632205
10
Verklein
Vergroot
Pagina terug
1/20
Pagina verder
1
Table of Content:
Chapter 1: Product Summary:
1.1 Technical Parameters…………..………….…………….…………….2
1.2 Package Contents….………………………………………….……….3
1.3 Function description………………………………………….……….3
Chapter 2: Equipment installation:
2.1 DIP switch settings…………………................................................5
2.2 Dome camera structure diagram……………………………….……7
2.3 Bracket installation diagram...……………………………………….8
Chapter3: System OSD menu settings:
3.1 Power-on self-test………….……………..………………………..….8
3.2 Preset point setting and calling…………..……………………..….8
3.2.1 Set preset points………….……………….………..………………..9
3.2.2 Call preset points…….…………………….………….……………..9
3.3 Preset point function table.………………….……………………….9
3.4 <MAIN MENU>………….…………………………..………………….10
3.5 <SYSTEM INFORMATION>.…………………….………………..…11
3.6 <ADDR SETTING>………………..……………………….………..…11
3.7 <MOTION>……………………………………….………………........12
3.7.1 <SET FRAME SCAN>………………………………….……………12
3.7.4 <POWER UP>……………..…………………….…………...………13
3.7.5 <PARK ACTION>……………………………………...………..……13
3.8 <PATTERNS>…..............................................................................14
3.8.1 <PROGRAM PATTERN>.............................................................14
3.9 <CAMERA >(Lens) settings menu................................................15
3.10 <CRUISE> (preset points, cruise settings) menu….…..……....15
3.11 <IR SETTING>...............................................................................16
3.12 <DISPLAY SETUP>.......................................................................16
Chapter 4: Troubleshooting:
4.1 Troubleshooting Table……………..………………..…….....………17
2
Chapter 1:Product Summary:
1.1 Technical Parameters:
Model number 4" High Speed Mini Dome Camera
Optical focus 10X
Image sensor 1/3"CCD
Signal mode PAL/NTSC
Resolution 650TVL
Optical focus
Manual/Auto, high performance DSP to utilize high
continuous focusing function.
Presets 256
Pattern scan 4groups,each can record 100 actions
Cruise scan
Up to 30 presets cruise with independent dwell
duration.
Other scan
Supports Horizontal scan, Deuce area scan and
random scan
Rotation range
Horizontal 360°unlimited rotation, Vertical 180°, auto
flip
Rotation speed Horizontal & Vertical Min 0.01° Max 300°/s.
Protocol PELCO-D and PELCO-P
OSD Full screen menu
Temperature
control system
Optional
Power supply DC12V
Ball cover
dimension
4 inch optical glass cover (Non-IR model only)
Material Aluminum shell
IP Rating IP66 (Non-IR Model Only)
Work
environment
-20~+50(select temperature control accessories),
<95%RH
3
1.2 Package Contents:
1. Speed Dome Camera – 1 Pcs
2. Wall Bracket – 1 Pcs
3. Ceiling Bracket – 1 Pcs
4. Power Supply – 1 Pcs
5. User Manual – 1 Pcs
6. Installation Accessories – Lot.
1.3Main Functions Description:
1. Set address coding, baud rate, control protocol:
Each command transmitted to the camera has its own address coding,
baud rate and control protocol. APTZ camera will respond only if its own
address coding, baud rate and control protocol matches the ones of the
command. In order to set the camera address coding, baud rate and
control protocol settings please refer to the DIP settings.
2. Auto speed matching to focal length technical:
Based on user-friendly design, the camera's intelligent response
mechanism will be generate different tracking speeds according to the
proximity of the focal length of the camera. The camera will automatically
adjust the horizontal and vertical tracking speed, so that manual operation
is simpler and track targets become easier.
4. Auto Flip:
When the lens is pulled all the way down (vertically) by the operator, the
lens will auto-rotate 180° and continue the move turning up immediately
after the 90°, this allows a direct watch to the back of the scene in order to
achieve the full 180° continuous vertical surveillance.
5. Set and call preset position:
Preset function stores a given state of the ball. The PTZ memory will store
the horizontal angle; tilt angle and camera lens focal length. "Calling" these
parameters will quickly send the PTZ ball to the saved location. The
operator can quickly and easily store and call preset points by using a PTZ
keyboard, infrared controller or other equipment such as DVR which
supports PTZ feature. The PTZ supports up to 256 preset points.
4
6. Lens Control:
(1) Zoom control
Users can control the PTZ lens in order to adjust the zoom level of the
camera and get wide/narrow view according to the scene.
(2) Focus Control
System default is auto-focus. The object in center of the screen will be the
subject of focus. In exceptional circumstances the user can manually
adjust the focus in order to maintain a clear picture.
When in momentarily manual focus state (achieved by Focus +/- controls
on the control unit), any shift of the camera by user or preset call will
reinstate the auto-focus.
