housing to the wall box
20 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:50
Installation – Thermostat Mounting
1
Fit the front housing to the rear housing
Align the front housing
at the bottom edge.
2
Lightly press until you
hear a positive click.
Ensure the pin connections are aligned
VS10W and VS10B Installer Manual 21
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:50
Installation – LCD Graphics
ICON FUNCTION
BOX means to select the mode e.g. means the current setpoint is
Hi temp, means the Hi temp is not selected.
Sunny: Hi comfortable temperature.
Cloudy: Middle comfortable temperature.
Moon: Low comfortable temperature.
Programmable thermostat Program mode indicator:
Indicates program is running, Auto On or Auto O. For group thermostat this
indicates that it is a member of a group.
Party indicator:
When Party mode is active.
Vacation indicator:
When Vacation mode is active
Frost protection indicator:
Frost protection is active, not available in cooling mode (if applicable)
22 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:50
Installation – LCD Graphics
ICON FUNCTION
Heat indicator:
Indicates heat is required.
Cool mode indicator:
Indicates cooling is required (if applicable)
Temperature indicator:
Display the room temperature.
Display the set-temp.
Also used to show the other information.
Temporary manual override indicator:
If the set temperature is changed when in program mode,
the hand will appear until the next program start time.
Programs number indicator:
In AUTO program mode or Temporary override is running,
it means the current program running.
Day indication:
1 = Monday
VS10W and VS10B Installer Manual 23
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:50
Installation – LCD Graphics
ICON FUNCTION
Hot Water (HW) indicator:
Unit has been congured for HW Timer.
Hot Water (HW) indicator:
Indicates that there is Hot Water demand.
HW Program mode indicator:
Indicates program is running.
HW Mode indicator:
Mode for 1 period of HW a day, from Program 1 ON
to Program 3 OFF.
HW Mode indicator:
Indicates continuously On.
HW Mode indicator:
Indicates continuously O.
HW Mode indicator:
Indicates Boost +1hr override.
24 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:50
Installation – LCD Graphics
ICON FUNCTION
Floor sensor probe indicator
Show only when Air + Floor sensor is connected.
Low battery indicator:
Batteries need to be replaced.
Setting indicator:
Indicate the unit is in setting mode when program setting.
Indicate the manual mode.
Keylock indicator:
Shows that keys are inactive.
VS10W and VS10B Installer Manual 25
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:50
Installation – User Interface
KEY FUNCTION
1. Increase or decrease setpoint temperature.
2. Increase or decrease Day, Clock, Timer, Party, Holiday and Boost.
3. Select installer parameter value.
1. Mode selection.
2. Long press to return to home display without saving.
3. Short press to return to the previous screen when it is in user/
installer setting mode.
1. OK key: Short press to conrm selection.
2. Long press to save and exit.
3. Long press to enter the user settings.
Lock/Unlock
Enter Installer parameter settings
Test mode
OR
+
++
LONG PRESS
LONG PRESS
LONG PRESS
+
OR
26 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:50
Installation – First Power Up
VS10W and VS10B Installer Manual 27
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:50
Installation – System Parameters
SX FUNCTION SYSTEM SETTING DEFINITION DEFAULT
SO1 System Unit 0 Programmable Stat (PRT)
Type 1 Digital Thermostat 0
2 HW Timer
S03 System 0** PRT only with communication*
Communication 1* Group control thermostat and
group thermostat communication 1
2 No Communication /
Grouping required
You are now ready to congure the unit
using the system parameter table below.
*S03 setting 1 is used for Control Group options 2 & 3 see pages 33-36, communication
connection must be used, global heat/cool changeover is also included if applicable to your system.
**S03 setting 0 is used for option 1 (see page 31) when heat/cool changeover is required for individual
PRT’s, communication connections must be used for this function. S03 setting 0 is only available if setting
0 has been selected for S01. If no heat/cool changeover is required when using PRT’s only then select
setting 2 for S03
28 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:50
Installation - Options
Option 1 - Page 31
Option 2 - Page 33
Option 2 - Unit is congured as a Group Control Thermostat used to control a group(s) of Dial Stat(s)
Option 3 - Unit is congured as a Group Control Thermostat used to control a group(s) of Digital Stat(s) congured as group thermostats.
