MACHINE USE
The machine can operates in manual or automatic mode: to select the mode, turn the
switch (12) to the right (automaxtic mode) or to the left (manual mode) (pic. 23). The
green indicator (13) turns on when the vacuum motor starts.
Using the machine in automatic mode (A)
Automatic operations means that the vacuum starts when an electrical or pneumatic
tool is turned on.
The vacuum will automatically turn off eight seconds after the tool is turned off.
Using the machine in manual mode (M)
Manual operations means that the vacuum runs continuously.
Power on the front panel outlet socket is permanently active during manual running.
Adjusting the vacuum level
The vacuum level can be adjusted in both operating modes by turning the knob (12)
towards the "min" position until the desired power is reached.
Automatic cleaning of the filters (VERSION “E”)
The machine has a timed filter cleaning system that maintains the vacuum strength
constant.
It is also possible to perform a complete cleaning cycle as follows (pic. 19):
- switch the machine off;
- cap the vacuum sleeve;
- restart the machine keeping the sleeve capped for 15 seconds.
Suction hose setting (VERSION “M”)
For operators safety the appliance for M class dust are provided with an indicator which
operates in case of the air velocity throught the hose falling below 20 m/sec.
Check the hose diameter and set the correct value on the front panel throttle (32) (pic.
23).
To be used with genuine RUPES hoses.
Acoustic alarm operates (VERSION “M”)
In case of acoustic alarm on locate the causes (C.) and redress (R.) it with the action re-
commended in the following procedure:
C: Power set-up too low;
R: Increase the suction power;
C: The hose diameter doesn’t match with the hose set-up on the front panel;
R: Set the hose diameter knob (32) on the right diameter;
C: Clogged or bended hose;
R: Check and set straight the hose;
C: Dust bag full;
R: See dust bag “REPLACEMENT SECTION”;
C: Clogged filers;
R: See filter cartridges “REPLACEMENT SECTION”.
After operating in hazardous dust contaminated environment all appliance
parts must be considered as contaminated; before handling the appliance out
the1contaminated area or servicing it, remove all the dust from it with vacuum
or cloth, seal the dust container with the rubber cap (33), and store hose and
accessories in a sealed bag (VERSION “M”).
Wet vacuum (VERSION “E”)
Before vacuuming liquids, remove the dust bag(paper or plastic) and replace the paper
filters cartridges with polyester ones. The filters should be damp after vacuuming.
Do not operate with dry dust with wet filters!
Liquid level indicator (VERSION “E”)
The vacuum motor stops and the liquid level indicator (14) turnes on when the the liquid
sensor (24) detects the bin (25) full. To reset empty the bin (25).
MAINTENANCE
A yearly technical check on parts and filtering system by an authorized ser-
vice centre is required.
Service indicator (15)
The indicator turns on for scheduled service to keep the machine working conditions.
When warning light is on contact an authorized service centre to check and service the
appliance and reset the warning light.
The prolongated use of the vacuum cleaner with the warning light on can cause more
maintenance operation.
Ordinary check operations
For user servicing, the appliance must be dismantled, cleaned and serviced,
as far as it is reasonably practicable, without causing risk to the maintenance
staff and others. Suitable precautions include, decontamination before di-
smantling, provision for local filtered exhaust ventilation where the appliance
is dismantled (according to local regulations), cleaning of the maintenance
area and suitable personal protection.
- check the vacuum hose conditions;
- VERSION "E": clean the liquid level sensor (24);
- check the power cord, plug and outlet socket conditions: in case contact an authorized service
centre for replacement;
- check the dust bag: do not exceed recommended weight and capacity! In case of laceration or
perforation of the dust bag check the filter cartridge and eventually ask for replacement to an
authorized service centre;
- check filter cartridges condition (23). In case of lacerations or perforations contact an authjo-
rized service centre for replacement.
Do not use the appliance without the full filter set fitted!
Bag replacement
Do not spread dust during dust bag replacement!
- wear an adeguate dust mask;
- detach the vacuum head pushing the side hooks (11) and remove the vacuum head (1) (pic.
7-8).
Paper bag (cod. 042.1108/5):
- VERSION “M”: seal the dust container with the appropriate cap (33);
- remove the full bag closing the nozzle with the cap provided (pic. 12 and 13);
- put the new bag inserting the nozzle as illustrated (pic. 14).
Plastic bag:
- remove the full plastic bag (pic. 9);
- place the new bag, verifying that the nozzle is positioned on the inlet (pic. 10);
- turn the bag edge as shown (pic. 11); make sure to keep the compensation holes inside the
bin.
Only use genuine RUPES dust bags.
Spare bags shozuld be kept in dry places!
Follow local legal regulations for disposal.
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Rupes S145 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Rupes S145 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools, Turks, Deens, Zweeds, Noors, Fins als bijlage per email.

De handleiding is 2,44 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info