Model number RMV
User’s Manual
PLEASE READ THE USER’S
MANUAL CAREFULLY BEFORE
USING THIS PRODUCT
USE ONLY AS DIRECTED
If symptoms persist, consult
your healthcare professional
®
®
2296_IFU01_9608705.indd 1 17/07/2015 12:28
2
2296_IFU01_9608705.indd 2 17/07/2015 12:28
3
Table of contents - REVITIVE Advanced Performance
What is inside the box? 4
Parts and Controls 5
Introduction to REVITIVE 6
Indications for use 6
How REVITIVE Advanced works 7
Important Safeguards 8
Contraindications 8
Warnings, Risks and Cautions 9-11
Instructions for use 12-23
How long should I use REVITIVE? 12
Step 1: Setting up REVITIVE Advanced for the first time 12
Step 2: Setting up REVITIVE Advanced for use 13-14
Step 3: Using the foot pads 15-17
Step 4: Using the body pads 18-22
Step 5: Cleaning and storing 23
Replacing the batteries 23
Replacing the body pads 23
Troubleshooting 24-25
Technical Specifications 26-27
Warranty 28-29
2296_IFU01_9608705.indd 3 17/07/2015 12:28
4
A
B
E
What is inside the box?
On opening the carton, please check that the following components
are provided. If you think anything is missing, please contact us using the
helpline numbers on the back of this booklet.
F
AC/DC power adaptor
REVITIVE Advanced
C
D
Electrode Body Pads
Body pad cord
Remote control
AAA batteries x 2
2296_IFU01_9608705.indd 4 17/07/2015 12:28
5
G
J
I
L
M
H
K
Carry handle
Control panel/display
Power ON/OFF
Foot pads
AC/DC power
adaptor socket
Body pads socket
IsoRocker
Time display
Intensity level
Controls of REVITIVE Advanced
Remote control
Control panel
Parts and Controls of REVITIVE Advanced
Parts of
REVITIVE Advanced
N
IsoRocker Disabler
Intensity Control – /+
Intensity Control – /+
Power
ON/OFF
2296_IFU01_9608705.indd 5 17/07/2015 12:28
6
Introduction to REVITIVE
INDICATIONS FOR USE
Help maintain leg vein health by increasing circulation, delivering
more oxygenated-blood and reducing swelling (oedema) in the legs,
feet and ankles.
The above Indication for Use is certified by SGS United Kingdom Limited
NB0120 under the Medical Devices Directive 93/42/EEC
INTENDED PURPOSE
REVITIVE devices are indicated for electrical stimulation of the lower leg to:
Support and improve blood circulation, due to prolonged inactivity
and/or a sedentary lifestyle, in healthy individuals
Reduce swelling volume and discomfort in the lower leg, foot and
ankle due to prolonged inactivity and/or a sedentary lifestyle, in
healthy individuals
The above Intended purpose is included on the Australian Register of
Therapeutic Goods (ARTG)
2296_IFU01_9608705.indd 6 17/07/2015 12:28
7
HOW REVITIVE WORKS
REVITIVE delivers electrical stimulation to your feet via a pair of cushioned
foot pads, while you are seated. The electrical stimulation causes muscles
in your calf and foot to contract, which helps to increase circulation in your
lower legs.
REVITIVE Advanced has been developed so that it is comfortable for you to
use. It features an IsoRocker (patent pending) that allows for natural ankle
movement when applying the electrical stimulation to your feet. Ankle
movement is a key factor in increasing circulation in the lower legs. You can
choose to enable or disable the IsoRocker at any time.
REVITIVE Advanced is designed to be easy to use and also comes with
a remote control, which means you do not have to reach down to adjust
settings during use.
REVITIVE Advanced can also deliver electrical stimulation to the
knees, shoulders, back or arms through the use of the Electrode
Body Pads provided.
Visit www.revitive.com.au for more information
2296_IFU01_9608705.indd 7 17/07/2015 12:28
8
IMPORTANT SAFEGUARDS
READ ALL INSTRUCTIONS BEFORE USE
WHO SHOULD NOT USE REVITIVE
REVITIVE should not be used by some people.