Option 3 - Page 35
Group 1 Group 2
Group 1
Group 2
An additional Hot Water Timer can be used with any of the above options
Option 1 - Unit is congured as individual PRT.
VS10W and VS10B Installer Manual 29
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:51
Installation - Graphics Key
30 VS10W and VS10B Installer Manual
Press once
Press x amount of times
Hold for ve seconds
Flashing
xx
Short press to save and
long press to save and exit
Short press to back up
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:51
Option 1 - Individual Programmable thermostat setup
VS10W and VS10B Installer Manual 31
Long press to exit
to home screen
or continue to
change device
settings. Refer to
page 33.
Short press on
to back up.
Use to
change to 2.
PRT with no communication*
*Select S03 setting 0 if communication is required for global heat/cool changeover.
Your system must support this and the communication connection must be used. See page 13.
SYSTEM OPTION 1
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:51
Option 1 - Hot Water Timer (Optional ) Conguration
Long press to exit
to home screen
or continue to
change device
settings. Refer to
page 40.
Hot water with no communication.
32 VS10W and VS10B Installer Manual
Use to
change to 2.
Use to
change to 2.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:51
Option 2 - Thermostat Conguration
Group
Control
Thermostat
VS10W and VS10B Installer Manual 33
Long press to
exit to home
screen or
continue to
change device
settings. Refer
to page 40.
Communication
connection
required for this
setting.
SYSTEM OPTION 2
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:51
Option 2 - Hot Water Timer (Optional) Conguration
34 VS10W and VS10B Installer Manual
Long press to exit
to home screen
or continue to
change device
settings. Refer to
page 40.
Communication
connection
required for this
setting.
Use to
change to 2.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:51
Option 3 - Thermostat Conguration
VS10W and VS10B Installer Manual 35
SYSTEM OPTION 3
Group
Control
Thermostat
Long press to
exit to home
screen or
continue to
change device
settings. Refer
to page 40.
Communication
connection
required for this
setting.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
Option 3 - Thermostat Conguration
36 VS10W and VS10B Installer Manual
Group
Thermostat
Long press to
exit to home
screen or
continue to
change device
settings. Refer
to page 40.
Communication
connection
required for this
setting.
Use to
change to 1.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
Option 3 - Hot Water Timer (Optional) Conguration
VS10W and VS10B Installer Manual 37
SYSTEM OPTION 3
Long press to
exit to home
screen or
continue to
change device
settings. Refer
to page 40.
Communication
connection
required for this
setting.
Use to
change to 2.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
38 VS10W and VS10B Installer Manual
Installation - System Parameters
If you have made an error or need to change your system parameters please follow steps below.
This should only be done by your installer.
Press all three
buttons
simultaneously
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
Installation - System Parameters
Unit will follow
power up
sequence on
page 27.
You are now
ready to enter or
change your
system
parameters.
Refer to page
28.
VS10W and VS10B Installer Manual 39
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
Installation - Device parameters
Device parameters will
follow system
parameters on rst
power up. If you need
to change device
parameters follow the
steps below.
Please note, your
system parameters will
be shown rst but
cannot be edited in this
section. To change the
system parameters
please refer to the
previous two pages.
