572626
10
Verklein
Vergroot
Pagina terug
1/50
Pagina verder
STORAGE
Always store the unit in its carrying case in a dry, well-ventilated space. For
prolonged storage, remove the batteries.
TROUBLESHOOTING
Listed below are some potential problems that may occur when using the scope.
Carry out the recommended checks and troubleshooting steps in the order
listed. Please note that the table does not list all of the possible problems. If the
problem experienced with the scope is not listed, or if the suggested action
meant to correct it does not resolve the problem, please contact your seller.
Peculiarities of CCD array
CCD arrays employed in Pulsar digital night vision devices, feature high quality. However
certain pixels (or groups of pixels) with increased luminosity (lighter or darker) are allowed.
These defects can be seen when conducting observation not only in the nighttime but in the
day time too, especially if SumLight™ function is active. Presence of light and dark pixels and
other minor defects of a CCD array (up to 4%) are acceptable in accordance with regulations
of sensor producer.
Visibility on the screen of light pixels also depends on the type of CCD array, heating
temperature during operation.
PROBLEM
The riflescope will not turn on.
The reticle is blurred and cannot
be focused with the dioptre knob.
With a crisp image of the reticle,
the image of the observed target
that is at least 30 m away is
blurred.
The aiming point shifts after firing
rounds. The riflescope will not
focus.
The riflescope will not focus.
POSSIBLE CAUSE(s)
Batteries have been wrongly
installed.
Oxidized contact points in the
battery compartment due to
“leaky” batteries or contact points
becoming exposed
to a chemically-reactive solution.
The batteries are empty or
one of batteries is faulty.
The dioptre cannot be adjusted to
your eyesight.
Dust and condensate are
covering the outside optical
surfaces after the riflescope was
brought in from the cold into a
warm environment, for example.
The riflescope is not mounted
securely or the mount was not
fixed with thread sealant.
Wrong settings.
The riflescope cannot be started
with wireless remote control.
After the built-in laser IR
Illuminator is activated, you may
see a slightly grainy, non-uniform
pattern which does not impact
detection range and efficiency of
observation.
Rangefinder does not measure
distance.
The scope is used in day light at
long working distance.
Remote control is not activated.
Low battery.
This is normal for eye safe laser
illuminators.
In front of the receiver lens or
objective lens there is an object
that prevents signal transmission.
The unit is not held steadily when
measuring.
Distance to the object exceeds
400m.
Low reflection ratio (i.e. leaves of
trees).
СORRECTIVE ACTION
Reinstall the batteries with the
correct polarity orientation.
Clean the battery compartment,
focusing on the contacts.
Install fresh batteries.
If you wear prescription glasses with
a range of +/- 4, keep glasses on
when looking through the eyepiece.
Clean the lens surfaces with a
blower and soft lens cloth. Let the
riflescope dry by leaving it in a warm
environment for 4 hours.
Check that the riflescope has been
securely mounted, make sure that
the same type and calibre bullets are
being used as when the scope was
initially zeroed; if your riflescope was
zeroed during the summer, and is
now being used in the winter (or the
other way round), a small
displacement of the aiming point is
possible.
Adjust the riflescope according to the
instructions given in the Section 9
“OPERATION” and check the
surfaces of the eyepiece and
objective lenses and clean them if
necessary from dust, condensation,
frost, etc; to prevent fogging in cold
weather, apply a special anti-fog
solution.
Check focusing of the scope in night
conditions.
Activate the remote according to
instructions in section 16.
Install a new CR2032 battery.
This is not a defect.
Make sure that the lenses are not
blocked by your hand or fingers.
Do not stress the unit when
measuring.
Choose an object at a distance
longer than 400m.
Choose an object with a higher
reflection ratio.
16
17
The unit does not operate
on external power
supply.
Large measurement error.
Make sure your power supply
provides output voltage.
Make sure the central
pin of the external
power supply is intact.
Charge the power supply
(if required).
If it's necessary, unbend
the pin to ensure electric contact.
Inclement weather conditions
(rain, mist, snow).
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Pulsar Digisight LRF N850 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Pulsar Digisight LRF N850 in de taal/talen: Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 5,11 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info