Electrical connection (fig. 3-4)
The electrical connection must be carried out by a qualified electrician who is able to
calculate exactly the required wire section and amperage of the fuses.
- Check that the mains voltage of your machine corresponds with the voltage in your
workshop; then open the electrical connection box at the back of the machine.
- Connect the 3 phases to the terminals marked LI, L2, L3 (fig.3).
- If there is a neutral conductor (blue), it is connected to the terminal N.
- Connect the earth (green+yellow) to the terminal marked with the earth symbol.
WARNING:
- Check if the spindle runs freely and if all protections are mounted before starting up the
machine.
- If the rotation direction of the spindle is not correct, the wires Ll and L2 must be exchanged
(the rotation direction of the spindle is anticlockwise = left).
This may only be done without tools on the spindle (safety reasons)
fig.3
fig.4
Connector box
Connector terminal