40 VS10W and VS10B Installer Manual
Press all three
buttons
simultaneously
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
Installation - Device Parameters
DX FUNCTION SYSTEM SETTING DEFINITION DEFAULT
D01 Heating 0 Pulse Width Modulation
Control 1 On-O 0.5 Deg C +/- 0.25 Deg C 0
2 On-O 1.0 Deg C +/- 0.5 Deg C
D02 Room -3.0 to 3.0 Temperature Oset from
Temperature Deg C Measured Temperature to 0 Deg C
Oset Compensate for any error
D03 Sensor probe or 0 Sensor/Cyl stat not Connected
Cylinder thermostat 1 Sensor/Cyl stat Connected 0
connection
D04 Sensor probe 0 D03 must be set to 1 then
used as air sensor external sensor be used as
or oor sensor Air sensor. There will be no
internal temp measurement
0
1 D03 must be set to 1 then
external sensor used for oor
protection. Internal temp is
measured by stat
D05 Cooling Control 1 On-O 0.5 Deg C +/- 0.25 Deg C
2
2 On-O 1.0 Deg C +/- 0.5 Deg C
D06 Actuator type 0 NO Normally Open
1
1 NC Normally Closed
D07 Valve protection 0 Disable
1
1 Enable
VS10W and VS10B Installer Manual 41
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
Installation - Device Parameters continued
DX FUNCTION SYSTEM SETTING DEFINITION DEFAULT
D08 Frost Set point 5-17 Deg C Required Temperature for frost 5 Deg
Temperature protection and holiday mode
D09 Hour Format 0 12
1
124
D10 N/A N/A N/A N/A
D11 Daylight Saving 0 OFF
1
Time (DST) 1 ON
D12 Heating Set point
5-35 Deg C
Maximum temp that can
35 Deg C
Limit be set for heating
D13 Cooling Set point
5-40 Deg C
Maximum temp that can
5 Deg C
Limit be set for Cooling
D14 Floor sensor High Output relay will be switched o
Limit Temperature 6-45 Deg C when temp is reached for 27 Deg C
oor protection
D15 Floor sensor Low Output relay will be switched on
Limit Temperature 6-45 Deg C when temp is reached for 10 Deg C
oor protection
D16 Floor sensor Limit Output relay will be switched o
for cooling 6-45 Deg C when temp is reached for 6 Deg C
oor protection
42 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
Installation - Error Codes
Error Code Prog Non-Prog HW
01 Comm Connection link failure Comm Connection link failure Comm Connection link failure
02 Comm Connection link failure Comm Connection link failure Comm Connection link failure
03 Floor sensor open Floor sensor open -
04 Floor sensor short Floor sensor short -
If there is more than 1 error, then on Error page, press UP to show other error codes.
e.g. Err 03 05 ===> 3 errors Error code 05 ( 1st one )
Press Up to show Err 03 08 ===> 3 errors Error code 08 ( 2nd one )
Press Up again to show Err 03 09 ===> 3 errors Error code 09 ( 3rd one )
Press Up again to show Err 03 05 again......
Press OK to exit Error page back to Home display.
VS10W and VS10B Installer Manual 43
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
Installation - Technical Detail
Model VS10W/ VS10B
Type Electronic programmable room thermostat, digital room
thermostat and hot water timer designed for 230V AC applications
Programming Modes User selectable for 5/2, ALL and Individual day options
Program Number 1-6 Selectable
Modes Party, Vacation, Program and Frost
Override Permanent and temporary
Frost Protection 5ºC Adjustable
Power Source 230V AC 50Hz
Rating 3 Amp
Communication Bus 12V DC
Temperature Scale 5 to 35ºC, tolerance 0.5ºC
Heat/Cool Global changeover using communication bus and external input
to the wiring centre
Sensor Air or oor protection. Cylinder thermostat when congured for
hot water timer.
Device Parameters See page xx for full list of functions
Operating Temperature 0 to 50ºC
Storage Temperature -20 to 60ºC
44 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
User Guide - Setting time and date
VS10W and VS10B Installer Manual 45
USER GUIDE
PRT and Group Control Thermostat
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Setting time and date
Use Left to select
12 hour and right
to select 24 hour.
Adjust the time
using the up or
down arrow key.
46 VS10W and VS10B Installer Manual
PRT and Group Control Thermostat
Hour
Minutes
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Setting time and date
Adjust the
year/month/day
using the up or
down arrow key.
VS10W and VS10B Installer Manual 47
USER GUIDE
PRT and Group Control Thermostat
Month
Year
Day
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Understanding Temperature Levels Heating
48 VS10W and VS10B Installer Manual
Highest Temperature typically used for
early morning and early evening.
Typically 21 Deg C
Mid Temperature typically used for times of
day when you are active around the home
Typically 19 Deg C
Lower Temperature typically used for
unoccupied or sleep times. Typically 17 Deg
C for UFH or 15 Deg C for radiators
Frost Temperature typically used for
Periods of long absence or
holidays. Typically 5 Deg
Your thermostat comes preset for the above temperatures.
