32
Accoustic levels
The values given are the emission levels; these are not necessary the levels at which the operator can work
safely.
Alhough there is a link between the emission values and the exposion level, it cannot be used in a reliable
way to determine if supplementary measures should be taken.
Noise information
Measurements as per ISO Norm 7960; Annexe D
Workpost under load Level continuous Level accoustic Max. value accoustic
accoustic pressure as power pressure as per index
per index A C (instantaneous)
dB (A) dB (A) (MW) dB
planer 92 98(6,3) < 130
Normal and prohibited use
The machine is designed for the following work and is equiped with protective devices for these processes
only.
- planing the wide surface of workpieces on the planer unit;
- planing the narrow side of workpieces on the planer unit;
- beveling an edge on workpieces on the planer unit;
It is not designed to work materials such as ferrous and non-ferrous metals, work different from that stated
below is prohibited.
PROHIBITED USE
- insertion cuts on the planer unit, i.e. when the workpiece is not worked along its entire length;
- the use of other materials than wood, such as ferrous or non-ferrous materials.
REMAINING RISKS
- unintentional contact of the hands with the running planer arbor;
- workpiece kickback;
- tipping over of the workpiece due to insufficient support;
- ejection of knots, ect.
The above does not negate the fact that extra safety equipment such as safety gloves and ear protection must
be used.