Do not use if (contraindications):
Fitted with an electronic implanted device such as a heart pacemaker or
Automatic Implantable Cardioverter Defibrillator (AICD)
You are pregnant
Being treated for, or have the symptoms of, an existing Deep Vein
Thrombosis (“DVT”)
Long periods of inactivity can put you at greater risk of developing Deep Vein Thrombosis
(DVT). DVT is a blood clot and usually occurs in a deep leg vein. If part of the DVT breaks off
it may lead to potentially life-threatening complications such as pulmonary embolism.
If you have been inactive for prolonged periods and suspect you may have a DVT, consult your
doctor immediately. To prevent dislodging the clot do not use REVITIVE.
In some cases of DVT there may be no symptoms. However it is important to be aware of the
symptoms that may include:
pain, swelling and tenderness in one of your legs (usually your calf)
a heavy ache in the affected area
warm skin in the area of the clot
redness of your skin, particularly at the back of your leg, below the knee
Consult your doctor as soon as possible if you show any signs of the above symptoms.
2296_IFU01_9608705.indd 8 17/07/2015 12:28
9
Warnings
If you have an existing medical condition, consult with your doctor
before use.
If you have a history of heart problems, consult your doctor before using
this device.
If you are unsure about the suitability of the REVITIVE Advanced for you or
unsure about the cause of your symptoms, you should consult with your doctor
before use.
Do not use the body pads on your head, face, neck or chest.
Do not apply body pads directly:
on open wounds or rashes, swollen, red, infected, or inflamed
areas or skin eruptions (such as phlebitis, thrombophlebitis,
varicose veins, cellulitis)
on or close to, malignant tumours
on areas treated with radiotherapy (within the past 6 months)
on reproductive organs
Do not use body pads after their expiration date.
There is a chance you may experience skin irritation or burns beneath
the stimulation electrodes or hypersensitivity due to the electrical
stimulation.
Symptoms may worsen during the initial treatment phase before getting
better. This may occur if the body has not yet adjusted to increased muscular
activity and blood circulation. If this occurs, reduce the intensity and the
duration of treatment which will reduce the initial symptoms, if symptoms
persist consult with your doctor.
If you experience adverse reactions, stop using REVITIVE Advanced and talk
with your doctor.
2296_IFU01_9608705.indd 9 17/07/2015 12:28
10
Cautions
Be careful when applying stimulation:
over areas of skin that lack normal sensation. It may cause
skin irritation due to the inability to feel stimulation until the
intensity is too high - use a low intensity to achieve a gentle
muscle contraction, and/or use for a shorter time, to avoid
overstimulation.
over the abdomen during menstruation.
after recent surgical procedures as stimulation may disrupt your
healing process.
If your tissues are likely to bleed following an injury such as a
muscle tear – it is recommended not to stimulate the immediate
area within the first 12 hours after sustaining the injury. Use a low
intensity and/or shorter time to avoid over-stimulation.
after a long period of immobility or inactivity – use a low intensity
and shorter time to avoid overstimulation or muscle fatigue.
Look for signs of skin irritation (redness), bruising or pain. If in doubt,
consult your doctor.
The long-term effects of electrical stimulation are unknown.
This product is not intended for use by persons with reduced physical,
sensory or mental capabilities, unless they are supervised by a person
responsible for their safety.
Safety Precautions
Do not stand on the machine. Use only when sitting down.
Use the device only for its intended purpose.
Do not expose the device to extreme heat.
IMPORTANT SAFEGUARDS
2296_IFU01_9608705.indd 10 17/07/2015 12:28
11
Do not spill liquid on the device or its accessories.
Do not overload the electrical outlet.
Not suitable for use by children.
Use the REVITIVE Advanced only with the accessories supplied by, or
purchased from, the manufacturer.
Do not open the REVITIVE Advanced or repair it yourself. This will
invalidate your warranty and may cause serious harm.
In the unlikely event your REVITIVE malfunctions, disconnect it from the
power source and contact your nearest authorized agent.