These can be adjusted please see page 53
PRT, Group Control Thermostat and Group Thermostat
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Understanding Temperature Levels Cooling
Occupied Temperature. Typically 22ºC
Unoccupied Temperature Typically 40ºC
This avoids cooling being active when the property is unoccupied.
Evening Temperature Typically 24ºC
VS10W and VS10B Installer Manual 49
Your thermostat comes preset for the above temperatures.
These can be adjusted please see page 53
Cooling is only available if your system supports this and the relevant
congurations and connections have been made to the unit.
USER GUIDE
PRT, Group Control Thermostat and Group Thermostat
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Default Heating Schedule
50 VS10W and VS10B Installer Manual
21
19
17
12.00 7.00 9.00 17.00 23.00
Monday to Friday
21
19
17
12.00 8.00 9.00 17.00 23.00
Saturday to Sunday
PRT and Group Control Thermostat
If using grouping, the schedule from the group control
thermostat will be applied to group members.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Default Cooling Schedule
22
40
24
12.00 7.00 9.00 17.00 23.00
Monday to Friday
22
40
24
12.00 8.00 9.00 17.00 23.00
Saturday to Sunday
VS10W and VS10B Installer Manual 51
USER GUIDE
PRT and Group Control Thermostat
If using grouping, the schedule from the group control
thermostat will be applied to group members.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Graphics Key
52 VS10W and VS10B Installer Manual
Press once
Press x amount of times
Hold for ve seconds
Flashing
xx
Short press to save and
long press to save and exit
Short press to back up
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Setting required temp levels
By setting the
low temperature
the program
schedule will use
this as the low
setting.
The temperature
set are
applicable to the
individual
thermostat.
PRT, Group Control Thermostat and Group Thermostat
Setting the low temperature
VS10W and VS10B Installer Manual 53
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Setting required temp levels
Repeat for
Move back to once
temperature levels have
been chosen.
By setting the
low temperature
the programs
will use this as
the low setting.
54 VS10W and VS10B Installer Manual
The temperature
set are
applicable to the
individual
thermostat.
PRT, Group Control Thermostat and Group Thermostat
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide – Setting the Temperature Schedule
Use right and left
to select the day
of the programs.
VS10W and VS10B Installer Manual 55
5/2
7 Days
Individual
If using grouping, the schedule from the group control
thermostat will be applied to group members.
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide – Setting the Temperature Schedule
Adjust the time
using the up or
down arrow key.
Use right and left to
select the Hi/Mid or
low temp.
56 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide – Setting the Temperature Schedule
When you set the temperature the schedule will respond
to those temperatures see page 53 on how to change
Repeat through to program 4.
If you require a 5th or 6th program enter a time
and select your temperature
To remove a program out set the time to --:--.
VS10W and VS10B Installer Manual 57
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Temporary Override
Use the up or down
arrow key to view
your program set
temperature.
The temporary
override is applicable
to the thermostat
being changed only.
Use the up or down
arrow key to adjust
the temperature to
the setting you
desire.
Temporary override allows you to increase the
temperature or decrease it to the desired setting
until it reverts back on the next program time.
58 VS10W and VS10B Installer Manual
PRT, Group Control Thermostat and Group Thermostat
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Temporary Override
To cancel temporary override press or
See below.
VS10W and VS10B Installer Manual 59
PRT, Group Control Thermostat and Group Thermostat
Conrm the
temporary set
temperature.
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Permanent Override
To cancel permanent override select
See below.
Permanent override in a control group
thermostat will also aect the group
thermostats onless they are removed from
the group. See page 64.
Move from
to
Use the up or
down arrow key to
view your set
temperature. See
page 58.
To adjust your
permanent
override
temperature,
follow the steps
on page 58.
Repeat for
if required
60 VS10W and VS10B Installer Manual
PRT and Group Control Thermostat
Setting permanent low temperature
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Party Mode
The party mode is
an option that
enables
temperature
for a period of
time you select
up to 9hr 50min.
Use the right
arrow to select
the party mode.
Use the up
arrow to select
the hr/min.
Press tick to
conrm and
it will start to
count down .
Party Mode set in
a Control Group
Thermostat will
also aect group
thermostats
unless they are
removed from the
group.
See page 64.
