Figure 10.1
HIGH
MED
LOW
Burn Rate
Air Control
Start-Up
Air Control
It is very important to reload your appliance while
enough lively hot coals remain in order to provide the
amount of heat needed to dry and rekindle the next load
of wood. It is best to open the Burn Rate Air and Start-
Up Air Controls before reloading. This livens up the coal
bed and reduces excessive emissions (opacity/smoke).
Open door slowly so that ash or smoke does not exit
appliance through opening. You should also break up
any large chunks and distribute the coals so that the
new wood is laid on hot coals.
Air quality is important to all of us, and if we choose to use
wood to heat our homes we should do so responsibly.
To do this we need to learn to burn our appliances in
the cleanest way possible. Doing this will allow us to
continue using our wood appliances for many years to
come.
2. Medium low burn setting:
- Burn Rate Air Control spring handle up to high position
for 5 minutes.
- Then activate the ACC timer system by pushing the
knob all the way back toward the appliance to “HI”
then pull forwards towards the front of the appliance
until the knob stops.
- At that point move the Burn Rate Air Control spring
handle to 1/8”-1/2” from the low setting.
3. Medium high burn setting:
- Burn Rate Air Control spring handle up to high position.
- Then activate the ACC timer system by pushing the
knob all the way back toward the appliance to “HI”
then pull forwards towards the front of the appliance
until the knob stops.
- At that point move the Burn Rate Air Control spring
handle to 1/2” – high.
4. High burn setting:
- Burn Rate Air Control spring handle up to high position
- Also activate ACC timer system knob pushed back to
the “HI” position.
Surface Thermometer is a Valuable Guide to Operation
A surface thermometer tells you when to adjust the air
control, and when to refuel, Figure 10.1.
For example, when the thermometer registers at least 450°F
(230°C) on the stove top after start-up you know the stove
is hot enough and it may be time to adjust the air control
if a sufcient ember bed has also been established. Note
that the stove will warm up much sooner than the chimney,
though; a warm chimney is the key to easy, effective stove
operation. When thermometer readings drop below 350°F.
(175°C) it’s time to adjust the air control for a higher burn
rate or to reload the stove. A temperature reading over
650°F. (340°C) is a sign to reduce the air supply to slow the
burn rate.
Use the following temperature ranges as a guide:
Readings in the 350°-500°F. (175°-260°C) range indicate
low to medium heat output.
500°-600°F. (260°-315°C) readings indicate medium
heat output.
Readings of 600°-650°F. (315-340°C) indicate high
heat output. Operating your wood stove continuously at
stove top temperatures higher than 650° F (340°C) may
damage your wood stove.
NOTE: The above information is provided as a guideline
only. Altitude and other circumstances may require
control adjustments to achieve the desired burn rates.
NOTE: Operate appliance on High Burn 45 minutes a
day to help keep ue/chimney clean.
NOTE: If using the optional blower, for burn rate settings
1-3, the blower shall be off for the rst 30 minutes and
then be operated in the high position at 30 minutes. For
high burn setting, blower may continue to be on full after
the loading of the fuel.
D. Burn Rates and Operating Efciency
For maximum operating efciency
This wood appliance has a manufacturer-set minimum
low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this
wood appliance in a manner inconsistent with operating
instructions in this manual.
Burn dry, well-seasoned wood.
Burn Rates
1. Low burn setting:
- Burn Rate Air Control spring handle up to high position
for 5 minutes.
- Then activate the ACC timer system by pushing the
knob all the way back toward the appliance to “HI”
then pull forwards towards the front of the appliance
until the knob stops (Figure 10.1).
- At that point close the Burn Rate Air Control by moving
the spring handle to the low setting.
Surface
Thermometer
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Quadra-Fire 5700 Step Top bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Quadra-Fire 5700 Step Top in de taal/talen: Engels als bijlage per email.

De handleiding is 6.15 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Quadra-Fire 5700 Step Top

Quadra-Fire 5700 Step Top Gebruiksaanwijzing - Français - 32 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info