0
PELLET
0
DRAUGHT
The draught value is modified with keys P4
and P5 .The quantity of pellet used (the value
indicated during the change only indicates a
percentage value that acts on the default pa-
rameters set in the electronic board) can be
measured with keys P1 and P2.
N.B.: The number indicated while changing the parameters
refers only to a percentage value that acts on the default
parameters set in the electronic board.
In any case, these values must be changed if bad combustion
arises due to the purchase of different pellets from those used
when the stove was tested.
!
!
THIS FUNCTION IS EFFECTIVE ONLY IF. THE DUE
REGULATIONS HAVE BEEN MADE DURING THE IN-
SPECTION OF THE STOVE
9.6. Automatic loading of the screw
To automatically load the screw (when the stove is new the loading
screw is empty), proceed as follows:
1.
Remove and reset the electric supply of the stove using the general
switch on the back.
2.
The display will show FINAL CLEANING and then OFF.
3.
Press button P7, CLOCK SETTING MENU will appear.
4.
Press button P6: “SCREW 0” will appear.
THE SCREW IS IDLE
2000
150°
STATE 0
COCLEA 0
PRESS BUTTON P2 TO ACTIVATE AND P1 TO DEACTIVATE THE
SCREW
SCREW ACTIVATED
2000
150°
STATE 0
COCLEA
1
Repeat the operation several times until you can see the pellets fall
into the fire pot.
N.B.: This operation can be performed only if the stove is
OFF.
!
!
AFTER HAVING LOADED THE SCREW, EMPTY THE
FIRE POT INTO THE TANK BEFORE SWITCHING ON.
9.7. Switching on the stove
Before switching on the stove, proceed as follows:
1.
Insert the mains supply cable and activate the switch behind the
stove’s right-hand rear upright (see Fig. A).
Fig. A
2.
Place the switch on the back in position 1.
3.
Check that the appliance is connected to the flue.
4.
Load the tank (see par. 3.4).
5.
Load the screw (see par. 9.5).
6.
Press button P3 for 3 seconds.
At this point the stove will switch on.
The following messages will appear on the screen
LIGHT
WAIT FOR FLAME
FLAME PRESENT
WORKING
During the working phase, the following settings should be checked:
POWER SETTING as described in chapter 9.1
ROOM TEMPERATURE SETTING as described in chapter 9.3
PELLET/AIR MIX SETTING as described in chapter 9.4
9.8. How to associate the remote control to the stove
All input stoves are fitted with remote-control, radio-wave handsets
and a receiver located on the right-hand side of the stove. Some-
times, due to interference from other electrical household appliances
(microwave ovens, satellite decoders, mobile phones, cbs, .... ) the
connection between the stove and the handset may be interrupted
(no field). The following operations must be carried out to reinstate
the connection:
Switch the stove off.
Unplug the power lead.
Press the triangle keys 1 and 2 on the handset together for
about 3 seconds.
Using triangle key 2, select the frequency unit to be loaded
(select unit 0 , 1 , 2 , 3 ).
Reconnect the electricity by plugging in the power lead.
Press the red button.
If the operation is successful, UNIT LOADED 0, 1, 2, 3 will appear
on the handset.
9.9. Synthetic table of phases
PHASE
DESCRIPTION
FINAL CLEANING
The stove is switching off, the cooling phase is not yet completed
LIGHT
The glow-plug pre-heating phase has started, and the pellet starts to fall into the
re pot.
WAIT FOR FLAME
The pelle is ligted by the hot air passing trought the ignition candle
FLAME PRESENT
The pellets are loaded into the re pot
WORK
The ame is visibile in the re pot
MODULATION
WORKING
The ame is visible in the re pot
ECO STOP
The room temperature set has been reached
T ON
Comfort Climate activated, temperature set has been reached, the stove is off.
FAN WAITING FOR
START
The room sensor is off or an external thermostat has been connected
FAN WAITING FOR
RESTART
The stove is in the cooling DOWN:when stove is cooled down can start
automatically.
LIGHT WAITING FOR
RE-IGNITION
The switch ON when the dtove is warm started. The operation is same of phase ON
HOT SMOKE
The max temperature of smokes is reached: to reducefeeding pellets and air draft
at PT 01
OFF
The stove is off
!
!
IF THE “HOT SMOKE” SIGNAL IS DISPLAYED THIS
MEANS THAT THERE ARE PROBLEMS IN THE COM-
BUSTION AND THEREFORE YOU MUST CONTACT
YOUR LOCAL T.A.C. FOR ASSISTANCE.
10. MAINTENANCE
Before carrying out any maintenance operation on the stove, please
take the following precautions:
Make sure that all the parts of the stove are cold
Make sure that the ashes are completely extinguished
Make sure that the general switch is in the zero position (off)
Make sure that the plug is disconnected from the socket, thus avoid-
ing accidental contacts
23

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Ravelli-500

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Ravelli 500 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Ravelli 500 in de taal/talen: Duits, Engels, Frans, Italiaans, Spaans, Deens als bijlage per email.

De handleiding is 10,04 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info