In the following situations the camera lens may not autofocus on the
desired objective:
a. Target is not in the screen center;
b. The target has different parts that are both near and far.
c. The target is light objects such as neon lighting, spotlights and other
luminous items;
d. Target is behind interfering layer (Such as droplets or glass).
e. Large monotone area targets, such as walls.
f. Large area targets, such as walls;
g. Target is located in extremely dark/foggy environment.
7. Aperture Control:
Users can control the lens in order to manually adjust the aperture size to
get the required picture brightness.
8. Backlight Compensation:
When the backlight compensation function is on, the camera will disregard
bright areas in the scene and will open the shutter further more to light up
dark areas in the scene.
9. White Balance:
The camera will reproduce color shadings according to the changes in
ambient light in order to achieve true color shades in any conditions.
5
10. Night Mode (color / Black & White conversion):
Cameras with night mode, automatic color / monochrome conversion mode,
in accordance with changes in ambient light automatic conversion CCD
illumination. Such as: adequate lighting during the day due to the use of
general illumination to ensure colorful images. In the night illumination can
be automatically changed to black and white images show a clear interest.
11. Cruise:
Cruise can be built from several preset points. The presets for this speed
dome can be configured in consecutive order only (you may skip a
non-relevant preset, but you cannot change the order of the called
presets).Dwell durations can be configured according to the needs. The
cruise can be activated using the OSD or the RS-485 controller.
12. Pattern scanning:
Pattern scan will record any movement of the camera's ball in order to
make a consecutive scan with special characteristics.
13. Continuous scan:
Continuous horizontal scan with adjustable height and speed. It can be
triggered in power-up or RS-485 controller.
14. Random Scan:
Random horizontal scan with adjustable height and speed; unlike the
continuous scan, the random scan will shift the camera left and right and
dwell in random points. It can be triggered in power-up, by OSD or RS-485
controller.
15. Area scan
Continuous horizontal scan with adjustable height, speed and left/right
borders which the camera is confined to. It can be triggered in power-up,
by alarm or RS-485 controller.
Chapter 2 Equipment installation:
2.1DIP switch setting:
The four channel DIP switch is the baud rate and the control protocol switch.
The eight channels DIP switch is
the address setting switch.
6
DIP switch to “ON” means to “1”,DIP switch to "OFF" means "0".
The baud rate and control protocol as the following table:
NO. 1 2 3 4
Baud rate
(BPS
OFF OFF PELCO-P
ON OFF PELCO-D
OFF ON PELCO-D/P
ON ON PELCO-D/P
Control
Protocol
OFF OFF 9600
ON ON 9600
OFF ON 4800
ON OFF 2400
8-bit DIP switch is used to set the camera's address coding. Address set
binary mode can be set to a total of 256 different dome camera address
coding, see coding table address.
Camera
address
Camera address coding form
1 2 3 4 5 6 7 8
0 OFF OFF OFF OFF OFF OFF OFF OFF
1 ON OFF OFF OFF OFF OFF OFF OFF
2 OFF ON OFF OFF OFF OFF OFF OFF
3 ON ON OFF OFF OFF OFF OFF OFF
4 OFF OFF ON OFF OFF OFF OFF OFF
5 ON OFF ON OFF OFF OFF OFF OFF
6 OFF ON ON OFF OFF OFF OFF OFF
7 ON ON ON OFF OFF OFF OFF OFF
8 OFF OFF OFF ON OFF OFF OFF OFF
9 ON OFF OFF ON OFF OFF OFF OFF
10 OFF ON OFF ON OFF OFF OFF OFF
11 ON ON OFF ON OFF OFF OFF OFF
12 OFF OFF ON ON OFF OFF OFF OFF
246 OFF ON ON OFF ON ON ON ON
247 ON ON ON OFF ON ON ON ON
7
248 OFF OFF OFF ON ON ON ON ON
8
2.2 Dome camera structure diagram:
Figure 1 Figure 2
2.3 Bracket installation diagram
Figure 3
9
Figure 4
Chapter 3 System OSD menu settings:
3.1Power-On Self-Test:
When power is connected to the dome camera, the camera will move in
horizontal and vertical directions to confirm that motors and belts are in order.
The screen will show system-related information.
PTOL PELCO-D
COMM 2400N81
ADDR 1
Display: PELCO-D protocolBaud Rate 2400Address code 1
3.2Preset point setting and calling:
3.2.1 Set Preset points:
(1) Make sure the correct camera is selected in your controller.
(2) Adjust pan, tilt and zoom to the desired location.
(3) Press the required preset number + PRESET* to preserve the scene
preset parameters.
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Provision ISR LC-10 IR bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Provision ISR LC-10 IR in de taal/talen: Engels als bijlage per email.

De handleiding is 0,33 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info