Introduction
RT310 / RT310TX / RT310RF is a digital room thermosat used to control room temperature. Device
launching heating system by shorting terminal blocks, simultaneously informing the action and
showing this information on the LCD display. Before use please read this manual carefully. Use only
AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the
cover. Do not use rechargeable batteries.
Product compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives:
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of
Conformity is available on www.saluslegal.com
Safety Information
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualied person in accordance to
national and EU regulations.
Technical specication
LCD Icon description
Button functions
RT310 Terminals description
RXRT510 Receiver terminals description
RT310 Wiring diagram
RT310RF Wiring diagram
RT310 RT310TX
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries
Receiver supply - 230 V AC
Thermostat rating max 3 (1) A -
Receiver rating max - 16 (5) A
Outputs
Voltage free
NO / COM /NC terminals
Voltage free
NO / COM terminals
Temperature range 5 - 35°C 5 - 35°C
Terminal Description
1 - COM Common Terminal
2 - NC Switched Live OFF
3 - NO Switched Live ON
Terminal Description
NO Switch Terminal
COM Common Switch Terminal
L, N Supply (230 V AC)
RT310 / RT310TX Thermostat RXRT510 Receiver
1
5
6
7
8
3
2 4
1. Turn on the LCD backlight
2. Turn On/O the Frost Mode
3. Increase button
4. Decrease button
1. Heating Mode ON
2. Frost Protection Mode ON
3. RF signal indicator (only in RT310RF)
4. Low battery status
5. Temperature unit
6. Room / setpoint temperature
5. When in Manual Mode,
ON will turn the boiler on.
6. When in Manual Mode,
OFF will turn the boiler o.
7. Receiver operates in automatic mode
according to the thermostat
8. Receiver output is controlled
by the On/O slide switch.
1 5
6
3
2
4
NO COM L N
DIP Switch Settings
L
L
L
COM
RT310TX
Thermostat
RT310TX
Thermostat
NO
N
N
N
L
L
L, N
M
N
N
M
COM
NO
NC
Kocioł
/ sterownik kotła
Połączenie bezprzewodowe
Napięcie zasilania 230 V AC
Siłownik zaworu
Pompa
Bezpiecznik
Przekaźnik beznapięciowy NO
NO
COM
NC
NO
COM
M
OR
MAX
3 (1) A
OR
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
AC 230 V
AC 230 V
MAX
16 (5) A
RT310
Thermostat
RT310
Thermostat
L
L
L
COM
RT310TX
Thermostat
RT310TX
Thermostat
NO
N
N
N
L
L
L, N
M
N
N
M
COM
NO
NC
Kocioł
/ sterownik kotła
Połączenie bezprzewodowe
Napięcie zasilania 230 V AC
Siłownik zaworu
Pompa
Bezpiecznik
Przekaźnik beznapięciowy NO
NO
COM
NC
NO
COM
M
OR
MAX
3 (1) A
OR
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
AC 230 V
AC 230 V
MAX
16 (5) A
RT310
Thermostat
RT310
Thermostat
L
L
L
COM
RT310TX
Thermostat
RT310TX
Thermostat
NO
N
N
N
L
L
L, N
M
N
N
M
COM
NO
NC
Kocioł
/ sterownik kotła
Połączenie bezprzewodowe
Napięcie zasilania 230 V AC
Siłownik zaworu
Pompa
Bezpiecznik
Przekaźnik beznapięciowy NO
NO
COM
NC
NO
COM
M
OR
MAX
3 (1) A
OR
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
AC 230 V
AC 230 V
MAX
16 (5) A
RT310
Thermostat
RT310
Thermostat
Note: If you are using the RT310RF pack, the pairing between the thermostat and the receiver
is already done.
RT310, RT310TX, RT310RF
The DIP Switches can be found on the rear of your thermostat.
Control feature TPI Span
Operation When TPI is selected on DIP
switch № 2, the DIP switch №
1 is functional. You can choose
the Cycles Per Hour between
a lower comfort level (6CPH)
and a higher comfort level
(9CPH).
When Span is selected
on DIP switch № 2,
the DIP switch № 1 is
not functional. The
temperature accuracy of
your thermostat is set to
± 0.25 °C.
868.0-868.6MHz; <13dBm
Quick Guide
1

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Salus-RT310RF

Zoeken resetten

  • Ik heb de batterijen vervangen, display was blanco, nu krijg ik geen beeld , wat doe ik fout. Resetten ook geprobeerd geen reactie Gesteld op 27-10-2022 om 21:26

    Reageer op deze vraag Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Salus RT310RF bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Salus RT310RF in de taal/talen: Engels als bijlage per email.

De handleiding is 3,31 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Salus RT310RF

Salus RT310RF Gebruiksaanwijzing - Nederlands - 2 pagina's

Salus RT310RF Gebruiksaanwijzing - Deutsch - 2 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info