Introduction Battery installation
Probe connection
How to measure
Preview Default Setting
How to Change Default Setting
Rossmax Handheld Pulse Oximeter is used to measure oxygen saturation in blood
(SpO2) and pulse rate, also to issue warnings immediately. It is a non-invasive
device intended for spot-check of adults, child, and infants with corresponding
probe applied at home, hospital and clinics. The probe contains a dual light
source and a photodetector.
Attention: Consult the accompanying documents. Please read this manual
carefully before use. Please be sure to keep this manual.
1. Use thumb to slide battery cover out.
2. Insert or replace 4 “AA” batteries according to the (+/-) polarity.
Caution: Need to replace when the batteries icon “ ” is blinking on display/
while pressed the function button and nothing appears on display.
Caution: Batteries may leak or explode if used or disposed of improperly. Remove
batteries if the device will be stored for long time. Do not use different
types or brand of batteries at the same time.
Rossmax PA100/ PC100 or compatible probe is used. (Please install carefully.)
Caution: It may damage the efficiency of the device if not apply with a Rossmax
compatible probe.
1. Press the Power On button for 1 second, when the device activates, the beep
sound will last for 2 second.
Note: After the device activates, the software version will pop up directly. For first
time activates, it will directly jump to time setting. (Please refer to setting
instruction.)
2. Information of software version appears; insert one finger to probe, nail side up,
for self-test.
Notes: The device will turn itself off automatically after 1 minute idling with two
beep sounded.
3. The pulse strength shows “ , pulse oximeter begins its measurement.
Notes: The heartbeat is sounded though the buzzer. If need to become silence
mode, press the sound button and the LCD screen will have the sound
icon shown. If need the heartbeat sound, press the sound button to exit.
4. Your SpO2 and pulse rate values will appears on the screen after few seconds.
Notes: 1. Don’t remove your finger until the measurement is completed.
2. Any other problems or unrecognized icon, please refer to trouble shooting.
1. Press the button 1 second to preview default setting value.
2. Press to exit preview default mode or wait for 3 second for automatically.
Press the button 2 second to
enter the set up mode and change
default. For jump to next setting,
press after finishing. To exit, press
or wait for 10 second.
SPO2 mode
To setup Max SpO2 rate, press
to enter, and it shows as
picture and press / button
for adjustment. To set up Min SpO2
rate, press , and it shows
as picture and same as max setting.
Pulse Rate mode
To setup Max Pulse rate, press
to enter, and it shows as
picture and press / button
for adjustment. To set up Min Pulse
rate, press , and it shows
as picture and same as max setting.
Memory interval mode
1. Optional of SA120: 5 / 10 / 30 / 60
minutes.
2. While the memory mode, the
memory interval mode
appears on the screen. To
change the default, press /
to change (5)-(10)-(30)-(60) or
(60)-(30)-(10)-(5) minutes.
Sound volume control
For the control of sound volume,
for loud volume, for lower
volume. To change the sounds
volume, Press / to change
--> .
Time Setup
To set up the time, it starts from
year as picture, and press /
to adjust. Following the same
frequency for month, date, hour
to minutes.
Warning: Press or wait for 10 seconds to exit, the setup value will be reserved.
Please double-check the set value before use.
Name/ Functions of each part
Pulse Oximeter
2
4
3
1
10
11
12
9
8
6
7
5
No. Item Purpose
1Pulse strength
2Probe icon
3LCD backlight button For light on/ o
4Sound button
For Heartbeat sound
loud volume
lower volume
silence
5 Time Shows the time
6SpO2 icon High SpO2
Low SpO2
7Pulse Rate High Pulse Rate
Low Pulse Rate
8UP/DOWN button For adjust/view all setting/ memory
memory icon
9Set button For view/ adjust default setting
10 Alert button Alert o / Alert pause
11 Power button Power on/ o
12 Battery compartment
For install or replace batteries
Full batteries
out of batteries
SA120 All symbols
SA120 All symbols
SA120 All symbols
SA120 All symbols
SA120 All symbols
SA120 All symbols
SA120 All symbols
SA120 All symbols
SA120 All symbols
1
second
2 seconds
High SpO2
Low SpO2
100
99
98
97
.
.
90
88
86
84
82
.
.
SA120 All symbols
SA120 All symbols
SA120 All symbols
SA120 All symbols
High
Pulse Rate
Low
Pulse Rate
140
135
130
125
55
50
45
40
35
SA120 All symbols
Memories reading and delete
Enter the memory mode with the or to read the SpO2 and pulse rate in
memory mode.
Note: When entering the memory reading mode, the will appear on the
screen.
SA120 All symbols
SA120 All symbols
SA120 All symbols
2
seconds
2 seconds to
clean data
Press for two second during the memory reading mode, it will enter the
memory delete mode. The screen show and means not to delete any
data, while the screen with and , it means to delete data.
Caution: The deleted data could not be restored.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Rossmax SA120 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Rossmax SA120 in de taal/talen: Engels als bijlage per email.

De handleiding is 5.03 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info