VS10W and VS10B Installer Manual 61
USER GUIDE
PRT and Group Control Thermostat
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Holiday Mode
Use the right
arrow to select
the holiday mode.
Use the up arrow
to select how
many days to be
o for .
Press tick to
conrm and it will
start the holiday
count down.
62 VS10W and VS10B Installer Manual
Holiday set in a
Control Group
Thermostat will
also aect group
thermostats
unless they are
removed from the
group.
See page 64.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Frost Protection
Use the right
arrow to select
the frost mode.
Use the up arrow
to select the
frost protection
temperature.
Press tick to
conrm the
temperature
that has been
set to.
VS10W and VS10B Installer Manual 63
Frost protection set
in a Control Group
Thermostat will
also aect group
thermostats unless
they are removed
from the group.
See page 64.
Frost protection is
not available in
cooling. Moving the
to this
position in cooling
will switch the
thermostat to o.
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Group Thermostat Overview
When a group thermostat
is in it will follow
the mode status of the
group control thermostat.
When a group
thermostat is in
and the group control
thermostat is in
or then
the group thermostat
will follow this mode.
or will be
displayed.
The group thermostat
has now left the group
and is in permanent
To adjust the set
temperature, please
refer to page xx.
The group thermostat
has now left the group
and is in permanent
To adjust the set
temperature, please
refer to page xx.
64 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Group Thermostat Overview
The group thermostat
has now left the group
and is in permanent
To adjust the set
temperature, please
refer to page xx.
The group thermostat
has now left the group
and is in permanent
To adjust the set
temperature, please
refer to page xx.
The group thermostat
has been returned to
it will follow the mode
status of the group
control thermostat.
VS10W and VS10B Installer Manual 65
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Hot Water (Optional) Mode Selection
66 VS10W and VS10B Installer Manual
2
3
Mode selection
Hot water will follow
Holiday mode from the
group control
thermostat.
will be displayed.
When is
selected, the hot
water timer will follow
the program schedule.
See page 68.
Hot water will be
on once per day.
Hot water will be
continuously on.
Hot water will be
continuously o.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Hot Water Boost
VS10W and VS10B Installer Manual 67
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Default Hot Water Schedule
12.00
6.00 8.00 18.00 22.00
ON ON
OFFOFF OFF
12.00 6.00 8.00 18.00 22.00
Saturday and Sunday
Monday to Friday
ON ON
OFFOFF OFF
Your hot water timer comes preset with the times below.
These can be adjusted. See next page.
68 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Setting Hot Water Times
VS10W and VS10B Installer Manual 69
USER GUIDE
5/2
7 Days
Individual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
User Guide - Setting Hot Water Times
70 VS10W and VS10B Installer Manual
Repeat these steps for
programs
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
User Guide - Setting Hot Water Times
VS10W and VS10B Installer Manual 71
USER GUIDE
Repeat these steps for
programs
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
Installer Notes
72 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
Installer Notes
VS10W and VS10B Installer Manual 73
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
Installer Notes
74 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall
perform in accordance with its specication, for a period of ve years from the date of installation. SALUS
Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
Customer Name: .............................................................................................................................
Customer Address: ..........................................................................................................................
............................................................................... Post Code: ........................................................
Tel No: ........................................................ Email: .........................................................................
Engineers Company: .......................................................................................................................
Tel No: ......................................................... Email: ........................................................................
Instalation Date: ..............................................................................................................................
Engineers Name: ............................................................................................................................
Engineers Signature: .......................................................................................................................
VS10W and VS10B Installer Manual 75
Warranty
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
www.salus-controls.com
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.
SALES: T: +44 0 1226 323961
E: sales@salus-tech.com
TECHNICAL: T: +44 0 1226 323961
E: tech@salus-tech.com
Issue Date: April 2014 For PDF Installation guide please go to www.salus-controls.com
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specication, design and materials of products listed in this brochure without prior notice.
SALUS Controls is a member of the Computime Group
00086/2
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
76

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Salus VS10W bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Salus VS10W in de taal/talen: Engels als bijlage per email.

De handleiding is 14,01 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Salus VS10W

Salus VS10W Gebruiksaanwijzing - Nederlands - 76 pagina's

Salus VS10W Gebruiksaanwijzing - Deutsch - 76 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info