TECHNICAL SPECIFICATIONS:
Minimum water pressure : 1,5 bar
Recommended water pressure : 2-5 bar
Maximum water pressure : 5 bar
Hot water temperature : max. 70 °C
Recommended water temperature : 60 °C
Safety blocking system : 38 °C
Minimum capacity : 60ºC-8L/min
Maximum flow capacity:
Hand shower : 9 l/min
Head shower : 20 l/min
Vertical hydro massage (jets) : 17 l/min
Drain via ø40mm tube : 24 l/min
Minimum innderdiameter water supply : 15 mm
Majestic 90x90 / Majestic 90x100
RI_MP Basic board
Inlet, Outlet, Valve3, Valve4 : 12VDC @ 700mA (8.4W)
Valve 5
Buzzer : 12VDC @ 250mA
Light 12VAC : 12VAC @ 20W
Heater 1 : 230VAC @ 2kW
Heater 2 : 230VAC @ 1kW (triac-controlled)
Main Supply : 230VAC
Temp : for NTC resistor (5VDC max)
Keyboard basic 1 and 2 : for keyboard connection (5VDC max)
Keyboard prof : for keyboard prof (5VDC max)
Input 1, Input 2 : Not active 0 2.0 VDC or open
Active 6 - 20 VDC
12VDCmax @ 6 mA
Water detection system : for detecting the water level, open or ground Max 5VDC
RI_EXT Extension board
Valve 6 Valve 15 : 12VDC @ 700mA (8.4W) Maximum 3 valves On simultaneously
Relay : 24VDC or AC max 500mA alternating contact
RI_RAFM Radio module (stereo)
Antenna : Antenna signal for 50ohm systems (No DC voltage)
CD : 775mVAC (1VAC max) (No DC voltage)
Speaker L and Speaker R : 7W @ 8 ohm
Majestic (A) version
Majestic (A) version
The manufacturer refuses to accept any liability in
the following cases:
! the national guidelines and standards that apply to
earthing, potential and electrical installations in
bathrooms, are not adhered to.
! the guidelines of the national laws and standards
that apply safety in bathrooms are not adhered to
! the instructions described in this manual are not
adhered to.
The cabins are dismantled once they have been
checked in the factory, to facilitate transportation and
delivery to the room in which they will be installed. It is
recommended that all the components of the shower
cabin be checked carefully before installation. Any
damage claimed after installation will not be
covered under the warranty.
SAFETY MEASURES DURING INSTALLATION
It is recommended that the bottom of the shower tray
be covered with plastic foil and cardboard in order to
prevent remnants of solid matter from damaging the
surface of the shower cabin, or blocking the drain
outlet. For all glass plates, maintain the protective strip
and protective corners on the bottom as long as
possible during installation, primarily when resting on
the shower tray. This also applies to the glass of the
technical panel. ATTENTION: It is prohibited to use
silicones containing acetyl during the installation of
the shower cabin.
After the installation, check:
- whether the water is being drained out properly.
- for leakages if any.
- whether the union nuts of the electrical cabinet have
been tightened adequately.
- whether the cover of the electrical cabinet has been
closed properly.
- whether the cabin is functioning properly.
When pushing a PE-hose into a push-in coupling for the
second time, cut-off the damaged part in order to
prevent possible leakages.
ELECTRICAL SAFETY
The shower cabin Majestic Prof is an appliance of the
Class "I".
The cabin should have a stable and durable connection to
the mains current and to the earthing installation with a
potential equaliser.
The Prof model has functions that can be programmed
using the electronic installation.
The earthing, potential and electrical installation of
the bathroom should be efficient and should satisfy
nationally applicable laws and standards.
The Prof model should be connected to an electrical
installation which has an earth leakage circuit
breaker of 30 mA.
The proper working for the switch should be checked
periodically (test).
! The earth leakage circuit breaker should have a
resistance of less than 4 Ohms.
! The shower cabin is equipped with a terminal for a
potential equaliser for a cable of 4 to 6 mm². This is
used to obtain the potential equalisation of metal
masses.
! The connection to the mains must be made using a
cable of H05 V VF-F, tripolar, with a nominal diameter
of 3x2.5 mm² and an omnipolar switch with a contact
opening of at least 3 mm, suitable for a charge of at
least 230V and a current of 16A, and should
preferably be placed outside the bathroom.
Safety regulations for bathrooms.
Electrical sockets, lamps, switches and/or other electrical
equipment should be installed outside the danger zones
indicated in the national guidelines and standards.
The regulations forbid the location of an electrical
installation in a zone that is not suitable. The switch and
other electrical devices should be placed in an area that is
inaccessible to
the person using the shower cabin.
Zone 1
Zone 3
Zone 2
40

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Riho MAJESTIC Prof bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Riho MAJESTIC Prof in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 60,1 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info