With the increased number of electronic devices such as personal
computers and mobile (cellular) telephones, medical devices may be
susceptible to electromagnetic interference from other devices. The
REVITIVE has passed the required tests for Electromagnetic
interference (EMI), it may still be affected by excessive emissions and/
or may interfere with more sensitive equipment.
It has been reported that some universal remote control devices (eg for
TV etc) can change the settings on REVITIVE if used during a treatment.
If this should occur, simply adjust the time or intensity settings on
REVITIVE back to where you want them to be using the REVITIVE
Remote Control, or using the device Control Panel.
After any exposure to hot or cold temperatures outside the specified
operating range of 10 – 40°C allow the product to re-adjust to the
recommended operating temperatures to ensure continued product
performance.
SAVE THESE INSTRUCTIONS
2296_IFU01_9608705.indd 11 17/07/2015 12:28
12
Instructions for use
STEP 1:
SETTING UP REVITIVE FOR THE FIRST TIME
a Remove all parts from the carton:
AC/DC power adaptor
REVITIVE Advanced
Body pads
Body pad cord
Remote control
AAA batteries x 2
See What is inside the Box? on pages 4-5 to help identify the parts.
b Locate the remote control and insert the batteries.
Before you use REVITIVE Advanced for the first time, read the Warnings
and Cautions on pages 7-10. If in doubt, consult your doctor before using
the product.
How long should I use REVITIVE?
It is recommended to use REVITIVE Advanced for
20-30 minutes per day.
Do not use REVITIVE Advanced more than 6 sessions of
30 minutes (or the equivalent) per day. This may result
in muscle fatigue.
2296_IFU01_9608705.indd 12 17/07/2015 12:28
13
STEP 2:
SETTING UP REVITIVE FOR USE
a Turn the device over so that you can see the
IsoRocker and the IsoRocker Disabler.
• The IsoRocker allows REVITIVE Advanced to rock
while stimulating your legs and feet.
REVITIVE Advanced will begin rocking on the
IsoRocker once muscle contractions are strong
enough.
• The Isorocker feature can be disabled, by opening
the IsoRocker Disabler. REVITIVE Advanced will
then be static and it will not rock during use.
b If you want to use the IsoRocker, leave the IsoRocker
Disabler in place (ie flat) on the bottom of the device,
as shown.
c If you do not want to use the IsoRocker
• Open the IsoRocker Disabler on the bottom of
REVITIVE Advanced. You may have to pull hard.
• Pull the IsoRocker Disabler back until it clicks open,
as shown.
• To re-enable the IsoRocker, pull the IsoRocker
Disabler and press into place on the bottom of
the device (ie flat).
2296_IFU01_9608705.indd 13 17/07/2015 12:28
14
Instructions for use
d Locate the AC/DC power adaptor.
e Plug the small end of the power cord into the
opening on the side of the REVITIVE Advanced.
f Plug the power adaptor into the nearest
electrical socket.
2296_IFU01_9608705.indd 14 17/07/2015 12:28
15
STEP 3:
USING THE FOOT PADS
a Get into a comfortable seated position.
For best results sit with your knees at a 90 degree angle
(right angle).
b Place REVITIVE Advanced on the floor in front of you.
REVITIVE Advanced is designed to be used while
seated. Never stand on the REVITIVE unit.
c Place both bare feet on the foot pads.
Make sure you remove all footwear, including socks/
stockings.
d If desired, apply a moisturising lotion to the soles of
your feet.
Hint: Applying a moisturising lotion to the soles of the
feet before using REVITIVE Advanced can help improve
the delivery of electrical stimulation.
e Press the power button on the device or on the remote
control to turn REVITIVE Advanced on.
You will hear a beep and the display lights will light up.
The time will read 30 minutes and Intensity will
read 00.
To turn off REVITIVE at any time during operation, press
the power button on the device or remote control.
R
R
Sit with
both bare feet
on the foot pads
2296_IFU01_9608705.indd 15 17/07/2015 12:28
16
Instructions for use
f Press the (+) Intensity Control one time to
start stimulation.
