POWXG90425 EN
Copyright © 2018 VARO P a g e | 6 www.varo.com
▪ Attach the hose connector (with built-in filter) to pressure washer.
▪ Connect the garden hose with a standard quick coupling
6.2 Mounting of high pressure hose (Fig. 4)
1. Attach the high pressure hose to the trigger gun.
2. Detach the high pressure hose by pressing the button (B)
6.3 Mounting of lance and nozzle
1. Push the lance into the trigger gun
2. When inserted turn it. Caution: Make sure the lance is properly fixed to the gun
3. Attach the nozzles. Push it powerful onto the lance. Check before activating the trigger
that the nozzle is properly fixed.
6.4 Water connection
An ordinary 1/2" garden hose of min. 10 m and max. 25 m will be suitable.
IMPORTANT! Only use water without any impurities. If there is a risk of
sand particles in the inlet water (i.e. from your own well), an additional filter
should be mounted.
1. Let the water run through the water hose before connecting it to the machine to prevent
sand and dirt from penetrating the machine. Note: Check that the filter is fitted in the
water inlet pipe and that it is not clogged up.
2. Connect the water hose to the water supply by means of the quick connector (inlet water,
max. pressure: 12 bar, max. temperature: 50°C).
3. Turn on the water.
6.5 Start/stop of the machine
The trigger gun and lance is affected by a thrust during operation - therefore always hold it
firmly with both hands.
IMPORTANT: Point the nozzle at the ground.
This high pressure cleaner is equiped with an automatically sart/stop
system, based on waterpressure.
1. Check that the machine is in upright position. NOTE: Do not place the machine in high
grass!
2. Release the trigger lock
3. Activate the trigger of the trigger gun and let the water run until all air has escaped from
the water hose.
4. Turn the Start/stop switch to the right
5. Activate the trigger of the trigger gun.
6. Always adjust the distance and thus the pressure of the nozzle to the surface, which is to
be cleaned.
Do not cover the machine during operation or use it in a room without adequate ventilation!
NOTE: If the machine is left or not used for 5 minutes, it must be switched off on the start/stop
switch (4) "O":
1. Turn the start/stop switch to the left "O".
2. Disconnect the electrical plug from the socket.
3. Shut off the water supply and activate the trigger of the trigger gun to relieve the machine
of pressure.