603202
174
Verklein
Vergroot
Pagina terug
1/184
Pagina verder
174
MIDI Implementation
Examples of Actual MIDI Messages
<Example1> 92 3E 5F
9n is the Note-on status, and n is the MIDI channel number. Since 2H = 2, 3EH = 62, and
5FH = 95, this is a Note-on message with MIDI CH = 3, note number 62 (note name is D4),
and velocity 95.
<Example2> CE 49
CnH is the Program Change status, and n is the MIDI channel number. Since EH = 14 and
49H = 73, this is a Program Change message with MIDI CH = 15, program number 74.
<Example3> EA 00 28
EnH is the Pitch Bend Change status, and n is the MIDI channel number. The 2nd byte (00H
= 0) is the LSB and the 3rd byte (28H = 40) is the MSB, but Pitch Bend Value is a signed
number in which 40 00H (= 64 x 12+80 = 8192) is 0, so this Pitch Bend Value is
28 00H - 40 00H = 40 x 12+80 - (64 x 12+80) = 5120 - 8192 = -3072
If the Pitch Bend Sensitivity is set to 2 semitones, -8192 (00 00H) will cause the pitch to
change -200 cents, so in this case -200 x (-3072) (-8192) = -75 cents of Pitch Bend is being
applied to MIDI channel 11.
<Example4> B3 64 00 65 00 06 0C 26 00 64 7F 65 7F
BnH is the Control Change status, and n is the MIDI channel number. For Control Changes,
the 2nd byte is the control number, and the 3rd byte is the value. In a case in which two or
more messages consecutive messages have the same status, MIDI has a provision called
“running status” which allows the status byte of the second and following messages to be
omitted. Thus, the above messages have the following meaning.
B3 64 00 MIDI ch.4, lower byte of RPN parameter number: 00H
(B3) 65 00 (MIDI ch.4) upper byte of RPN parameter number: 00H
(B3) 06 0C (MIDI ch.4) upper byte of parameter value: 0CH
(B3) 26 00 (MIDI ch.4) lower byte of parameter value: 00H
(B3) 64 7F (MIDI ch.4) lower byte of RPN parameter number: 7FH
(B3) 65 7F (MIDI ch.4) upper byte of RPN parameter number: 7FH
In other words, the above messages specify a value of 0C 00H for RPN parameter number
00 00H on MIDI channel 4, and then set the RPN parameter number to 7F 7FH.
RPN parameter number 00 00H is Pitch Bend Sensitivity, and the MSB of the value indicates
semitone units, so a value of 0CH = 12 sets the maximum pitch bend range to +/-12
semitones (1 octave). (On GS sound generators the LSB of Pitch Bend Sensitivity is ignored,
but the LSB should be transmitted anyway (with a value of 0) so that operation will be
correct on any device.)
Once the parameter number has been specified for RPN or NRPN, all Data Entry messages
transmitted on that same channel will be valid, so after the desired value has been
transmitted, it is a good idea to set the parameter number to 7F 7FH to prevent accidents.
This is the reason for the (B3) 64 7F (B3) 65 7F at the end.
It is not desirable for performance data (such as Standard MIDI File data) to contain many
events with running status as given in <Example 4>. This is because if playback is halted
during the song and then rewound or fast-forwarded, the sequencer may not be able to
transmit the correct status, and the sound generator will then misinterpret the data. Take
care to give each event its own status.
It is also necessary that the RPN or NRPN parameter number setting and the value setting
be done in the proper order. On some sequencers, events occurring in the same (or
consecutive) clock may be transmitted in an order different than the order in which they
were received. For this reason it is a good idea to slightly skew the time of each event (about
1 tick for TPQN = 96, and about 5 ticks for TPQN = 480).
* TPQN: Ticks Per Quarter Note
Example of an Exclusive Message and
Calculating a Checksum
Roland Exclusive messages (RQ1, DT1) are transmitted with a checksum at the end (before
F7) to make sure that the message was correctly received. The value of the checksum is
determined by the address and data (or size) of the transmitted Exclusive message.
How to calculate the checksum
(hexadecimal numbers are indicated by “H”)
The checksum is a value derived by adding the address, size, and checksum itself and
inverting the lower 7 bits.
Heresanexampleofhowthechecksumiscalculated.WewillassumethatintheExclusivemessage
wearetransmitting,theaddressisaabbccddHandthedataorsizeiseeffH.'
aa + bb + cc + dd + ee + ff = sum
sum ÷ 128 = quotient ... remainder
128 - remainder = checksum
<Example1> Setting CHORUS TYPE of PERFORMANCE COMMON to DELAY (DT1)
According to the “Parameter Address Map” (p. 162), the start address of Temporary
Performance is 10 00 00 00H, the offset address of CHORUS at PERFORMANCE COMMON
is 04 00H, and the address of CHORUS TYPE is 00 00H. Therefore the address of CHORUS
TYPE of PERFORMANCE COMMON is;
10 00 00 00H
04 00H
+) 00 00H
10 00 04 00H
DELAY has the value of 02H.
So the system exclusive message should be sent is;
F0 41 10 00 10 12 10 00 04 00 02 ?? F7
(1) (2) (3) (4) (5) address data checksum (6)
(1) Exclusive Status (2) ID (Roland) (3) Device ID (17)
(4) Model ID (XV-5050) (5) Command ID (DT1) (6) End of Exclusive
Then calculate the checksum.
10H + 00H + 04H + 00H + 02H = 16 + 0 + 4 + 0 + 2 = 22 (sum)
22 (sum) ÷ 128 = 0 (quotient) ... 22 (remainder)
checksum = 128 - 22 (remainder) = 106 = 6AH
This means that F0 41 10 00 10 12 10 00 04 00 02 6A F7 is the message should be sent.
<Example2> Getting the data (RQ1) of Performance Part 3 in USER:03
According to the “Parameter Address Map” (p. 162), the start address of USER:03 is 20 02 00
00H, and the offset address of Performance Part 3 is 00 22 00H.
Therefore the start address of Performance Part 3 in USER:03 is;
20 02 00 00H
+) 00 22 00H
20 02 22 00H
As the size of Performance Part is 00 00 00 31H, the system exclusive message should be
sent is;
F0 41 10 00 10 11 20 02 22 00 00 00 00 31 ?? F7
(1) (2) (3) (4) (5) address data checksum (6)
(1) Exclusive Status (2) ID (Roland) (3) Device ID (17)
(4) Model ID (XV-5050) (5) Command ID (RQ1) (6) End of Exclusive
Then calculate the checksum.
20H + 02H + 22H + 00H + 00H + 00H + 00H + 31H = 32 + 2 + 34 + 0 + 0 + 0 + 0 + 49
= 117 (sum)
117 (sum) ÷ 128 = 0 (quotient) ... 117 (remainder)
checksum = 128 - 117 (remainder) = 11 = 0BH
This means that F0 41 10 00 10 11 20 02 22 00 00 00 00 31 0B F7 is the message should be sent.
XV-5050_e.book 174 ページ 2003年6月27日 金曜日 午後3時14分
174

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Roland XV5050 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Roland XV5050 in de taal/talen: Engels als bijlage per email.

De handleiding is 6,74 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Roland XV5050

Roland XV5050 Gebruiksaanwijzing - Nederlands - 183 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info