Continue to increase the intensity until you can feel or
see the muscles in your calves contract and relax. You
can set the intensity between 1-99.
You can use the buttons on the control panel or
remote control.
Press the (+) button to increase the level.
Press the (–) button to decrease the level.
g Use an intensity that provides you with strong but
comfortable muscle contractions and note that the
intensity required may vary from day to day - eg using it
on 25 one day, does not necessarily mean you will need
to use if at 25 the next day. The required intensity could
be higher or lower than previous usage.
It is normal to feel tingling or varying sensations in
your calf muscles.
If you feel pain or discomfort:
• Remove one or both feet from the foot pads to
stop the stimulation.
Lower the intensity of the foot pads using the
(–) Intensity Control on the control panel or
remote control before replacing your feet on
REVITIVE Advanced.
REVITIVE Advanced does not vibrate.
2296_IFU01_9608705.indd 16 17/07/2015 12:28
17
h The Time Display will start to count down
in minutes as the device cycles through its program.
i When REVITIVE Advanced times out, the Time
Display reads 00 and you will hear three beeps.
j REVITIVE Advanced switches itself off automatically.
2296_IFU01_9608705.indd 17 17/07/2015 12:28
18
Instructions for use
STEP 4: USING THE ELECTRODE BODY PADS
REVITIVE Advanced comes with two pairs of reusable (up to 20-30
applications) body pads that can be used to deliver electrical stimulation to
target specific body areas such as knees or thighs.
a Select the area you wish to apply electrical stimulation to.
Example body pad placements are shown below:
Do NOT use the body pads on your head, face, neck or chest.
Thigh
Knee
2296_IFU01_9608705.indd 18 17/07/2015 12:28
19
b Clean and dry the area where you will place the
body pads.
c Make sure REVITIVE Advanced is switched off. If the
control panel is still illuminated, press the power button
and turn REVITIVE Advanced off.
d Attach the ends of the body pads to the body
pad cord.
Press connectors until no gap is between them.
Leaving a gap may cause discomfort.
e Plug the other end of the body pad cord into the
opening on the side of REVITIVE Advanced.
Plugging in the body cord will automatically turn
the foot pads off and intensity will reset to zero.
f Remove the plastic liner from the body pads, by
peeling it off carefully. Replace the body pads onto
the plastic liner after use.
R
R
R
R
R
R
R
R
R
R
2296_IFU01_9608705.indd 19 17/07/2015 12:28
20
Instructions for use
g Press the body pads on the area you wish to apply
electrical stimulation, as shown on page 17, gently
pressing the adhesive side against the skin.
h Press the power button on the device or on the
remote control to turn REVITIVE Advanced on.
You will hear a beep and the display lights will light up.
The time will read 30 minutes and Intensity will
read 00.
To turn off REVITIVE at any time during operation,
press the power button on the device or remote
control.
i Press the (+) Intensity Control, one time, to
start stimulation.
Continue to increase the intensity until you can feel or
see the muscles contract and relax. You can set the
intensity between 1-99.
You can use the buttons on the device or remote
control.
Press the (+) button to increase the level.
Press the (–) button to decrease the level.
R
R
R
2296_IFU01_9608705.indd 20 17/07/2015 12:28
21
j Use an intensity that provides you with strong but
comfortable muscle contractions and note that the
intensity required may vary from day to day - eg
using it on 25 one day, does not necessarily mean you
will need to use if at 25 the next day. The required
intensity could be higher or lower than previous usage.
It is normal to feel tingling or varying sensations in
your calf muscles.
If you feel pain or discomfort - lower the intensity of
the body pads using either the (–) Intensity Control
on the control panel or the remote control.
k The Time display will start to count down in
minutes as REVITIVE Advanced cycles through its
program.
l When REVITIVE Advanced times out, the Time
Display reads 00 and you will hear three beeps, and
the device will switch itself off automatically.
m Ensuring that the device has switched itself off, then
gently peel the body pads from the skin.
Do not pull the body pads off the skin using the
body pad cords as this may damage the cords.
