b) Check the  spring function  of  the re-
tracting blade guard.If the retract ing 
blade guard and the spring do not op-
erate properly, have the machine serv-
iced before using. The retracting blade
guard may operate sluggish due to dam-
aged parts, gummy deposits or build-up of
chips/sawdust.
c) Only pull back  the  retracting  blade 
guard manually for special cuts,such as 
“plunge andbevel cuts”.Pull back the 
retracting blade  guard  with the  pull-
backlever and release it as soon as the 
saw blade has penetrated the work. For
all other sawing jobs, the re tracting blade
guard must operate auto matically.
d) Do not place down the sawon a work 
bench  or  the  ground  without  the re-
tracting blade guard covering thesaw 
blade. An unprotected, coasting saw blade
will move the saw in the op posite direction
of the cut, cutting what ever is in its path.
Pay attention to the run-on period of the
saw.
e) Use the  matching  riving knife  for the 
saw blade being worked with. The riv-
ing knife must be wider than the thick ness
of the blade back, but thinner than the kerf
width of the saw blade.
f) Adjust  the  riving  knife  as  described 
in the operating instructions. Incor rect
width, position and alignment can be the
cause that the riving knife does not effec-
tively prevent kickback.
g) Always  use  the  riving knife, except 
whenperforming plunge cuts. After the
plunge cut, mount the riving knife again.
The riving knife interferes when performing
plunge cuts and can lead to kickback.
h) In order for the riving knife to be ef-
fective, it  must be  located  in the  cut. 
For short cuts, the riving knife is ineffec tive
for the prevention of kickback.
i) Do not operate the saw with a bent riv-
ing  knife.  Even a minor malfunction can
lead to sluggish retraction of the re tracting
blade guard.
5.5 Emission levels
Levels determined in accordance with EN 60
745 are typically:
Sound pressure level L
PA
= 102 dB (A)
Noise level L
WA
= 113 dB (A)
Uncertainty K = 3 dB
CAUTION
The  noise  created  during  work  may 
damage hearing. 
Use hearing-protective aids!
Vibration emission value a
h
(vector sum for
three directions) and uncertainty K meas-
ured in accordance with EN 60 745: 3.1 m/s
2
Uncertainty K = 1.5 m/s
2
.
The emission values speci ed (vibration, noi-
se) were measured in accordance with the test
conditions stipulated in EN 60 745 and are
intended for machine comparisons. They are
also used for making preliminary estimates re-
garding vibration and noise loads during ope-
ration.
The emission values speci ed refer to the
main applications for which the power tool
is used. If the electric power tool is used for
other applications, with other tools or is not
maintained suf ciently prior to operation, ho-
wever, the vibration and noise load may be
higher when the tool is used.
Take into account any machine idling times
and downtimes to estimate these values more
accurately for a speci ed time period. This
may signi cantly reduce the load during the
machine operating period.
6  Commissioning and 
Operation 
    WARNING
Riskof injury, if the tools areused with 
wrong supply power. 
The voltage specications on the rating plate
must correspond with the mains voltage.
Equipment marked with 230 V can also be con-
nected to 220 V / 240 V.
Check that the plug type is the same as the
socket type.
Adjustment of the riving knife 
   WARNING
Risk of injury,  if the riving knife is not 
correctly adjusted. 
The riving knife [1-11] must always be used
for safety reasons. The riving knife prevents
the saw blade from becoming jammed when
making lengthwise cuts.
Loosen screw [1-12], adjust the riving knife
[1-11] and retighten the screw (see gure).
1-11
1-12
Check the function of the swinging guard [1-9].
Switching On/Off 
Switching On: 
Press the safety button [1-14].
Press the on-off switch [1-13] and hold depressed.
Note: The on-off switch cannot be locked on.
Switching Off: 
Release the on-off switch [1-13].
7  Adjustment 
    WARNING
Risk of electric injury. 
Before any manipulation with the tool make
sure to unplug the mains socket outlet.
7.1Electronic Motor Control
Soft start 
The electronically-controlled soft start en-
sures that the tool starts without jerking and
requires only a small starting current (weaker
fusesrequired).
Constant speed 
The motor speed is electronically stabilised.
This enables a constant cutting speed even
under a heavy load.
Overload protection 
In cases of extreme overload (rip cutting, use
of blunt saw blades) the power consumption
may considerably exceed the permissible rated
value. In this case an electronic overload de-
vice protects the motor from burning out. The
motor is hereby switched of by an “electronic
safety clutch” and re-starts as soon as the load
is removed.
Temperature protection 
Extreme overload in continuous operation
causes the motor to heat up. An electronic tem-
perature monitoring device is tted to prevent
overheating (motor burn-out). The electronic
safety device switches the motor off before the
motor is able to reach a critical temperature.
After a cooling period of approx. 3–5 minutes
the machine is once again ready for operation
and can run at full load. The cooling period can
be greatly reduced if the machine is running
(idling or recovery speed).
7.2 Cutting Depth Adjustment 
Release the locking lever [1-16].
Set the required depth on the cutting
depth scale [1-15].
Raise: smaller cutting depth
Lower: larger cutting depth
Re-tighten the clamping lever [1-16].
To achieve the best cutting results, the
saw blade should protrude from the
material by no more than 3 mm.
7.3 Cutting Angle Adjustment 
Release the cutting angle locking lever at [1-7]
and [1-18].
Set the cutting angle as required using the
scale [1-19]. (The scale is calibrated in in-
crements).
Re-tighten the cutting angle locking lever at
[1-7] and [1-18].
   WARNING
The maximum cutting depth is reduced 
for bevel cuts. 
11

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Protool CSP132 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Protool CSP132 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools, Deens, Zweeds, Noors, Fins als bijlage per email.

De handleiding is 2,59 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info