R
R
R
R
R
2296_IFU01_9608705.indd 21 17/07/2015 12:28
22
Instructions for use
n Replace the body pads onto its plastic liner after use.
o Unplug the body pad cord from the opening
on the device.
You do not need to detach the body pads from the
body pad cord.
R
R
R
R
R
2296_IFU01_9608705.indd 22 17/07/2015 12:28
23
STEP 5:
CLEANING AND STORING REVITIVE
a Press the power button and turn REVITIVE off, if needed.
b Wipe down the foot pads with a soft damp cloth.
Do not clean with chemicals.
Do not immerse REVITIVE Advanced in water.
c Store REVITIVE Advanced in a cool, dry and dust-free location.
Store out of direct sunlight.
d Place body pads back on the plastic liner.
e Store the body pads in a dry and ventilated location.
Store out of direct sunlight.
You do not have to detach the body pads from the body pad cord to store
them.
Replacing the Batteries
The remote control requires two AAA 1.5V batteries to operate.
Replacing the Body Pads
The body pads are reusable up to 20-30 applications. If the body pads
start to lose their adhesiveness, rub a few drops of water into the surface.
Replacement body pads can be obtained via www.revitive.com.au.
2296_IFU01_9608705.indd 23 17/07/2015 12:28
24
Troubleshooting
Problem Possible Cause Solution
REVITIVE Advanced is
on (lights illuminated
on the LED display)
but I cannot feel the
electrical stimulation
through the foot
pads.
Not placing both bare feet on the
foot pads at the same time.
Ensure that your feet are bare
and each foot is placed on each
of the foot pads at the same
time. Keep increasing the
intensity up to a maximum of 99
until you feel the stimulation.
Your feet may be dry. Moisturise the soles of your feet
to improve conductivity and
stimulation and try the procedure
again. You may also have to
increase the
intensity level.
You may be dehydrated. Drink plenty of water before
and after using the device. The
device uses your body to create
the electrical circuit. Water is an
excellent conductor of electricity
and if your body is less hydrated
(below 60%) then the stimulation
may be less. Therefore it is
important to always remain well
hydrated.
The
intensity level may be on
too low a setting.
This is a very safe device. Keep
increasing the
intensity level
towards 99 until you feel the
stimulation. You may find that
you have to increase the
intensity level as you get used to
the therapy. The aim is not to get
to 99 but to find a setting that is
comfortable for you.
Body pad cord is connected to
device.
Disconnect the body pad cord -
the foot pads will not work while
the body pad cord is plugged in.
If, having tried the solutions
above, you still cannot feel the
stimulation:
Test the device by placing one
hand across both foot pads at the
same time (The heel end of the
foot pads is easiest). With your
other hand, and starting from
zero, increase the intensity
level until you can feel the
stimulation. If you can feel the
stimulation through your hand
then the device is working. If
on 99 you still cannot feel the
stimulation then please contact
your authorised dealer.
2296_IFU01_9608705.indd 24 17/07/2015 12:28
25
Problem Possible Cause Solution
No power or lights to
REVITIVE Advanced
when it is switched
on.
AC Adaptor not switched on
at the electrical socket or AC
Adaptor not plugged into device
properly.
Check electrical socket power
is switched on and the AC
Adaptor is plugged into
the device correctly. If still
not working – contact your
authorised dealer.
REVITIVE Advanced is
not vibrating.
REVITIVE Advanced IS NOT
DESIGNED TO VIBRATE.
The IsoRocker is not
"rocking".
It is the muscles in your legs
that cause the "rocking",
THE ISOROCKER IS NOT
MECHANICAL.
The ISOROCKER will only rock
when increased to an intensity
which causes sufficient calf
muscle contraction. It may be
that you cannot comfortably
increase the intensity high
enough until you get used to the
sensation. It is important that
intensity is adjusted to a level
that is comfortable.
The device is too far in front
of you.
Sit with your knees at a 90
degree angle.
The IsoRocker system is not
enabled.
Ensure IsoRocker Disabler is
“flat”, in centre position (see
page 12).
My legs are aching
after treatment.
You may have the
intensity
on too high a setting and your
muscles are being overworked.
Leave adequate time after
each treatment to allow the
muscles to recover (just like after
vigorous exercise!). On your
next session start on a lower
setting (where you can feel the
mild electrical stimulation and it
is comfortable) and reduce the
duration until your muscles have
acclimatized to the stimulation.
When using the
IsoRocker on a hard
floor it makes a
tapping noise.
Incorrect positioning of the
device or too high an intensity
level.
Adjust the positioning of the
device or lower the intensity
level to reduce the device
tapping. Alternatively use a
floor mat under the device
to cushion the sound.
For more information including Frequently Asked Questions,
please visit www.revitive.com.au
2296_IFU01_9608705.indd 25 17/07/2015 12:28
26
Name of product REVITIVE Advanced
Model RMV
Frequency 1Hz – 50Hz
Output current Max 15mA
Weight 1.4kg
Dimensions (with IsoRocker enabled and disabled)
enabled: 355(W)x355(H)x70(D) mm
disabled: 355(W)x355(H)x85(D) mm
Power consumption 5W
AC adaptor CE Approved
Power source
Input (adaptor used)
Output
100-240V AC ( ), 50/60Hz, 0.18A
5V ( ) DC ,1.0A
Contraindications
This describes situations where you should not use the
REVITIVE Advanced
Warnings and Cautions
Make sure you understand these before using the REVITIVE
Advanced
Power
Time Remaining
Intensity Level
IsoRocker Disabler
Center Positive Polarity
Type BF medical electrical equipment
Class II medical electrical equipment double insulated
Technical Specifications
2296_IFU01_9608705.indd 26 17/07/2015 12:28
27
The Remote Control replicates the controls found on the device
Complies with European Medical Devices Directive (93/42/EEC)
The Waste Electrical and Electronic Equipment Directive
(WEEE Directive).
At the end of the product lifecycle, do not throw this product
into normal household garbage, but take it to a collection point
for the recycling of electronic equipment
Legal manufacturer of the device
Keep dry
Consult instructions for use
Device LOT and serial number including year (YYYY) and month
(MM) of manufacture can be found on the box and back of unit
Humidity and temperature limit for storage
After any exposure to hot or cold temperatures outside the
specified operating range of 10 – 40°C allow the product to
re-adjust to the recommended operating temperatures to
ensure continued product performance.
Indoor Use Only
Do not disassemble
Operating Frequencies
38 KH
z
Operating Range Distance
0 to 25m at horizontal
0 to 18m at +/- 30 degree angle
from the horizontal.
10°C
30%
40°C
90%
#YYYYMMXXXXX
LOT
2296_IFU01_9608705.indd 27 17/07/2015 12:28
28
Your international two year warranty
It is important to retain the retailer’s receipt as
proof of purchase. Staple your receipt to this
back cover for future reference.
Please quote the following information if the
product develops a fault. These numbers can
be found on the base of the product:
Model no: ............................................................
Lot no: .................................................................
All REVITIVE devices are individually tested
before leaving the factory. In the unlikely event
of any device proving to be faulty within 28 days
of purchase, it should be returned to the place
of purchase for it to be replaced.
If the fault develops after 28 days and within 24
months of original purchase, you should contact
your local distributor quoting model number
and LOT number on the product, or write to
your local distributor at the address shown.
You will be asked to return the product (in
secure, adequate packaging) to the address
shown with a copy of proof of purchase.
Subject to the exclusions set out below (see
Exclusions), the faulty device will then be
repaired or replaced and dispatched usually
within 14 working days of receipt.
If, for any reason, this item is replaced during
the 2 year warranty period, the warranty on the
new item will be calculated from the original
purchase date. Therefore, it is vital to retain
your original till receipt or invoice to indicate the
date of initial purchase.
To qualify for the 2 year warranty, the device
must have been used according to the
manufacturer’s instructions supplied.
EXCLUSIONS:
1 Actegy Ltd, manufacturer of REVITIVE
devices, shall not be liable to replace the
goods under the terms of the warranty
where:
The fault has been caused or is
attributable to accidental use, misuse,
negligent use or used contrary to the
manufacturer’s recommendations or
where the fault has been caused by
power surges or damage caused in
transit.
The device has been used on a voltage
supply other than that stated on the
product or used with a power adaptor
other than the one supplied with the
product.
Repairs have been attempted by persons
other than our service staff (or authorised
dealer).
The device has been used for hire
purposes or non-domestic use.
The device is second hand.
2 Actegy Ltd are not liable to carry out any
type of servicing work, under the warranty.
3 Accessories such as Electrode pads are not
covered by the warranty.
4 Batteries and damage from leakage are not
covered by the warranty.
5 This warranty does not confer any
rights other than those expressly set
out above and does not cover any claims
for consequential loss or damage. This
warranty is offered as an additional
benefit and does not affect your
statutory rights as a consumer.
To activate your free 2 year warranty please register your device at the
REVITIVE website (see warranty/guarantee card).
If you prefer you can also post your registration.
2296_IFU01_9608705.indd 28 17/07/2015 12:28
29
Your international two year warranty
AUSTRALIAN WARRANTY
This device is guaranteed for 2 years
against faulty material, components and
workmanship.
This warranty is in addition and does not
affect your statutory rights.
Proof of purchase must be produced for any
warranty benefit.
In the unlikely event of any device proving to
be faulty, securely pack and return the item
to the place of purchase accompanied by the
original receipt or invoice.
Our goods come with guarantees that
cannot be excluded under the Australian
Consumer Law. You are entitled to a
replacement or refund for a major failure and
for compensation for any other reasonably
foreseeable loss or damage. You are also
entitled to have the goods repaired or
replaced if the goods fail to be of acceptable
quality and the failure does not amount to a
major failure.
NOT COVERED BY THIS WARRANTY
(Australia only)
If the device has not been used in
accordance with the manufacturers’
recommendations or Instructions.
If the fault is deemed to be caused by
abuse, misuse, neglect, modifications or
improper use and or care.
Connection to incorrect voltage or used
with an incorrect power adaptor to that
stamped or supplied with the product.
Unauthorised repairs.
Device used other than for domestic
purposes.
Excluding accessories such as Electrode
body pads, gloves and bag.
Freight and insurance costs.
If for any reason this item is replaced during
the 2 year guarantee period, the guarantee
on the new item will be calculated from
original purchase date. Therefore it is vital
to retain your original receipt or invoice to
indicate the date of original purchase.
Actegy Ltd’s policy is to continually improve
quality design and product quality. The
company therefore reserves the right to
change any specifications or to carry out
modifications as deemed worthy at any time.
To activate your free 2 year warranty please register your device at the
REVITIVE website (see warranty/guarantee card).
If you prefer you can also post your registration.
2296_IFU01_9608705.indd 29 17/07/2015 12:28
30
Notes
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
2296_IFU01_9608705.indd 30 17/07/2015 12:28
31
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
.......................................................................................................................................
2296_IFU01_9608705.indd 31 17/07/2015 12:28
Copyright © 2015 Actegy Ltd. All rights reserved. ACTEGY® and REVITIVE™ and
Circulation Booster™ are registered trademarks of Actegy Ltd. The REVITIVE product is a
proprietary design and is protected by applicable design laws.
AW 2296_IFU01_9608705 PD 07.2015
Actegy Ltd
REFLEX, Cain Road
Bracknell, RG12 1HL
United Kingdom
Tel: +44 (0)845 871 5989
Country Distributors:
International and UK
Tel: +44 (0)845 871 5989
Australia
Actegy Pty Ltd
Unit 4 / 1 Newspaper Place
Maroochydore
QLD, 4558
Tel: 1800 505 108
New Zealand
Actegy Ltd
24B Moorefield Road
Johnsonville
Wellington 6037
Tel: 0800 484 325
®
2296_IFU01_9608705.indd 32 17/07/2015 12:28
32

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Revitive RMV- Advanced Performance bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Revitive RMV- Advanced Performance in de taal/talen: Engels als bijlage per email.

De handleiding is 3,7 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info